Specifications
Function Range
Resolution
Accuracy
CO
2
0 to 9999ppm
1ppm
±(5%rdg +50ppm)
Temperature
-10 to 60°C
14 to 140°F
0.1° ±0.6°C/0.9°F
Humidity
0.1 to 99.9%
0.1%
±3%(10 to 90%)
±5%(< 10% or > 90%)
Display LCD
Sensor Type
CO
2
: NDIR (non-dispersive infrared) technology
Humidity: Capacitance sensor;
Temperature (air): Thermistor
Response CO
2
: <2min for 90% step change
Temp: <2min for 90% step change
%RH: <10min for 90% step change
Relay 1A
30VDC/0.5A
125VAC
Operating Conditions
-10 to 60°C (14 to 140°F); < 90% RH non-condensing
Storage Conditions
-20 to 60°C (-4 to 140°F); <99% RH non-condensing
Power Supply
5VDC (±10%),
≥
500mA
Dimensions / Weight
117x102x102mm (4.6x4x4”); 204g (7.2 oz.)
Maintenance
CLEANING AND STORAGE
1. The meter should be cleaned with a damp cloth and mild detergent when necessary.
Do not use solvents or abrasives.
2. Store the meter in an area with moderate temperature and humidity.