20
13. ELECTRIC PANEL
Connect the power supply to the electrical panel as explained
in the chapter on electrical panel installation.
START-UP
1) Open the door and turn the main switch from 0 (zero) to 1
(one).
2) The signal lamp must light up with GREEN light to indicate
correct operation of all systems.
3) Turn the potentiometer to adjust the intake speed according to
the operating requirements.
STOP
1) Open the door and turn the main switch from 1 (one) to 0
(zero).
2) The signal lamp turns off.
14. PROBLEMS ON THE MACHINE
TYPE OF FAILURE
CAUSE
INTERVENTION
No supply voltage
Check that the socket is powered by the required
supply voltage
General switch in position 0
(zero)
Turn the switch to the ON position (1)
Filter access doors of the open
machine
Close the filter access door with the special
closures
MACHINE DOES NOT
START
Machine door microswitch not
pressed or broken
Check that the microswitch press pin is intact and
press the limit switch correctly
Verify that the limit switch is working
Verify that the cables are connected and intact
Tripped thermal magnetic
circuit breaker due to a short
circuit
Remove the short circuit (contact assistance).
Machine door microswitch not
pressed or broken
Check that the microswitch press pin is intact and
press the limit switch correctly
Verify that the limit switch is working
Verify that the cables are connected and intact
SIGNAL LAMP OFF
Blown fuse
Replace the fuse with another of the same value
and type. If it blows again remove the electrostatic
filters and the ionisation and ozonisation sections
from the unit to check if one of these components