background image

AN320-en-GB_V1.2   11/14 

6

Operation

 

Air

 

Velocity

 

and

 

Air

 

Volume

 

Measurements

 

1.

 

Switch

 

the

 

meter

 

ON

 

by

 

pressing

 

the

 

POWER

 

 

button

 

momentarily.

  

The

 

meter

 

will

 

countdown

 

from

 

30

 

to

 

0

 

as

 

it

 

performs

 

a

 

self

test.

 

Press

 

the

 

POWER

 

button

 

again

 

to

 

switch

 

the

 

meter

 

OFF.

 

2.

 

Note

 

that

 

the

 

meter

 

will

 

automatically

 

enter

 

the

 

sleep

 

mode

 

after

 

20

 

minutes

 

of

 

inactivity.

 

To

 

disable

 

this

 

feature:

 

with

 

the

 

meter

 

OFF,

 

press

 

and

 

hold

 

the

 

POWER

 

and

 

the

 

U/mode

 

buttons

 

for

 

2

 

seconds.

 

The

 

LCD

 

will

 

display

 

'

n

'

 

as

 

it

 

switches

 

ON.

 

Now

 

the

 

sleep

 

mode

 

is

 

disabled

 

and

 

the

 

user

 

must

 

press

 

the

 

POWER

 

button

 

momentarily

 

to

 

switch

 

the

 

meter

 

OFF.

 

3.

 

When

 

the

 

meter

 

is

 

ON,

 

the

 

upper

 

display

 

can

 

indicate

 

air

 

velocity,

 

relative

 

humidity,

 

or

 

CO

2

 

(use

 

the

 

U/mode

 

button

 

to

 

scroll).

 

The

 

lower

 

display

 

digits

 

can

 

indicate

 

air

 

flow,

 

dew

 

point

 

temperature,

 

wet

 

bulb

 

temperature,

 

or

 

air

 

temperature

 

(use

 

the

 

L/mode

 

button

 

to

 

scroll).

 

4.

 

Place

 

the

 

sensor

 

in

 

the

 

air

 

stream.

 

The

 

air

 

must

 

enter

 

the

 

vane

 

from

 

the

 

rear

 

of

 

the

 

meter.

 

The

 

Air

 

Temperature,

 

Relative

 

humidity,

 

and

 

CO

2

 

sensors

 

are

 

located

 

at

 

the

 

center

 

of

 

the

 

vane

 

on

 

the

 

rear

 

of

 

the

 

meter.

 

5.

 

Read

 

the

 

measurement

 

data

 

on

 

the

 

LCD.

 

Air

 

velocity

 

readings

 

are

 

indicated

 

in

 

meters

 

per

 

second

 

(m/s)

 

or

 

feet

 

per

 

minute

 

(fpm).

 

Temperature

 

readings

 

(air,

 

dew

 

point

 

DP,

 

or

 

wet

 

bulb

 

WBT)

 

are

 

indicated

 

in

 

°C/°F.

 

Air

 

flow

 

(volume)

 

is

 

indicated

 

in

 

CFM

 

(cubic

 

feet

 

per

 

minute)

 

or

 

CMM

 

(cubic

 

meters

 

per

 

minute).

 

Use

 

the

 

L/mode

 

button

 

(for

 

lower

 

display)

 

and

 

the

 

U/mode

 

button

 

(for

 

upper

 

display)

 

to

 

scroll

 

through

 

the

 

displayed

 

reading

 

options.

 

6.

 

To

 

change

 

between

 

Imperial

 

and

 

Metric

 

units

 

of

 

measure

 

refer

 

to

 

the

 

SETUP

 

Mode

 

section.

 

7.

 

To

 

measure

 

the

 

Air

 

Volume

 

of

 

a

 

duct,

 

first

 

measure

 

the

 

duct’s

 

area

 

(see

 

the

 

Appendix

 

for

 

area

 

calculations)

 

and

 

then

 

enter

 

the

 

area

 

value

 

in

 

the

 

meter’s

 

SETUP

 

mode

 

in

 

in

2

 

or

 

cm

2

.

 

After

 

the

 

area

 

value

 

has

 

been

 

entered,

 

use

 

the

 

L/mode

 

button

 

to

 

scroll

 

to

 

the

 

air

 

volume

 

display

 

(CMM/CFM)

 

on

 

the

 

lower

 

digits.

 

Place

 

the

 

meter

 

in

 

air

 

stream

 

to

 

measure

 

volume.

 

8.

 

Optional:

 

measure

 

Air

 

Volume

 

with

 

an

 

airflow

 

Cone

 

or

 

Square

 

adaptor

 

by

 

first

 

attaching

 

one

 

of

 

the

 

adaptors

 

to

 

the

 

meter

 

(the

 

optional

 

cone

 

adaptor

 

kit

 

includes

 

a

 

round

 

and

 

a

 

square

 

cone;

 

kit

 

part

 

number

 

AN300

C).

 

The

 

meter

 

will

 

automatically

 

recognize

 

that

 

the

 

adaptor

 

is

 

attached

 

to

 

the

 

meter

 

and

 

a

 

cone

 

icon

 

will

 

appear

 

on

 

the

 

display.

 

Note:

 

regardless

 

of

 

the

 

AREA

 

setting

 

in

 

the

 

SETUP

 

mode,

 

the

 

meter

 

will

 

default

 

to

 

the

 

dimensions

 

of

 

the

 

vane

 

opening.

  

Ensure

 

that

 

the

 

airflow

 

adaptor

 

is

 

well

 

mounted

 

and

 

locked

 

before

 

taking

 

measurements.

 

LCD

 

backlight

 

Press

 

the

 

U/mode

 

button

 

to

 

switch

 

ON

 

the

 

LCD

 

backlight.

 

The

 

backlight

 

will

 

automatically

 

switch

 

OFF

 

after

 

approximately

 

10

 

seconds

 

to

 

conserve

 

battery

 

power.

 

Note

 

that

 

the

 

backlighting

 

switches

 

ON

 

automatically

 

when

 

the

 

meter

 

is

 

switched

 

ON

 

by

 

the

 

user.

 

Содержание AN320

Страница 1: ...USER GUIDE Large Vane CFM CMM Anemometer Psychrometer CO2 Model AN320 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...ONS Improper use of this meter can cause damage to the meter and personal injury Read and understand this user manual before operating the meter Inspect the condition of the probe and the meter for any damage before operating the meter Repair or replace damage before use If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired ...

Страница 3: ... mode AVG and up arrow button 4 L mode and down arrow button 5 ON OFF Power and SET button 6 HOLD MAX MIN and left arrow Enter button 7 Unit of measure symbol for lower display row 8 Unit of measure symbol for upper display row 9 Air Velocity Vane Meter Description rear 10 Air temperature humidity and CO2 sensors 11 Battery compartment ...

Страница 4: ...E and SETUP mode sections for details Press momentarily to toggle between ppm CO2 humidity and air velocity readings Press and hold for 2 seconds to access the Multi Point Average and Timed Average modes the AVG icon switches ON Detailed instructions for these modes are provided later in this guide In the Setup mode press to select a category or to increase a value refer to Setup mode later in thi...

Страница 5: ...u display parameters 3 Optional Cone or Funnel attachment icon 4 Units of measure for duct area programming 5 Vane indicator flashes very briefly on power up 6 Display HOLD icon 7 MAX mode icon 8 MIN mode icon 9 Recording icon 10 Elapsed Timer icon 11 AVG mode icon 12 Battery status icon 13 Unit of measure icons Full list shown Available units of measure icons vary by model ...

Страница 6: ...ted in C F Air flow volume is indicated in CFM cubic feet per minute or CMM cubic meters per minute Use the L mode button for lower display and the U mode button for upper display to scroll through the displayed reading options 6 To change between Imperial and Metric units of measure refer to the SETUP Mode section 7 To measure the Air Volume of a duct first measure the duct s area see the Appendi...

Страница 7: ...egin displaying the lowest minimum readings encountered since this mode was accessed The MIN icon will appear at the top of the LCD display indicating that the readings shown are the lowest measured 2 Press and hold the MAX MIN button again for 2 seconds to display the maximum readings encountered The MAX icon will appear on the LCD 3 Press and hold this button again for 2 seconds to return to the...

Страница 8: ...se either arrow button to switch between metric and imperial units The available units are air velocity m s fpm temperature C F air volume CMM CFM and area size cm inch 3 Press HOLD momentarily to return to the P1 0 display 4 Press either arrow button to move to the P2 0 AREA option and follow the steps below P2 0 Area Size Selection enter square inches or square centimeters 1 In setup mode from t...

Страница 9: ...in air with an unknown CO2 concentration Doing so will result in the meter being calibrated to the standard 400 ppm and could lead to inaccurate results 1 Place the meter in a calibrated environment 2 With the meter OFF press SET HOLD and L mode simultaneously to enter CO2 calibration mode 3 The meter will run a 30 second countdown and CAL will show in the lower display 4 During calibration a CO2 ...

Страница 10: ...to use the meter Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated ...

Страница 11: ... Area Range CMM cubic meters min 0 99999 m3 min 0 1 up to 9999 9 then 1 0 0 to 99999cm 2 CFM cubic ft min 0 99999 ft 3 min 0 1 up to 9999 9 then 1 0 0 to 99999in 2 Temperature Ranges Resolution Accuracy o F o C Air and Wet Bulb 20 to 60 o C 4 to 140 o F Dew Point 5 to 60 o C 23 to 140 o F 0 1 o C o F 0 6 C 20 to 50 C 1 2 C 51 to 60 C 1 1 F 5 to 122 F 2 2 F 123 to 140 F CO2 Range Resolution Accurac...

Страница 12: ...minutes to preserve battery life sleep mode Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 C to 50 C 14 to 122o F Operating Humidity 80 RH Storage Humidity 90 RH Operating Altitude 2000m 7000 ft maximum Battery Power Four 4 AAA 1 5V batteries Battery Life 40 hours Battery consumption 8 3 mA DC approx Weight 725g 1 6 lbs including battery and probe Dimensions Main instrument...

Страница 13: ...ange limit Test the meter using an air velocity that is known to be within the specified range limits Send the unit to Extech for repair if the E03 error message persists Air volume E03 Reading exceeds the meter s display limit Check that the AREA setting is correct in the Setup Mode E04 Air velocity error Return meter to Extech for repair CO2 E01 E33 Voltage too low or CO2 module error Check if t...

Страница 14: ... Table m s ft min knots km h MPH 1 m s 1 196 87 1 944 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Width W Height H Area A Width W x Height H CFM ft 3 min Air Velocity ft min x Area ft 2 CMM m 3 min Air Velocity m sec x Area m 2 x 60 Radius Area A pi x r 2 Where pi 3 14 and r 2 radius x...

Отзывы: