67
NO-LOAD PERFORMANCE
z
Disconnect the magneto lead wire coupler.
z
Start the engine and keep it running at 5000r/min.
z
Using a pocket tester, measure the AC voltage between
the white and red tracer lead wire and ground. If the
tester reading is as follows, magneto is in good
condition.
Standard no-load performance: more than 65v(AC)AT
5000R/MIN.
STATOR COILS
Inducing coils
Use procket tester to measure the resistance between the lead
wire and ground. If the resistance checked is not correct,
replace the coil.
Rregulator/rectifier
Disconnect the lead wire couple.
Using the pocket tester
᧤
1KQ RANGE
᧥
, measurethe
resistance between the terminals as shown in the following
table. If the resitance checked is incorrect, replace the
regulator/rectifier.
UNIT: KQ
NOTES
᧶
Including the components such as
transistor,capacitance, regulator diode and so on, so tested
resistance may be different from actual resistance.
Standard
resistance
W/R-GROUND 0.6-1.1Q
W/R-GROUND 0.5-0.8
Q
Содержание GT 50
Страница 1: ...1 Service and Maintenance Manual 50ccm ...
Страница 3: ...3 ...
Страница 20: ...21 ི ཱ ཱི ུ ཱུ ྲྀ ཷ ླྀ ཹ 14 ...
Страница 46: ...49 z install the bearingཱ in the fixed driven face with the special tool z install sliding bearing ིᇭ ...
Страница 56: ...59 CHAPTER 4 FUEL AND LUBRICATION SYSTEM CONTENTS FUEL SWITCH CARBURETOR OIL PUMP ...
Страница 77: ...80 3 Disconnect throttle cableི and oil pump cableཱི 4 Remove rear brake cable adjusting nut ུ ི ཱི ུ ...
Страница 102: ......
Страница 103: ...106 WIRE CABLE AND BRAKE HOSE ROUTING ...
Страница 104: ...107 carburetor ...
Страница 105: ...108 ...
Страница 106: ...109 Ignition coil Starting relay CDI HORN POWER SWITCHH ...
Страница 108: ...111 ཱི ུ ཱུ ྲྀ ཷ ླྀ ཹ ...