background image

EX-9133C-2-MTCP User Manual 

 

EX-9133C-2-MTCP  •  Manual Version 1.0.1  •  201016 

  www.topsccc.com 

                                                                         Page 

0

 

 

 

Operation Manual   

EX-9133C-2-MTCP

     

 

Modbus TCP to Modbus RTU/ASCII

 

Converter

 

   

 
 

 

 
 

Version 1.0.1    20th Oct. 2016 

Содержание EX-9133C-2-MTCP

Страница 1: ...EX 9133C 2 MTCP User Manual EX 9133C 2 MTCP Manual Version 1 0 1 201016 www topsccc com Page 0 Operation Manual EX 9133C 2 MTCP Modbus TCP to Modbus RTU ASCII Converter Version 1 0 1 20th Oct 2016 ...

Страница 2: ...ts 1 Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 7 Product Specifications 8 2 EX 9133C 2 MTCP Description 10 Product Panel Views 10 Top Side 10 Right Side 10 3 EX 9133C 2 MTCP Installation 12 Power Supply Left Side 12 Ethernet Port 12 Reset 12 LED Indicators 13 Wiring Architecture 14 ...

Страница 3: ...dify IP 18 EXBrowser Modify MAC 20 Web Browser Configuration 21 Controller Setup Status 21 Controller Parameter Setup 24 Controller Updated 29 Factory Default Setting 30 Appendix A FAQ 31 Appendix B Pin Outs and Cable Wiring 32 B 1 DC In Jack 32 B 2 RJ 45 Pin Assignment 32 B 3 RS 232 Pin Assignment 32 B 4 RS 232 Wiring Diagram 33 B 5 RS 422 Pin Assignment 33 B 6 RS 422 Wiring Diagram 33 B 7 RS 485...

Страница 4: ...e is a RS 232 and another is RS 422 485 Auto Detect All serial ports operate in common industrial configuration EX 9133C 2 MTCP converter is a low cost high performance design By carefully selecting high quality with competitive prices components in the world the products made network connectivity possible with affordable cost for virtually all kinds of devices EX 9133C 2 MTCP is a full set conver...

Страница 5: ...Model EX 9133C 2 MTCP provides 1 socket connection for remote management ARM Cortex M4 CPU Series Virtual COM driver and software that works with COM port can be set up to work over a TCP IP network in no time This excellent feature preserves your software investment and let you enjoy the benefit of networking your serial devices instantly ARM Cortex M4 CPU series converter supports manual configu...

Страница 6: ...ial control systems networking by converting data stream between network TCP IP and popular serial port signals Instead of processing TCP IP packets directly devices need only deal with those interface signals which greatly simplifies the complexity of TCP IP network in linkage The ARM Cortex M4 processor provides outstanding computational performance and exceptional system response to interrupt w...

Страница 7: ...divide to deliver an outstanding efficiency of 1 25 DMIPS MHz The ARM Cortex M4 processor also implements the new Thumb 2 instruction set architecture which combined with features such as unaligned data storage and atomic bit manipulation delivers 32 bit performance at a cost equivalent to modern 8 and 16 bit devices ...

Страница 8: ...ration Support DHCP client mode simplifying network address configuration and management Dual LAN Speed Support 10 100 Mbps Ethernet auto detected Server Client Dual Modes EX 9133C 2 MTCP converter device can be configured as network server or network client In the client mode it can be installed in network which is protected by NAT router or firewall without a real IP address Web based Setup Para...

Страница 9: ...dbus TCP Client Server Setup HTTP Browser Setup IE Netscape Security Login Password Protection Built in 1 5KV Magnetic Isolation About to json Remote IP Report ID Support Serial Port No of Ports RS 232 1 Port and RS 422 485 Auto Detect 1 Port Port Type DB9 male 1 and Terminal Block 7pin 1 Speed 300 bps 115 2K bps Parity None Odd Even Mark Space Data Bit 5 6 7 8 Stop Bit 1 2 Port 1 One RS 232 Signa...

Страница 10: ...nction Virtual Support Windows 2000 2003 XP Vista 7 Firmware On line Updated Via Ethernet Power DC 9 24V 500mA Terminal Block Optional DC Jack Default LED Lamp Port 1 Red Port 2 Green DI DO Red SYS Green It is a device status indicator Environment Operating Temperature 0 70 Storage Temperature 10 80 Dimensions 115 90 27 mm W D H WEIGHT 140 gm RoHS Compliant with RoHS Regulatory Approvals FCC CE WA...

Страница 11: ...p Side Right Side Serial I O Port of RS 232 and RS 422 485 Connect the serial data cable between the converter device and the serial devices Follow the parameter setup procedures to configure the converter see the following chapters DC In Power Outlet Ethernet LAN Port Serial I O Port RS 232 Serial I O Port RS 422 485 LED Indicators Reset Button RS 232 RS 422 485 ...

Страница 12: ...Ethernet LAN Port The connector for network is the usual RJ45 Simply connect it to your network switch or Hub When the connection is made the LAN LED indicator will light up When data traffic occurs on the network red DATA LED indicator will blink during data transferring and receiving Reset Button If by any chance you forget the setup password or have incorrect settings making EX 9133C 2 MTCP con...

Страница 13: ...sending to the network the LED will blink PORT 2 Green Port2 data transmitting indicator When data are sending to the network the LED will blink DI DO Red Data input output indicator When data are input output by the network the LED will blink SYS Green It is a device statues indicator When EX 9133C 2 MTCP is operated in normal statues the LED will blink once per second ...

Страница 14: ...EX 9133C 2 MTCP User Manual EX 9133C 2 MTCP Manual Version 1 0 1 201016 www topsccc com Page 13 Wiring Architecture RS 232 Wiring Architecture ...

Страница 15: ...chitecture When you finish the steps mentioned above and the LED indicators are as shown in above diagram the converter is installed correctly You can use the Setup Tool EXBrowser exe to setup the IP Address To proceed the advanced parameter setup please use a web browser IE or Netscape to continue the detailed settings ...

Страница 16: ...ls about network settings please see the Network Settings section in Chapter 4 Web Browser Configuration The following topics are covered in this chapter Device Management Utility of EXBrowser EXBrowser View EXBrowser Modify IP EXBrowser Modify MAC Device Management Utility of EXBrowser On PC we provide a Device Management Utility named EXBrowser exe which is an executable program in Windows 32 bi...

Страница 17: ...n one converter on the network please shut down or disconnect other converters Otherwise the EXBrowser exe can not detect the converter Due to the nature of broadcast UDP packets EXBrowser has following characteristics Broadcast packets are not limited by subnet Even if the IP address of the converters and the computer running EXBrowser that do not belong to the same subnet it still works fine Bro...

Страница 18: ...status of existing devices You may select the item View to refresh the status of existing devices on LAN Another is to click the icon as red color remark as below EXBrowser will send another query to get updated information see Figure 4 2 Note Always run the Refresh after any data change Figure 4 2 File Exit Alt F4 Exit from the program see Figure 4 3 Figure 4 3 ...

Страница 19: ...ces list in the EXBrowser table and then the function bar will be enable To press second icon of Modify IP on function bar and a dialog frame table will be shown see Figure 4 4 Figure 4 4 Assign an IP Address with the same Subnet Mask of your computer avoiding any IP conflict with other network devices When you press Confirm button the IP address will be refreshed in 2 3 seconds ...

Страница 20: ...1 201016 www topsccc com Page 19 Figure 4 5 After click Confirm button and then Input Password request will be pop up on screen see Figure 4 5 Please simply press Confirm button and the new device s IP will be changed and save in table if you changed it Figure 4 6 ...

Страница 21: ...ble and then the function bar will be enabled To press Third icon of Modify MAC on function bar and a dialog frame table will be shown see Figure 4 7 Figure 4 7 Input Password Dialog Frame After click Confirm button and then Input Password request will be pop up on screen see Figure 4 8 Please simply press Confirm button and the new device s MAC will be changed and save in table if you changed it ...

Страница 22: ...rter device is as easy as surfing on WWW no special software will be required Popular Browsers such as IE or Netscape can easily do the setup process In the browser URL field set the IP address of device directly to enter the Login Setting page please follow the steps below Open your browser This chapter will use IE as an example In the browser URL field type the IP address of the converter direct...

Страница 23: ... elapsed since start of this device in Day Hour Minute Second format This information can be useful in identifying the reliability of system Firmware version Converter firmware is identified by date code This information will be required looking for technical support Serial number It is a product serial number code in the converter device and has been provided by factory ...

Страница 24: ...e password you can Reset this converter First turn on the power Second use any point tip to push this button and hold it about 3 seconds All the parameters will be reset to the factory default But do not over 5 seconds it will enter update mode Converter device uses the same password protection mechanism commonly used in Windows NT or UNIX If there are more than 3 consecutive failures in password ...

Страница 25: ...ng Page The Parameter Setting Page Type the correct password in the Password field and click the Confirm button in the Login Setting page then the Parameter Setting page will be shown see Figure 4 10 Note If you forget the password or can t login successfully please contact the manufacturer directly Figure 4 10 ...

Страница 26: ...ork this field will be assigned by DHCP server automatically Gateway address Gateway or Router IP address Gateway is a device which connects local network to external network If you need to communicate with other networks or your device owns a real IP address on the internet please inquire of them that information and type it correctly If there s no gateway on the network just leave it as 0 0 0 0 ...

Страница 27: ...s a 16 bit numbers ranging from 1 to 65535 Because the numbers below 1000 are used for specific purposes e g 80 is for HTTP protocol we suggest you use the numbers larger than 1000 Generally the port number 4660 is used for the serial communication However you should specify different port number for each serial port Socket type Modbus TCP Server Modbus TCP protocol passive open to be connected fr...

Страница 28: ...sTCP to Modbus RTU Modbus ASCII or Modbus RTU Modbus ASCII to ModbusTCP Serial I O Port 2 RS 422 485 This converter device model is provided second serial port as RS 422 485 Auto Detect interfaces for connecting the extension serial device Local Port Socket Mode Remote IP Port This converter device provides one socket connection port Port number A socket port is assigned for the serial port It s a...

Страница 29: ...arity Data bits Stop bit Parity None Even Odd Space Mark Data Bits 5 6 7 8 Stop Bit 1 or 2 Force off line time Close the Socket It is for setting the off line time period of device will be taken when there is no date input The parameter can be from 1 to 255 and the time unit is Minute Packet Collect Time It is for setting a packet collecting period of the device serial port s Tx and Rx The paramet...

Страница 30: ...d then reboot see Figure 4 11 It takes about 5 seconds to complete the whole process and a new login page will be presented see Figure 4 9 Figure 4 11 You can re login and check if all parameters have been correctly saved If everything is ok you can close the browser now Note If the domain of the converter is different from that of the computer running the browser the login page won t appear unles...

Страница 31: ...up password or have incorrect settings making the converter inoperable there are two ways to reset the setting and the following procedures can be used to reset all settings to factory default A 1 Please turn on the power and then use any point tip to push Reset button for 5 seconds The password will be reset to the factory default as empty ...

Страница 32: ...ect the converter on the network A Please check if the power is properly plugged to the converter if the network cable is properly connected between the converter and the Hub Please refer to the Hardware Installation steps in Chapter 3 Q Why can t I use IE to setup the converter A Please check if the network domain of your PC is the same as that of the converter ...

Страница 33: ...om Page 32 A Ap pp pe en nd di ix x B B Pin outs and Cable Wiring DC In Jack RJ 45 Pin Assignment RS 232 Pin Assignment The pin assignment scheme for a 9 pin male connector on a DTE is given below PIN 1 N A PIN 2 RXD PIN 3 TXD PIN 4 DTR PIN 5 GND PIN 6 DSR PIN 7 RTS PIN 8 CTS PIN 9 N A ...

Страница 34: ... EX 9133C 2 MTCP 2 RX 3 TX 3 TX 2 RX 5 GND 5 GND 7 RTS 8 CTS 8 CTS 7 RTS RS 422 Pin Assignment The pin assignment scheme for a 4 pin RS 422 is given below PIN 1 T PIN 2 T PIN 3 R PIN 4 R RS 422 Wiring Diagram Serial Device EX 9133C 2 PoE R 2 T R 1 T T 4 R T 3 R RS 485 Wiring Diagram Serial Device EX 9133C 2 PoE D 1 D D 2 D 1 2 3 4 ...

Отзывы: