V4.0 5/07
3
OVERVOLTAGE CATEGORY III
This meter meets the IEC 610-1-95 standard for
OVERVOLTAGE CATEGORY III. Cat III meters are protected
against overvoltage transients in fixed installation at the
distribution level. Examples include switches in the fixed
installation and some equipment for industrial use with
permanent connection to the fixed installation.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be
operated with caution. The rules listed below must be carefully
followed for safe operation.
1.
NEVER
apply voltage or current to the meter that exceeds the
specified maximum:
Input Protection Limits
Function Maximum
Input
VAC 750V
DC/AC
V DC or V AC
1000V DC/AC, 200Vrms on 200mV range
mA DC
200mA 250V fast acting fuse
A DC
20A 250V fast acting fuse(30 seconds max
every 15 minutes)
Ohms, Continuity
250Vrms for 15sec max
2.
USE EXTREME CAUTION
when working with high voltages.
3.
DO NOT
measure voltage if the voltage on the "COM" input
jack exceeds 1000V above earth ground.
4.
NEVER
connect the meter leads across a voltage source
while the function switch is in the current, resistance, or diode
mode. Doing so can damage the meter.
5.
ALWAYS
discharge filter capacitors in power supplies and
disconnect the power when making resistance or diode tests.
6.
ALWAYS
turn off the power and disconnect the test leads
before opening the covers to replace the fuse or battery.
7.
NEVER
operate the meter unless the back cover and the
battery cover is in place and fastened securely.