background image

1                                     42520es       Ver. 1.7    8/00

 

 

INSTRUCTION MANUAL 

 

Model 42520

 

IR Thermometer 

 

 

 

 

 Precise non-contact Measurements 

 

 

 Switchable C/F Temperature units 

 

 

 Automatic Data Hold 

 

 

 Laser target pointer 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. INTRODUCTION 

Congratulations on your purchase of Extech’s 42520 IR Thermometer. This professional 

meter, with proper care, will provide years of safe reliable service. 

 

2. SAFETY 

 

 

 

 

Use extreme caution when the laser beam is ON. 

Do not let the beam enter your eye, another 

person’s eye, or the eye of an animal. 

Be careful not to let the beam from a  reflective 

surface strike your eye. 

Do not use the laser near explosive gases or in 

other potentially explosive areas. 

 

 

 

 

 

Содержание 42520

Страница 1: ...purchase of Extech s 42520 IR Thermometer This professional meter with proper care will provide years of safe reliable service 2 SAFETY Use extreme caution when the laser beam is ON Do not let the beam enter your eye another person s eye or the eye of an animal Be careful not to let the beam from a reflective surface strike your eye Do not use the laser near explosive gases or in other potentially...

Страница 2: ... 6 170 x 44 x 40 mm 3 2 Range Specifications Resolution Ranges 1o C F 0 to 600o F 20 to 315o C Accuracy 2 rdg or 4o F 2o C whichever is greater Accuracy notes 1 Accuracy specified for ambient temperature 2 Accuracy specified for emissivity of 0 95 Emissivity settings 0 95 fixed Distance Factor D S Approx 6 1 D distance S spot Measurement Field and Target Size Refer to Chart on top of meter or Fig ...

Страница 3: ...old the ON HOLD key and then press the BACKLITE key Repeat this procedure to turn the backlight OFF 5 6 Laser Pointer To turn the laser pointer ON press the LASER key while pressing and holding the ON HOLD key Repeat the procedure to turn the laser OFF 5 7 Measurement Considerations a Holding the meter by its handle point the IR Sensor toward the object under test b The object under test should be...

Страница 4: ...ll For periodic calibration NIST certification or repair of any Extech product call customer service for details on services available Extech recommends that calibration be performed on an annual basis to insure calibration integrity 9 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limit...

Отзывы: