Model 401036 Version 3.1   9/07 

Meter Description 

1. 2000 Count LCD includes LUX, Fc, low battery, MAX, H (hold), & x10 indicators 

2. ON/OFF key Turns the meter on or off 

3.  Max. Hold key When pressed, the LCD 

displays only the maximum reading 

4. Lux/Fc key Press to toggle the displayed 

unit of measure. The LCD shows the 
unit 

5. Light Sensor (Lens cover not shown) 

Collects light. Note that a tripod mount 
is located on the rear of the sensor  

6. Range key Press repeatedly to select 

desired range: 20, 200, 2,000, 20,000 

7.  Data Hold key Press to freeze the 

displayed measurement 

8. Record/Erase key Press momentarily to 

store one reading; Press and hold for 3 
seconds to activate the continuous 
recording mode. Press again to end 
recording 

9. RS-232 jack Stereo jack for PC to Meter 

connection cable 

10. Zero adjust Cover the sensor with 

supplied lens cap and adjust the zero 
pot for a 0.0 Fc/LUX display 

Note that the battery compartment, tilt stand, and hanging mount are located on the rear of 
the meter 

Spectral Sensitivity Curve 

                                                                                                     = Light Meter 

                                                                                                                   = V (

λ

)

 

Relative 

Sensitivity (%) 

 

 

 

 

 

                                                             Wavelength (nm)  

100 

 

80 

 

60 

 

40 

 

20 

400     450     500     550     600     650     700 

1

8

7

6

5

4

3

2

9

10

Содержание 401036

Страница 1: ...User s Guide Datalogging Light Meter with PC Interface Model 401036 ...

Страница 2: ...pair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Introduction Congratulations on your purchase of the Extech 401036 Datalogging Light Meter This device measures light intensity to 20 000 Foot candles Fc or Lux 16 000 measurement readings can be logged by the meter and later transferred to PC using the...

Страница 3: ...lect desired range 20 200 2 000 20 000 7 Data Hold key Press to freeze the displayed measurement 8 Record Erase key Press momentarily to store one reading Press and hold for 3 seconds to activate the continuous recording mode Press again to end recording 9 RS 232 jack Stereo jack for PC to Meter connection cable 10 Zero adjust Cover the sensor with supplied lens cap and adjust the zero pot for a 0...

Страница 4: ...or will extinguish Range selection Press the RANGE key to select the appropriate measurement range Start with the lowest range 20 and work up to higher ranges as needed If OL overload is displayed press the range key until a valid reading is displayed Datalogger REC ERASE Key The REC ERASE key is used to record and erase data Press the REC ERASE key once to log one reading REC icon flashes once on...

Страница 5: ...et the rate in the supplied software program as described in the PC SAMPLING paragraph on page 6 2 Datalogger Sampling Rate This is the meter s internal sampling rate used when the meter is logging readings remotely in continuous recording mode disconnected from the PC The default rate is 1 second Change the rate in software by following the steps on page 6 for SAMPLING TIME with the meter connect...

Страница 6: ...ee 3 Phillips screws on the rear of the meter 2 Open the meter housing and replace the battery 3 Close the meter housing and secure the rear screws Calibration and Repair Services Extech offers repair and calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Service Department for information on calibration services available for ...

Отзывы: