 Model 380363 Version 2.0 July 2005 

Insulation Resistance Measurements (Megohmmeter Tests) 

Warning

: Do not perform Insulation Resistance measurements if AC Voltage is present on the 

device under test. 

1.  Connect the red test lead to the V

 input terminal; black lead to the COM terminal. 

2.  Set the function switch to the desired M

Ω 

test voltage position. 

3.  Connect the tips of the test leads to the equipment under test. If there is a voltage 

present, it will be displayed. A repetitive beep and the flashing high voltage symbol  

will be displayed if the voltage is over 30V. 

4.  The display will show “----“ until the TEST button is pushed. Press and hold the TEST 

button. The upper right display shows the test voltage applied. The main display 
shows the resistance. If the display reads OL, the measurement is beyond the range 
of the instrument. 

5.  Keep the test leads connected to the equipment under test and release the TEST 

button. The circuit will discharge through the meter. Keep the test leads connected 
until the circuit is completely discharged and the upper right display shows 0 volts. 

Test Lock Function 

For hands-free operation, use the TEST LOCK feature. 

1.  With the test leads connected to the equipment under test, press the LOCK key to 

enter the LOCK mode. The LOCK icon “   “ will appear on the display. 

2.  Press the TEST key to start the test. A beeper will sound every 2 seconds to indicate 

that the meter is in Lock mode. 

3.  Press LOCK or TEST to disable the Lock function and end the test. 

Notes on IR (Megohmeter) testing: 

1. 

The maximum measurement range for the 380363 is 10G

. Frequently, insulation 

resistance will exceed this value and the meter will show the overload display 
symbol OL, indicating that the insulation under test is good. 

2. 

If the device being tested is highly capacitive, the display will indicate an increasing 
resistance value over time. Allow the reading to stabilize before ending a test. 

Manual Data Store and Read Mode 

To Clear Memory 

1. 

Turn the meter off. 

2. 

Press and hold down the MEM key, and turn the meter on. 

3. 

The display will show “MEM0” in the upper left hand corner - indicating that the 
memory has been erased. 

Entering data into memory 

1. 

Press the MEM key to enter the displayed data into memory (a beep will sound). 

2. 

The display will show “MEM” and the memory address number in the upper left 
hand corner. Total memory size is 9 sets. 

3. 

When memory is full, the meter will sound two quick beeps. 

Reading memory data 

1. 

Press the READ key to enter Read Mode. The display will show the “READ” icon 
and the memory address number in the upper left hand corner. 

2. Use 

the 

 and  

 arrow keys to scroll through the stored readings. 

3. 

Press the READ key again to exit this mode. 

Содержание 380363

Страница 1: ...tions on your purchase of Extech s Insulation Tester Megohmmeter The Model 380363 provides three test ranges plus continuity and AC DC voltage measurement Manual datalogging stores up to 9 data sets This professional meter with proper care will provide years of reliable service ...

Страница 2: ...this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Specifications General specifications Display 3 3 4 digit 4000 count LCD Sampling rate 1 reading per second Test ranges Resistance 4MΩ 40MΩ 400MΩ 4000MΩ 10GΩ Test Voltages 250V 500V 1000V AC DC Voltage range 999V Resistance range 9999Ω Lo Resistance range 40Ω Over range indicator OL displayed when measur...

Страница 3: ...nt 1mA Circuit Protection Test inhibited if input 30V AC or DC AC VOLTAGE 40Hz 500Hz Range Res Accuracy Input impedance Overload Protection 999VAC 1V 2 2d 9MΩ 1000Vrms DC VOLTAGE Range Res Accuracy Input impedance Overload Protection 999VDC 1V 1 2d 9MΩ 1000Vrms RESISTANCE CONTINUITY Range Res Accuracy Max open circuit Volt Overload Protect Resistance 999 9Ω 0 1Ω 1 3d 3V 1000Vrms Continuity 100Ω 80...

Страница 4: ...gether 3 Resistance should read less than 0 5Ω and the audio tone should sound 4 With the leads not touching the display should read OL indicating over range 5 Readings displayed other than the readings described above are evidence of a problem and the test leads must be replaced before using the meter Failure to do so could result in damage to equipment and electrical shock If replacing the test ...

Страница 5: ...r the LOCK mode The LOCK icon will appear on the display 2 Press the TEST key to start the test A beeper will sound every 2 seconds to indicate that the meter is in Lock mode 3 Press LOCK or TEST to disable the Lock function and end the test Notes on IR Megohmeter testing 1 The maximum measurement range for the 380363 is 10GΩ Frequently insulation resistance will exceed this value and the meter wi...

Страница 6: ...t is less than approx 100Ω 80Ω the audible tone will sound LOΩ Low Resistance Measurement 1 Set the Rotary switch to the LoΩ position 2 Connect the red test lead to the VΩ terminal and the black lead to the COM terminal 3 Touch the test leads together and press the key to zero the display 4 Connect the probes to the ciruit under test If there is a voltage present it will be displayed A repetitive ...

Страница 7: ...ired function Analog Bar Graph The analog bar graph displays resistance on a logarithmic scale and voltage on a linear scale The value always tracks the main display Maintenance Battery Replacement When the low battery symbol appears BT on the LCD the six 1 5V AA batteries must be replaced 1 Turn the meter off and remove the test leads 2 Remove the four 4 Phillips head screws on the rear of the me...

Страница 8: ...ains switch If the mains switch is opened and the motor also has a motor starter then the starter must be held in the ON position With the mains switch opened the measured resistance will include the resistance of the motor wire and all other components between the motor and the main switch If a weakness is indicated the motor and other components should be checked individually If the motor is dis...

Страница 9: ... also applies to DC Generators Testing Cables 1 Disconnect the cable under test from the line 2 Disconnect the opposite end of the cable to avoid errors as a result of leakage from other equipment 3 Check each conductor to ground and or lead sheath by connecting one meter lead to ground and or lead sheath and the other meter lead to each of the conductors in turn 4 Check insulation resistance betw...

Страница 10: ...he instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges fre...

Отзывы: