Maintenance

 

 
 

1.

 

Rear

 

cover

 

2.

 

Battery

 

compartment

 

3.

 

Fuse

   

 

 
 
 
 
 
 

Fuse

 

Replacement

 

1.

 

Disconnect

 

the

 

test

 

leads

 

from

 

the

 

instrument.

 

2.

 

Remove

 

the

 

rear

 

cover

 

by

 

removing

 

the

 

two

 

screws.

  

3.

 

Remove

 

and

 

replace

 

the

 

fuse

 

with

 

a

 

new

 

one

 

of

 

the

 

same

 

value

 

and

 

size

  

0.5A/500V,

 

(5

 

x

 

20mm).

 

4.

 

Replace

 

and

 

secure

 

the

 

rear

 

cover.

 

 

Battery

 

replacement

 

When

 

“Battery

 

Low”

 

appears

 

on

 

the

 

display,

 

replace

 

the

 

batteries.

 

1.

 

Disconnect

 

the

 

test

 

leads

 

from

 

the

 

instrument

 

and

 

remove

 

the

 

rear

 

cover

 

and

 

the

 

batteries.

 

2.

 

Replace

 

with

 

eight

 

1.5V

 

AA

 

batteries,

 

taking

 

care

 

to

 

observe

 

correct

 

polarity.

 

3.

 

Reinstall

 

battery

 

holder

 

and

 

battery

 

cover.

 

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Cleaning

 

 

WARNING

:

 

To

 

avoid

 

electrical

 

shock

 

or

 

damage

 

to

 

the

 

meter,

 

do

 

not

 

allow

 

water

 

inside

 

the

 

case.

 

Periodically

 

wipe

 

the

 

case

 

with

 

a

 

damp

 

cloth

 

and

 

detergent,

 

do

 

not

 

use

 

abrasives

 

or

 

solvents.

 

1

2

3

www.

.com

[email protected]

1.800.561.8187

Содержание GRT350

Страница 1: ...User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www extech com www com information itm com 1 800 561 8187 ...

Страница 2: ...visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features Microprocessor controlled with advanced safety features Two line LCD display Auto Ranging Earth resistance testing with three ranges 0 20Ω 0 200Ω 0 2kΩ Earth voltage measuring range of 0 300Vac Automatic C current spike check Automatic P potential s...

Страница 3: ...maximum Ambient temperature 0 40 C Observe the International Electrical Symbols listed below Double insulation This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Earth ground terminal Equipment complies with current EU directives W...

Страница 4: ...d connection 2 P1 terminal Green test lead connection 3 P2 terminal Yellow test lead connection 4 C2 terminal Red test lead connection 5 Display 6 Rc LED 7 Rp LED 8 Save button 9 Cursor buttons 10 Cursor buttons 11 ESC button 12 Power button 13 TEST STOP button www com information itm com 1 800 561 8187 ...

Страница 5: ...th voltage will appear on the display if it is present 6 Press SAVE to save the measurement in Log memory 7 Press ESC to return to the Select Function display Measurement Considerations Two terminal testing of earth resistance is appropriate for most general purpose testing in normally conductive soil However two terminal measurements include test lead and contact resistance in the measurement and...

Страница 6: ...he soil The distance between electrodes must be 5 to 10m 16 to 32 Four terminal earth resistance measurements 1 2 MAX AC 300V H S E ES P2 C2 C1 P1 3 1 Earth electrode rod under test 2 Potential spike 3 Current spike Three terminal earth resistance measurements 1 2 MAX AC 300V H S E ES P2 C2 C1 P1 3 1 Earth electrode rod under test 2 Potential spike 3 Current spike Two terminal earth resistance mea...

Страница 7: ...arth resistance is greater than 2000Ω Earth Resistivity Testing ρ Wenner 4 point method Insert the four electrodes at equal distances and in a straight line at an interval of 1 to 30m 3 3 to 32 3 apart The depth should be 5 or less the distance between the electrodes For example if the distance between the electrodes is 5m 16 the electrodes should be inserted to a depth of 25cm 10 500cm x 5 25cm N...

Страница 8: ...l display on the screen 4 Press the or arrow button to scroll through the saved data 5 Press ESC to get back to the Select Function display LOG Clear 1 Press the ON OFF button and wait for the Select Function screen to appear 2 Press the button and select LOG Clear 3 Press the TEST STOP button Are you sure will display on the screen 4 Press the TEST STOP button to clear the log data Successful wil...

Страница 9: ... correct polarity 3 Reinstall battery holder and battery cover Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligate...

Страница 10: ...ead 5 m 16 ft Black lead 10m 32 ft Yellow lead 10m 32ft Red lead 15m 49ft Temperature Humidity Operating 0 to 50 C 32 to 122 F 80 R H Storage 10 to 60 C 14 to 140 F 80 R H Altitude 2000m 6500 max Power Source 1 5V AA x 8 batteries Dimensions 250 L x 190 W x 110 D mm 9 84 x 7 5 x 4 33 Weight Approx 1430g batteries installed Fuse 500mA 500V 5 x 20mm fast blow ceramic type Safety Standards CAT IV 300...

Отзывы: