 Model 380360 Version 1.7 September 2003 

Safety 

1.  Circuits under test must be de-energized and isolated before connections are made 

(except for voltage measurements). 

2.  Circuit connections must not be touched during a test. Use extreme caution when 

working near bare conductors and bus bars. Accidental contact with conductors could 
result in electrical shock. 

3.  Use caution when working near voltages above 60VDC or 30VACrms. 
4.  After insulation tests, capacitors must be discharged. 
5.  Test leads (including alligator clips) must be in good working order, clean and without 

broken or cracked insulation. 

6.  When servicing, use only specified replacement parts. 

 

International Safety Symbols 

 
 

Caution, refer to this manual before using this meter 
 
 
Dangerous Voltages 
 
 
Meter is protected throughout by double or reinforced insulation 

 

Specifications 

 

General specifications 
 

Display 

0.65” 3-1/2 digit (2000 count) LCD 

Sampling rate 

2.5 readings per second 

Test ranges 

2000M

/1000VDC, 200M

/500VDC, 200M

/250VDC 

AC Voltage range 

600VAC 

Resistance  range 

200

 

Over range indicator 

‘1____’ displayed 

Zero adjust 

Automatic 

Low battery indicator 

‘BT’ symbol displayed when battery voltage is low 

Power source 

Six (6) 1.5 ‘AA’ batteries 

Power consumption 

20 to 95mA (depending upon function) 

Operating conditions 

32 to 104

o

F (0 to 40

o

C); 80% RH 

Dimensions 

6.5 x 3.9 x 2.2” (165 x 100 x 57mm) 

Weight 

1.1 lbs (500g) 

 

 
 

Содержание 380360

Страница 1: ...ongratulations on your purchase of Extech s Insulation Tester Megohmmeter The Model 380360 provides three test ranges plus continuity and an AC voltage test A handy 3 minute test lock feature and a data hold switch are also included This professional meter with proper care will provide years of reliable service ...

Страница 2: ... insulation 6 When servicing use only specified replacement parts International Safety Symbols Caution refer to this manual before using this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Specifications General specifications Display 0 65 3 1 2 digit 2000 count LCD Sampling rate 2 5 readings per second Test ranges 2000MΩ 1000VDC 200MΩ 500VDC 200MΩ 250VDC...

Страница 3: ...ircuit Volt Overload Protect 200Ω 0 1Ω 100Ω 3 3V 500Vrms AC VOLTAGE Range Res Accuracy Input impedance Overload Protect 600VAC 1V 0 8 3d 10MΩ 750Vrms MEGOHMMETER RANGES Range Res Accuracy Terminal voltage 200MΩ 250VDC 250V 10 0 200MΩ 500VDC 0 1MΩ 500V 10 0 0 to 1000MΩ 1000VDC 3 5d 1000 to 2000MΩ 1000VDC 1MΩ 5 5d 1000V 10 0 Range Test Current Load Short circuit Current 200MΩ 250VDC 250KΩ 200MΩ 500V...

Страница 4: ...rotary switch to the 200Ω range 3 Set the HOLD switch to the left off position and the MANU LOCK switch to the MANUAL position 4 Touch the test lead tips together 5 Press the red TEST button 6 Resistance should read less than 1Ω and the audio tone should sound 7 With the leads not touching the display should read 1__ indicating over range 8 Readings displayed other than the readings described abov...

Страница 5: ...to the HI input terminal black lead to the LO terminal 2 Set the rotary switch to the desired voltage test position 250V 500V or 1000V 3 Connect the tips of the test leads to the equipment under test 4 Set the MANU LOCK switch to the LOCK position 5 Press and release the red TEST button A 3 minute continuous test will begin The red TEST button can be pressed at any time to end the test If the TEST...

Страница 6: ...her end of the test leads to the circuit under test 4 Read the voltage value on the LCD Data Hold Function The Data Hold function freezes the displayed reading Move the HOLD switch to the rightmost position to freeze the displayed reading The H will appear on left side of the display when the meter is in the Data Hold mode Move the switch to the left position to exit the Data Hold mode the H indic...

Страница 7: ...nd the other lead to the brush on the commutator 3 If the resistance measurement indicates a weakness raise the brushes off of the commutator and separately test the armature field coils and brush rigging one at a time Leave one lead connected to the grounded motor housing while testing the motor components This also applies to DC Generators Testing Cables 1 Disconnect the cable under test from th...

Страница 8: ...CH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website ...

Отзывы: