Pg.
11
•
To move the dial use a small screwdriver, coin, or other flat tool
and insert it into the arrow shown on the left. Turn the screwdriver
so that the arrow in the BAT Type Dial points to the desired
Switch Setting
shown below.
•
Use your fingernail, pen, or small enough object to change the
switches to the desired priority.
Using the Battery Type Dial:
01
2
3
4 5 6 7
8
9
BATTERY
TYPE
Using the Priority Switch:
- Switch 1:
Move to "ON" to set frequency to
60Hz.
For
50Hz
, set
the switch back down (not usually used in the USA).
- Switch 2:
Move to "ON" to set priority to
DC.
For
AC
priority, set
the switch back down (Recommended).
ON
1 2
SWITCH
PRIORITY
Different kinds of batteries have varying charging algorithms. In order to protect your
power system, our inverter is designed to be suitable for a variety of different types of
batteries. On the top of the inverter, you can choose the battery type to your needs
using the Battery Type Dial and the Battery Type Settings Table below to ensure that
your battery is with in optimal condition.
Battery Type Settings Table:
Battery Type Selections and Priority Switch
FACTORY DEFAULT
Gel USA
AGM 1
AGM 2
Sealed Lead Acid
Lithium Iron-Phosphate (LiFePO4)
Open Lead Acid
Calcium
Desulphation
Not Used
Description
Switch Setting
0
1
2
3
4
5
6
7
8
9
Voltage
Boost
12V
No Charging
14.0
14.1
14.6
14.4
14.4
14.8
15.1
15.5
-
Voltage
12V
Float
No Charging
13.7
13.4
13.7
13.6
13.8
13.3
13.6
4 Hours Then Off
-
Содержание IVOCH2KW
Страница 1: ...For Models IVOCH2KW IVOCH3KW Pure Sine Wave 2000W 3000W Inverter Charger OWNER S MANUAL 110V 12V ...
Страница 22: ...Pg 21 Notes ...