3. SPECIFICATIONS
3.1 General Specifications
Display
Backlit LCD display
Measurement Ranges
0 to 600
o
F (-20 to 320
o
C)
Sample rate
1 sec. approx.
Power off
Automatic shutoff after 5 seconds
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F).
Operating Humidity
Max. 80% RH.
Power Supply
9V battery
Power Current
Approx. 12 mA DC
Weight
200 g / 6.4 oz.
Size
6.7 x 1.7 x 1.6” (170 x 44 x 40 mm)
3.2 Range Specifications
Resolution/Ranges 1
o
C/F
0 to 600
o
F (-20 to 315
o
C)
Accuracy
± 2% rdg or 4
o
F/2
o
C whichever is greater
Accuracy notes
1. Accuracy specified for ambient temperature
2. Accuracy specified for emissivity of 0.95
Emissivity settings
0.95 fixed
Distance Factor
D/S = Approx. 6:1 (D=distance, S=spot)
Measurement Field
and Target Size
Refer to Chart on top of meter or Fig. 2 in Section 6.1
4. FRONT PANEL DESCRIPTION
1
Laser pointer beam
2
IR sensor
3
LCD Display
4
Units select key
5
Backlight select key
6
Measure key
7
Laser key
8