background image

DCP42

en

GB_V1.5

   

12/14

 

4

1.

 

Introduction

 

and

 

Features

 

Thank

 

you

 

for

 

selecting

 

the

 

Extech

 

DCP42

 

Switching

 

Mode

 

Power

 

Supply.

  

This

 

newly

 

re

designed

 

laboratory

 

grade

 

power

 

supply

 

differs

 

from

 

a

 

conventional

 

power

 

supply

 

in

 

that

 

it

 

can

 

calculate

 

and

 

change

 

the

 

voltage

 

and

 

current

 

limit

 

points

 

according

 

to

 

the

 

available

 

maximum

 

power.

 

Therefore

 

the

 

maximum

 

limits

 

of

 

the

 

voltage

 

and

 

current

 

are

 

changeable

 

according

 

to

 

the

 

rated

 

power.

 

A

 

conventional

 

power

 

supply

 

has

 

only

 

a

 

set

 

maximum

 

voltage

 

and

 

current

 

such

 

that

 

all

 

of

 

the

 

operating

 

V

 

&

 

A

 

must

 

fall

 

within

 

these

 

limits.

 

The

 

DCP42

 

offers

 

cost

 

saving

 

and

 

space

 

saving

 

advantages

 

as

 

one

 

constant

power

 

power

 

supply

 

can

 

do

 

the

 

work

 

of

 

several

 

conventional

 

power

 

supplies.

 

 

The

 

DCP42

 

is

 

highly

 

efficient,

 

incorporates

 

upgraded

 

SMPS

 

circuitry

 

with

 

small

 

form

 

factor,

 

benefits

 

from

 

an

 

automatic

 

cross

over

 

for

 

CC

 

and

 

CV,

 

has

 

three

 

(3)

 

Voltage/Current

 

presets,

 

and

 

can

 

be

 

remote

 

controlled.

 

The

 

DCP42

 

is

 

perfect

 

for

 

solving

 

a

 

variety

 

of

 

loading

 

conditions

 

and

 

applications.

 

Features

 

include

 

the

 

following:

 

 

 

Dual

 

action

 

(Course/Fine)

 

tuning

 

provides

 

smooth,

 

accurate,

 

and

 

quick

 

setting

 

of

 

Voltage/Current

 

 

Setting,

 

changing,

 

and

 

verifying

 

the

 

current

 

limit

 

level

 

is

 

convenient

 

and

 

can

 

be

 

performed

 

without

 

output

 

pole

 

spiking

 

 

The

 

Remote

 

Control

 

feature

 

permits

 

output

 

ON/OFF

 

and

 

Voltage/Current

 

adjustments

 

without

 

the

 

need

 

to

 

touch

 

the

 

front

 

panel

 

of

 

the

 

power

 

supply

 

 

The

 

USB

 

port

 

offers

 

PC

 

connectivity

 

for

 

programming

 

and

 

running

 

ramp/soak

 

cycles

 

with

 

20

 

programmable

 

sets

 

of

 

Voltage/Current

 

and

 

varying

 

test

 

durations

 

(up

 

to

 

999

 

cycles)

 

 

The

 

DC

 

ramp

 

and

 

waveform

 

generator

 

can

 

either

 

be

 

panel

 

set

 

or

 

set

 

by

 

the

 

supplied

 

software

 

which

 

previews

 

the

 

final

 

waveform.

 

 

Applications

 

and

 

industries

 

where

 

the

 

DCP42

 

can

 

be

 

employed

 

include

 

laboratory,

 

telecommunications,

 

production

 

testing,

 

field

 

testing,

 

DC

 

network

 

powering,

 

and

 

more

 

 

Three

 

(3)

 

user

 

programmable

 

Voltage/Current

 

settings

 

offer

 

quick

 

recall

 

of

 

frequently

 

used

 

test

 

settings.

 

 

This

 

device

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

our

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

of

 

this

 

User

 

Guide,

 

Product

 

Updates,

 

and

 

Customer

 

Support.

 

 
 

Содержание DPC42

Страница 1: ...USER GUIDE Model DCP42 160W Laboratory Grade Constant Power Switching Mode Power Supply...

Страница 2: ...Activating the Remote Control Mode 8 4 3 3 Deactivating the Remote Control Mode 8 4 3 4 Factory Default Reset 8 5 OPERATION 9 5 1 Powering the Supply 9 5 2 Switching the Power Supply ON and Self Test...

Страница 3: ...sing 12 6 4 1 Connection 12 6 4 2 Disconnection 12 6 5 Remote Control Operation 13 6 5 1 REMOTE CONTROL METHOD 1 Using two external DC voltage sources 13 6 5 2 REMOTE CONTROL METHOD 2 Using two 0 to 5...

Страница 4: ...plications Features include the following Dual action Course Fine tuning provides smooth accurate and quick setting of Voltage Current Setting changing and verifying the current limit level is conveni...

Страница 5: ...nd clear up the cause first Replace the AC fuse with the same type and rating as the original fuse The maximum output voltage of the DCP42 exceeds 60VDC avoid touching the metal contact parts at the o...

Страница 6: ...et Keyd 1 2 3 Menu Key Shift Key Lock Unlock Key A W meter Key Output ON OFF V t Key 7 Output Safety Jacks Rated 10A 8 USB Remote Control port For access to computer to run cyclical operation with pro...

Страница 7: ...red down 4 The user can change these output settings using the voltage and current knobs Recall No Output Voltage Output Current P1 5V Maximum P2 13 8V Maximum P3 40V Maximum 4 3 Set Mode Enter the Se...

Страница 8: ...s located on the front panel will be locked the Lock Unlock button light switches ON 4 3 3 Deactivating the Remote Control Mode a Press the Lock Unlock button to unlock all of the function keys b Repe...

Страница 9: ...d then fine tuning The display will resume its normal brightness after few seconds to confirm an adjustment 5 4 Connecting the Power Supply and running a Test 1 Connect the equipment under test to the...

Страница 10: ...CB Using the AB setting as an example turn the Voltage control knob until A b appears on the voltmeter display and then turn the Current control knob to set to desired transit time t 5 seconds for exa...

Страница 11: ...waveforms Example 1 Pulse waveform with 3sec at 10V and 1sec at 5V Set A Preset 1 5V set B Preset 2 10V Set Func A 1 second by turning the Current control knob Func B 3 seconds using the same procedur...

Страница 12: ...to confirm and to return to normal operation Note The UVL and UCL settings default to the maximum output value 6 4 Remote Sensing Note Observe warnings displayed by the Power Supply an incorrect disco...

Страница 13: ...the power supply by varying the external voltage source Short circuit the main output with 14AWG wire to check the CC setting on the display while varying the external voltage source 6 5 2 REMOTE CONT...

Страница 14: ...all and use the software please refer to the instructions provided on the supplied CD ROM and or the instructions provided in the HELP Utility within the software program Check the software download p...

Страница 15: ...Up Down Left Right keys on PC keyboard for new locations 3 Data that exceed the rated voltage and current will not be accepted 4 Voltages that exceed the UVL Upper Voltage Limit will not be accepted...

Страница 16: ...Set t a b 1 second Set t b a 2 seconds Set Func A 3 seconds Set Func B 3 seconds Example 4 Irregular waveform Set A 5V B 10 V Set t a b 2 second Set t b a 2 seconds Set Func A 2 seconds Set Func B 6 s...

Страница 17: ...ise peak peak Voltage 80mVp p Current Ripple Noise peak peak 50mA Meter Type Accuracy Voltage Meter 4 Digit LED Display 0 1 5 counts Current Meter 4 Digit LED Display 0 1 5 counts Resolution Output Vo...

Страница 18: ...P 3 0KVac I P F G 1 5KVac O P F G 0 5KVac Insulation Resistance I P O P I P F G O P F G 100Mohm 500Vdc EMC CE EN55011 Harmonics Current Emission EN 61000 3 2 Voltage Fluctuations Flicker EN 61000 3 3...

Страница 19: ...heck to see if any ventilation holes are blocked also check that there is sufficient clearance around the power supply Listen carefully for the short wind sound emanating from the cooling fan when the...

Отзывы: