Extech Instruments AN310 Скачать руководство пользователя страница 9

AN310-en-GB_V1.5   11/15 

9

Battery

 

Replacement

 

When

 

      

 

appears

 

on

 

the

 

LCD,

 

the

 

AAA

 

batteries

 

must

 

be

 

replaced.

 

The

 

battery

 

cover

 

is

 

located

 

on

 

the

 

back

 

of

 

the

 

meter.

 

1.

 

Open

 

the

 

rear

 

battery

 

compartment

 

by

 

carefully

 

pulling

 

down

 

on

 

the

 

compartment’s

 

latch.

 

2.

 

The

 

battery

 

compartment

 

cover

 

should

 

be

 

completely

 

removed

 

before

 

proceeding.

 

3.

 

Replace

 

the

 

four

 

(4)

 

1.5V

 

‘AAA’

 

batteries

 

ensuring

 

proper

 

polarity.

 

4.

 

Close

 

the

 

battery

 

compartment

 

before

 

attempting

 

to

 

use

 

the

 

meter.

 

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Other

 

Battery

 

Safety

 

Reminders

 

o

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

o

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

www.ponpe.com

contact:

[email protected]

Содержание AN310

Страница 1: ...USER GUIDE Large Vane CFM CMM Anemometer Psychrometer Model AN310 contact sale ponpe com www ponpe com ...

Страница 2: ...se damage to the meter and personal injury Read and understand this user manual before operating the meter Inspect the condition of the probe and the meter for any damage before operating the meter Repair or replace damage before use If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired This device should not be made availab...

Страница 3: ...arrow button 4 L mode and down arrow button 5 ON OFF Power and SET button 6 HOLD MAX MIN and left arrow Enter button 7 Unit of measure symbol for lower display row 8 Unit of measure symbol for upper display row 9 Air Velocity Vane Meter Description rear 10 Air temperature and humidity sensors 11 Battery compartment contact sale ponpe com www ponpe com ...

Страница 4: ...for configuring the meter Please review the AVERAGE and SETUP mode sections for details Press momentarily to toggle RH and Air Velocity readings Press and hold for 2 seconds to access the Multi Point Average and Timed Average modes the AVG icon switches ON Detailed instructions for these modes are provided later in this guide In the Setup mode press to select a category or to increase a value refe...

Страница 5: ...3 Optional Cone or Funnel attachment icon 4 Units of measure for duct area programming 5 Vane indicator flashes very briefly on power up 6 Display HOLD icon 7 MAX mode icon 8 MIN mode icon 9 Recording icon 10 Elapsed Timer icon 11 AVG mode icon 12 Battery status icon 13 Unit of measure icons Full list shown Available units of measure icons vary by model contact sale ponpe com www ponpe com ...

Страница 6: ... CFM cubic feet per minute or CMM cubic meters per minute Use the L mode button for lower display and the U mode button for upper display to scroll through the displayed reading options 6 To change between Imperial and Metric units of measure refer to the SETUP Mode section 7 To measure the Air Volume of a duct first measure the duct s area see the Appendix for area calculations and then enter the...

Страница 7: ... will appear at the top of the LCD display indicating that the readings shown are the lowest measured 2 Press and hold the MAX MIN button again for 2 seconds to display the maximum readings encountered The MAX icon will appear on the LCD 3 Press and hold this button again for 2 seconds to return to the normal mode of operation the MIN and MAX icons should switch OFF 4 While viewing the MAX or MIN ...

Страница 8: ...ter the P1 0 UNIT menu 2 Use either arrow button to switch between metric and imperial units The available units are air velocity m s fpm temperature C F air volume CMM CFM and area size cm inch 3 Press HOLD momentarily to return to the P1 0 display 4 Press either arrow button to move to the P2 0 AREA option and follow the steps below P2 0 Area Size Selection enter square inches or square centimet...

Страница 9: ...ver dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point fo...

Страница 10: ...Circuit Custom LSI microprocessor Display Dual function 13 mm 0 5 4 digit LCD Sampling rate 1 reading per second approx Air velocity flow sensor Conventional angled vane arms with low friction ball bearing Sensors NTC type precision thermistors Automatic Power off Auto shut off after 20 minutes to preserve battery life sleep mode Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature ...

Страница 11: ... error Check temperature or RH error solutions Air velocity E03 Velocity exceeds the high range limit Test the meter using an air velocity that is known to be within the specified range limits Send the unit to Extech for repair if the E03 error message persists Air volume E03 Reading exceeds the meter s display limit Check that the AREA setting is correct in the Setup Mode E04 Air velocity error R...

Страница 12: ...196 87 1 944 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Copyright 2014 2015 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form www extech com Width W Height H Area A Width W x Height H CFM ft 3 min Air Velocity ft min x Area ft 2 C...