9/16

 

Operation

 

 

Button

 

Descriptions

 

 

 

 

Power

 

ON/OFF

 

the

 

meter

 

MAX/MIN

 

Select

 

MAX/MIN/AVG

 

P

 

M

 

 

Toggle

 

between

 

P1

 

and

 

P2

 

H

 

 

Freeze

 

the

 

readings

 

on

 

the

 

display

 

T

 

M

 

 

Toggle

 

between

 

T1

 

and

 

T2

 

(The

 

middle

 

display

 

shows

 

the

 

temperature

 

plus

 

the

 

offset.

 

See

 

the

 

SETUP

 

section

 

to

 

adjust

 

the

 

offset

 

values

 

for

 

T1

 

and

 

T2)

 

/SET

  

Press

 

once

 

to

 

power

 

ON/OFF

 

backlight

 

or

 

press

 

for

 

3

 

seconds

 

to

 

enter/exit

 

setup

 

mode

 

/UNITS

 

Change

 

the

 

pressure

 

units,

 

scroll

 

though

 

setup

 

options,

 

or

 

increase

 

the

 

displayed

 

setting

 

°F/°C

 

 

 

Change

 

the

 

temperature

 

units,

 

scroll

 

through

 

setup

 

options,

 

or

 

decrease

 

the

 

displayed

 

setting

 

 

 

Press

 

one

 

time

 

to

 

enter

 

setup

 

option.

 

Press

 

two

 

times

 

to

 

store

 

the

 

displayed

 

setting

 

into

 

memory

 

Display

 

Backlight

 

To

 

turn

 

the

 

display

 

backlight

 

ON,

 

momentarily

 

press

 

the

 

backlight

 

 

button.

 

To

 

turn

 

the

 

backlight

 

off

 

press

 

the

 

backlight

 

 

button

 

one

 

more

 

time.

 

 

Data

 

Hold

 

To

 

freeze

 

a

 

displayed

 

reading

 

on

 

the

 

LCD,

 

press

 

the

 

HOLD

 

button

 

one

 

time

 

(the

 

HOLD

 

icon

 

will

 

appear

 

on

 

the

 

bottom

 

left

 

portion

 

of

 

the

 

LCD).

 

To

 

exit

 

HOLD,

 

press

 

the

 

HOLD

 

button

 

again.

 

 

Units

 

of

 

Measure

 

The

 

currently

 

selected

 

unit

 

of

 

measure

 

is

 

shown

 

below

 

the

 

measurement

 

value

 

on

 

the

 

top

 

sections

 

of

 

the

 

meter’s

 

LCD.

 

To

 

change

 

the

 

unit

 

of

 

measure,

 

press

 

the

 

/UNITS

 

button

 

until

 

the

 

desired

 

unit

 

of

 

measure

 

appears.

 

 

Displaying

 

Pressure

 

Press

 

Unit

 

button

 

to

 

scroll

 

through

 

available

 

pressure

 

units

 

of

 

measure.

 

Press

 

P

 

M

 

button

 

to

 

toggle

 

between

 

P1,

 

P2,

 

P1

P2

 

readings.

 

 

Displaying

 

Temperature

 

Press

 

unit

 

button

 

to

 

select

 

C/F.

 

Press

 

T

 

M

 

button

 

to

 

toggle

 

between

 

T1,

 

T2,

 

T1

T2

 

readings.

 

The

 

display

 

shows

 

dashes

 

(

‐ ‐ ‐

)

 

when

 

there

 

is

 

no

 

thermocouple

 

connected.

 

The

 

display

 

shows

 

“OL”

 

when

 

the

 

temperature

 

being

 

measured

 

is

 

outside

 

the

 

thermocouple

 

range.

 

Содержание HD780

Страница 1: ...USER MANUAL Heavy Duty Manifold Pressure Gauge Model HD780 Additional User Manual Translations available at www extech com...

Страница 2: ...sit our website www extech com to check for the latest version of this User Manual Translations Product Updates Customer Support and Product Registration Features Measures psi kPA inHg cmHg bar plus T...

Страница 3: ...splay 3 SET Button 4 UNITS Button 5 ENTER Button 6 F C Button 7 P P1 P2 selection M mode Button 8 MAX MIN Button 9 H Hold Button 10 T T1 T2 selection M mode Button 11 POWER Button RIGHT SIDE VIEW 1 T2...

Страница 4: ...ery compartment Back DISPLAY 1 P1 P2 and P1 P2 Pressure 2 Pressure units 3 T1 T2 T1 T2 Temperature 4 Hold icon 5 Setup icon 6 MAX MIN AVG indicators 7 Ambient Temperature 8 Auto power off symbol 9 Pow...

Страница 5: ...ht ON momentarily press the backlight button To turn the backlight off press the backlight button one more time Data Hold To freeze a displayed reading on the LCD press the HOLD button one time the HO...

Страница 6: ...old the SET button for three seconds to enter the Setup Mode Momentarily pressing the or buttons will cycle throughout the functions Press to select the desired function Setup is disabled in MIN MAX m...

Страница 7: ...a DC 9V Power Adapter The meter will be permanently powered ON when the DC adapter is used as the power supply the power button function is disabled Safety Please dispose of batteries responsibly nev...

Страница 8: ...ermocouple T1 T2 Temperature 60 C to 537 0 C 76 F to 999 9 F 0 1 0 15 rdg 1 0 C 0 15 rdg 1 8 F Ambient Temperature Sensor Type NTC 0 C to 50 0 C 32 0 F to 122 0 F 0 1 1 0 C 2 0 F General Specification...

Отзывы: