Maintenance 

WARNING

:  To avoid electric shock, disconnect the test leads from any source of voltage 

before removing the back cover or the battery or fuse covers. 

 

WARNING: 

To avoid electric shock, do not operate your meter until the battery and fuse 

covers are in place and fastened securely. 

This MultiMeter is designed to provide years of dependable service, if the following care 
instructions are performed: 

1. 

KEEP THE METER DRY

. If it gets wet, wipe it off. 

2. 

USE AND STORE THE METER IN NORMAL TEMPERATURES.

 Temperature 

extremes can shorten the life of the electronic parts and distort or melt plastic parts. 

3. 

HANDLE THE METER GENTLY AND CAREFULLY.

 Dropping it can damage the 

electronic parts or the case. 

4. 

KEEP THE METER CLEAN.

 Wipe the case occasionally with a damp cloth. DO NOT 

use chemicals, cleaning solvents, or detergents. 

5. 

USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. 

Remove 

old or weak batteries so they do not leak and damage the unit. 

6. 

IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME

, the batteries 

should be removed to prevent damage to the unit. 

BATTERY INSTALLATION 

WARNING

: To avoid electric shock, disconnect the test leads from any source of voltage 

before removing the battery cover. 

1. Turn power off and disconnect the test leads from the meter. 
2. Open the rear battery cover by removing two screws (B) using a Phillips head 

screwdriver. 

3. Insert the battery into battery holder, observing the correct polarity. 
4. Put the battery cover back in place. Secure with the screws. 

WARNING: 

To avoid electric shock, do not operate the meter until the battery cover is in 

place and fastened securely. 

NOTE:

 If your meter does not work properly, check the fuses and batteries to make sure that 

they are still good and that they are properly inserted.  

 

Byram 

Labs

Содержание EX570

Страница 1: ...User s Guide True RMS Multimeter with IR Thermometer Extech EX570 B y r a m L a b s...

Страница 2: ...minals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when...

Страница 3: ...e difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the equipment is used in...

Страница 4: ...UTION when working with high voltages 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 4 NEVER connect the meter leads across a voltage source while the fu...

Страница 5: ...t stand and battery compartment are on rear of unit Symbols and Enunciators Continuity Diode test Low Battery MEM Memory n nano 10 9 capacitance micro 10 6 amps cap m milli 10 3 volts amps A Amps k ki...

Страница 6: ...lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 4 Touch the black test probe tip to the negative side of the circuit Touch the red test probe...

Страница 7: ...circuit under test then open up the circuit at the point where you wish to measure current 7 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the pos...

Страница 8: ...ck 5 If the resistance is less than approximately 35 the audible signal will sound If the circuit is open the display will indicate OL DIODE TEST 1 Rotate the function switch to the green position 2 I...

Страница 9: ...sers do not normally present a hazard but may present some potential for hazard if viewed directly for extended periods of time IR Spot to Distance Diagram The 30 1 spot to distance ratio determines t...

Страница 10: ...to 482 F CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries...

Страница 11: ...utoRanging This automatically selects the best range for the measurements being made and is generally the best mode for most measurements For measurement situations requiring that a range be manually...

Страница 12: ...current The meter can capture negative or positive peaks as fast as 1 millisecond in duration Press the PEAK button PMAX will appear in the display The meter will update the display each time a highe...

Страница 13: ...e chemicals cleaning solvents or detergents 5 USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STO...

Страница 14: ...ix A screws securing the rear cover 4 Gently remove the old fuse and install the new fuse into the holder 5 Always use a fuse of the proper size and value 0 5A 1000V fast blow for the 600 mA range SIB...

Страница 15: ...fied from 5 of range to 100 of range DC Current 400 A 0 01 A 0 7 reading 3 digits 4000 A 0 1 A 40 mA 0 001 mA 400 mA 0 01 mA 1 0 reading 3 digits 10 A 0 00 A 1 5 reading 3 digits 20 A 30 sec max with...

Страница 16: ...Frequency 40 Hz 0 001 Hz 0 1 reading 1 digits 400 Hz 0 01 Hz 4 kHz 0 0001 kHz 40 kHz 0 001 kHz 400 kHz 0 01 kHz 4 MHz 0 0001 MHz 40 MHz 0 001 MHz Duty Cycle 0 1 to 99 90 0 01 1 0 reading 2 digits Pul...

Страница 17: ...ndication for positive Minus sign for negative Measurement Rate 2 times per second nominal Low Battery Indication is displayed if battery voltage drops below operating voltage Battery One 9 volt NEDA...

Страница 18: ...ation improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for a...

Отзывы: