background image

380820-en-GB_V1.5   3/15 

12

Specifications 

Front Panel Specifications (AC sine wave output, bandwidth 1kHz) 

Function Range Resolution Accuracy 

Comment 

Voltage 

85V to 250V 

0.1V 

±1% 

THD < 2% 

Frequency 

45Hz to 65Hz 

0.01Hz 

± 0.1 Hz 

Power 

10mW to 100W 

0.1mW 

± 1 % ± 0.05W 

Current 

5mA to 0.6A 

0.1mA/ 1mA 

± 1 % ± 0.5mA 

See notes: 1, 2 

0.6A to 1.5A 

± 1 % ± 5mA 

Power Factor 

PF (0 ~ 1) 

0.001PF 

± 0.04 

NOTE 1: 

The maximum output power is approximately 100VA for duration of 2 minutes; therefore the output current 

may be varied according to the voltage value. For example, after setting the voltage to 

150V, the maximum output 

current will be 0.75A. 

NOTE 2:

 The output duration can be longer than 2 minutes if the output is less than 100VA. If the output is less than 

25VA then the output can run continuously.

 

 

Rear Panel Specifications

 

(Input power is looped through to the REAR output)

 

(Max. 2000VA/220V, 1100VA/110V, AC Measurement)

 

Function Range  Resolution 

Accuracy 

Power 

100mW to 2000W 

0.1mW/1mW/ 

0.01W/0.1W/1W 

± 1 % ± 0.5W 

Voltage 

85V to 250V 

0.1V 

± 1 % 

Current 

5mA to 0.6A 

0.1mA/ 

1mA/ 

0.01A 

± 1 % ± 5mA 

0.6A to 1.5A 

± 1 % ± 50mA 

1.5A to 10A 

± 1 % ± 0.1A 

Power Factor 

PF (0~1) 

0.001PF 

± 0.04 

Frequency 

45Hz to 65Hz 

0.01Hz 

± 0.1Hz 

THD 

THD (0.0 - 20.0%) 

0.1% 

± 2% 

THD (20.0 – 100%) 

±3% of reading ±5% 

THD (100 – 999.9%) 

±10% of reading ±10% 

Harmonics 

Hn (1 – 10

th

0.1mA/ 0.001A/ 

0.01A 

mA: ±1.4% of reading ±5mA 

A: ±1.4% of reading ±0.3A 

Hn (11 – 20

th

mA: ±4% of reading ±5mA 

A: ±4% of reading ±0.3A 

Hn (21 – 50

th

Amp range 

mA: ±10% of reading ±5mA 

A: ±10% of reading ±0.3A 

Hn (21 –50

th

mA range 

mA: ±20% of reading ±5mA 

A: ±20% of reading ±0.3A 

 

Содержание 380820

Страница 1: ...User s Guide Universal AC Power Source AC Power Analyzer Model 380820...

Страница 2: ...ly to a mains outlet with an earth ground connection Do not place the equipment on damp or wet surfaces Do not subject the equipment to direct sunlight or extreme temperatures Do not subject the equip...

Страница 3: ...r loss of life and prevent damage to this product Earth Ground Terminal This unit has been tested and meets or exceeds the following standards 1 EN61326 1 2006 CISPR11 IEC EN 61000 3 2 2006 IEC EN 610...

Страница 4: ...ft 4 LCD Liquid Crystal Display 5 RECALL Recalls stored voltage and frequency values there are 99 sets of preset values in the memory The currently selected voltage and frequency values will clear whe...

Страница 5: ...s to save the currently programmed voltage and frequency to one of the memory locations 1 to 99 and press V ENTER to confirm The currently selected voltage and frequency will be stored in the selected...

Страница 6: ...ic Test Setup Diagram Connect the Unit Under Test to the 380820 Front and Rear Output Select When the unit is switched ON use the OUTPUT button to select the display for the Front or Rear output data...

Страница 7: ...t is 0V however the output terminals are still physically connected to the internal circuit Frequency Output Front Output Rear Measurement 1 Type the desired frequency value and then press the Hz butt...

Страница 8: ...t offers 99 memory locations To Store 1 Ensure that the desired voltage and frequency values are correctly set 2 Press the STORE button verify STORE _ appears on display 3 Assign a memory location num...

Страница 9: ...press the button 2 When the unit is in OPER Output Mode changing the OCP value or the Voltage value will switch the mode from OPER to STBY standby Therefore pay careful attention to this operation 3 I...

Страница 10: ...the FUNC button is pressed the LCD will display Voltage THD and harmonics n 1 50 Use the buttons to select the harmonics to be displayed 3 When the FUNC button is pressed again the LCD will display t...

Страница 11: ...the output will be placed in STANDBY mode and the LCD will display OVERHEATED A displayed timer indicates the remaining cooling time that must elapse before the unit can be switched ON again When the...

Страница 12: ...2 minutes if the output is less than 100VA If the output is less than 25VA then the output can run continuously Rear Panel Specifications Input power is looped through to the REAR output Max 2000VA 2...

Страница 13: ...ity 85 RH Operation Temperature 4C to 60C 40 F to 140 F Accessories Power cord Software CD ROM RS232C to USB cable Dimensions 260mm x 151mm x 305 mm 10 2 x 5 9 x 12 0 Weight 9 9 kg s 21 8 lb Copyright...

Отзывы: