GRT350

en

GB_v1.3

   

12/16

 

8

Save

 

Function

 

The

 

meter

 

permits

 

saving

 

measurements

 

in

 

up

 

to

 

200

 

memory

 

locations.

 

When

 

a

 

test

 

has

 

completed,

 

press

 

the

 

SAVE

 

button

 

to

 

store

 

the

 

measured

 

data.

  

 

The

 

display

 

will

 

show

 

the

 

location

 

number

 

of

 

the

 

saved

 

data.

    

“SAVE

 

###”

 

 

 

LOG

 

Display

   

1.

 

Press

 

the

 

ON/OFF

 

button

 

and

 

wait

 

for

 

the

 

“Select

 

Function”

 

screen

 

to

 

appear.

 

2.

 

Press

 

the

 

 

button

 

and

 

select

 

“LOG

 

Display”.

 

3.

 

Press

 

the

 

“TEST/STOP”

 

button.

 

The

 

log

 

number

 

will

 

display

 

on

 

the

 

screen.

 

4.

 

Press

 

the

 

"

"

 

or

 

"

"

 

arrow

 

button

 

to

 

scroll

 

through

 

the

 

saved

 

data.

 

5.

 

Press

 

ESC

 

to

 

get

 

back

 

to

 

the

 

“Select

 

Function”

 

display.

 

 

 

LOG

 

Clear

 

1.

 

Press

 

the

 

ON/OFF

 

button

 

and

 

wait

 

for

 

the

 

“Select

 

Function”

 

screen

 

to

 

appear.

 

2.

 

Press

 

the

 

 

button

 

and

 

select

 

“LOG

 

Clear”

 

3.

 

Press

 

the

 

“TEST/STOP”

 

button.

 

“Are

 

you

 

sure?”

 

will

 

display

 

on

 

the

 

screen.

 

4.

 

Press

 

the

 

“TEST/STOP”

 

button

 

to

 

clear

 

the

 

log

 

data.

 

“Successful!”

 

will

 

display

 

on

 

the

 

screen.

 

5.

 

Press

 

the

 

“TEST/STOP”

 

button

 

to

 

verify

 

that

 

the

 

data

 

log

 

is

 

clear.

 

“No

 

Log

 

data”

 

will

 

display

 

on

 

the

 

screen.

 

6.

 

Press

 

ESC

 

to

 

get

 

back

 

to

 

the

 

“Select

 

Function”

 

display.

 

 

www.

.com

[email protected]

1.800.561.8187

Содержание GRT350

Страница 1: ...User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www extech com www com information itm com 1 800 561 8187 ...

Страница 2: ...visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features Microprocessor controlled with advanced safety features Two line LCD display Auto Ranging Earth resistance testing with three ranges 0 20Ω 0 200Ω 0 2kΩ Earth voltage measuring range of 0 300Vac Automatic C current spike check Automatic P potential s...

Страница 3: ...maximum Ambient temperature 0 40 C Observe the International Electrical Symbols listed below Double insulation This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Earth ground terminal Equipment complies with current EU directives W...

Страница 4: ...d connection 2 P1 terminal Green test lead connection 3 P2 terminal Yellow test lead connection 4 C2 terminal Red test lead connection 5 Display 6 Rc LED 7 Rp LED 8 Save button 9 Cursor buttons 10 Cursor buttons 11 ESC button 12 Power button 13 TEST STOP button www com information itm com 1 800 561 8187 ...

Страница 5: ...th voltage will appear on the display if it is present 6 Press SAVE to save the measurement in Log memory 7 Press ESC to return to the Select Function display Measurement Considerations Two terminal testing of earth resistance is appropriate for most general purpose testing in normally conductive soil However two terminal measurements include test lead and contact resistance in the measurement and...

Страница 6: ...he soil The distance between electrodes must be 5 to 10m 16 to 32 Four terminal earth resistance measurements 1 2 MAX AC 300V H S E ES P2 C2 C1 P1 3 1 Earth electrode rod under test 2 Potential spike 3 Current spike Three terminal earth resistance measurements 1 2 MAX AC 300V H S E ES P2 C2 C1 P1 3 1 Earth electrode rod under test 2 Potential spike 3 Current spike Two terminal earth resistance mea...

Страница 7: ...arth resistance is greater than 2000Ω Earth Resistivity Testing ρ Wenner 4 point method Insert the four electrodes at equal distances and in a straight line at an interval of 1 to 30m 3 3 to 32 3 apart The depth should be 5 or less the distance between the electrodes For example if the distance between the electrodes is 5m 16 the electrodes should be inserted to a depth of 25cm 10 500cm x 5 25cm N...

Страница 8: ...l display on the screen 4 Press the or arrow button to scroll through the saved data 5 Press ESC to get back to the Select Function display LOG Clear 1 Press the ON OFF button and wait for the Select Function screen to appear 2 Press the button and select LOG Clear 3 Press the TEST STOP button Are you sure will display on the screen 4 Press the TEST STOP button to clear the log data Successful wil...

Страница 9: ... correct polarity 3 Reinstall battery holder and battery cover Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligate...

Страница 10: ...ead 5 m 16 ft Black lead 10m 32 ft Yellow lead 10m 32ft Red lead 15m 49ft Temperature Humidity Operating 0 to 50 C 32 to 122 F 80 R H Storage 10 to 60 C 14 to 140 F 80 R H Altitude 2000m 6500 max Power Source 1 5V AA x 8 batteries Dimensions 250 L x 190 W x 110 D mm 9 84 x 7 5 x 4 33 Weight Approx 1430g batteries installed Fuse 500mA 500V 5 x 20mm fast blow ceramic type Safety Standards CAT IV 300...

Отзывы: