DT200-EU-EN-V2.0 4/12
4
Operating Instructions
Measurement Considerations
1. For best results, choose a target that is flat, hard and smooth
2. Use a section of cardboard or similar material if the target size needs to be increased
3. Replace the battery if the battery icon appears on the display
4. The meter will not measure through glass, liquid, or Styrofoam
5. Inaccurate measurements may result from any of the following:
Low
battery
Measured distance exceeding specified range
Irregular shaped objects near the target
Preparation for Measurements
1. Press the MEAS button
to switch the meter ON. The unit automatically switches OFF after
three (3) minutes of inactivity.
2. Press and hold the UNIT button
to change the unit of measure (ft = feet, in = inches, m =
meters, and ‘ “ (feet and inches).
3. Use the reference button
to select the Top or Bottom distance reference.
In the Top mode (2), the displayed reading will represent the distance from the top of the
meter to the target.
In the Bottom mode (1), the displayed reading will represent the distance from the bottom of
the meter to the target.
Single Distance Measurement
1. Momentarily press the MEAS button to switch the meter ON; Dashes (- - -) will appear on the
display and the Laser pointer will switch ON.
2. Aim the meter and momentarily press the MEAS button again to take and display a reading.
3. The reading will remain on the display for 60 seconds.
1
2