6. ELECTRIC PANEL INSTALLATION
The electrical panel is supplied with brackets for wall mounting and it is connected and wired up to the first
junction box by a flexible sheath with a standard length of 3m.
Mount the special brackets on the panel and fix it to the wall with suitable plugs.
Deliver the supply voltage by the supplied socket, observing the neutral and earth connections.
The phase sequence in three-phase systems does not matter since the fan is electronic and can never turn
in the opposite direction.
6.1
ELECTRICAL CONNECTION
To power the machine, it is necessary to provide the power supply using the special plug supplied with the
electrical panel.
The connection must be set up by an electrician. The earthing system shall be provided by the user.
The electrical supply network for the panel must meet the following conditions:
For machines with single-phase power supply, recognisable by a 3-pin BLUE plug
Voltage
: 230V +/- 10% Volt
Frequency
: 50/60 Hz
Minimum available power
: 1.5 kW
For machines with three-phase + neutral power supply, recognisable by a 5-pole RED plug
Voltage
: 400V +/- 10% Volt between neutral line
Frequency
: 50/60 Hz
Minimum available power
: 3.5 kW
6.2
DISASSEMBLY
Proceed as follows:
- disconnect the electrical panel from the electrical supply network
- disconnect the pipes or accessories set up for fumes intake
- disconnect the sections of the machine
- remove the machine