background image

16

MANUGENETOP6xx 

Operating Instructions

VER 1.03

5 Connections

1. Serial Port

2. 2x Ethernet Port

3. USB Port

4. Power Supply 

5. Expansion slot for Plugin module 

6. SD Card Slot

Fig. 5.1

Connections

eTOP605

Содержание eTOP507G

Страница 1: ...Exor International S p A MANUGENETOP6xx Ver 1 03 eTOP Series 600 Operating Instructions Basic User s Manual for eTOP Series 600 Touchscreen Products ...

Страница 2: ...t notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it is provided as is without warranty of any kind Third party brands and names are the property of their respective owners www exorint net ...

Страница 3: ...10 4 1 Dimensions 12 4 2 Installation Environment 14 4 3 Safety instruction 15 4 4 Installation Procedure 15 5 Connections 16 5 1 Serial Port 18 5 2 Ethernet Port 18 5 3 Optional plugin module 19 5 4 Optional plugin module installation procedure 23 6 Power Supply Grounding and Shielding 24 7 Battery 25 8 Cleaning Faceplates 26 9 Getting Started 26 10 System Settings 27 12 Unpacking and Packing Ins...

Страница 4: ...use and maintenance This Operating Instruction describes the main features of the Exor operator panels The Manual refers to the following models eTOP605 Operator interface with TFT color 5 widescreen display touchscreen eTOP607M Operator interface with TFT color 7 widescreen display touchscreen 1GHz CPU eTOP610 Operator interface with TFT color 10 1 widescreen display touchscreen Introduction ...

Страница 5: ...divided into three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure to observe safety rules and that deficiency may cause damage CAUTION indicates a failure to observe safety rules and that deficiency may cause defects to the equipment or inconsistencies CAUTION ATTENTION DANGER Safety Guide ...

Страница 6: ... meet global requirements Far East languages are supported Tools available in JMobile Studio support easy third party translations and help reducing development and maintenance costs of the application Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art HMI features data acquisition alarm handling scheduler and timed actions daily and weekly...

Страница 7: ...e devices into the residential commercial and light industrial environments is allo wed only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 The products are in compliance with the Restrictions on Certain Hazardous Substances RoHS Directive 2002 95 EC In compliance with the above regulations the products are CE marked Special instruction for use The equ...

Страница 8: ...Note the eTOP607M label is used as an example for eTOP600 Series product model name eTOP607M product part number ETOP607MU5P1 month year of production 05 16 serial number 09994847559 version id of the product 091003B03101000 manufacturer address and Exor International S p A read instruction warning Via Monte Fiorino 9 IT 37057 San Giovanni Lupatoto VR ATEX Marking DEMKO 16 ATEX 1683X II 3G Ex nA I...

Страница 9: ...isturbances inducted by radiofrequency field 0 15 80 MHz 10V EN 61000 4 6 Voltage dips short interruptions and voltage variations immunity test Port AC mains Level 100 duration 1 cycle and 250 cycles 50Hz 40 duration 10 cycles 50Hz 70 duration 25 cycles 50Hz Phase 0 180 Test executed on the 230Vac side of the Exor International S p A Power Supply EN 61000 4 11 Operating and storage humidity 5 85 R...

Страница 10: ... Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated switch USB port 1 Host interface version 2 0 and 1 1 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion slot 1 Optional Plugin 2 Optional Plugin Battery rechargeable rechargeable Real Time Cloc...

Страница 11: ...vailable memory Serial Port RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch USB port 2 Host interface 1 version 2 0 1 version 2 0 and 1 1 Expansion slot 2 Optional Plugin Battery rechargeable Real Time Clock yes Voltage 24Vdc Current rating at 24VDC 1 00A Weight 1 7 Kg 10 32Vdc For applications requiring compliance with EN 61131 2 and specif...

Страница 12: ...12 MANUGENETOP6xx Operating Instructions VER 1 03 4 1 Dimensions Technical Data Cut out MODEL A B C D E F eTOP605 147mm 5 78 107mm 4 21 136mm 5 35 96mm 3 78 56mm 2 40 8mm 0 31 ...

Страница 13: ...x Operating Instructions VER 1 03 Technical Data Cut out MODEL A B C D E F eTOP607M 187mm 7 36 147mm 5 79 176mm 6 90 136mm 5 35 47mm 1 85 8mm 0 31 eTOP610 282mm 11 1 197mm 7 80 271mm 10 67 186mm 7 32 56mm 2 20 8mm 0 31 ...

Страница 14: ...rder to meet the front panel protection classifications proper installation procedure must be followed the borders of the cutout must be flat screw up each fixing screw until the bezel corner get in contact with the panel the cutout for the panel must be of the dimensions indicated in this manual The IP66 is guaranteed only if max deviation from the plane surface to the cut out O0 5mm thickness of...

Страница 15: ...ackets contained in the fixing kit as shown in figure Technical Data 4 3 Safety instruction For all installation notes please refer to the Installation Guide provided with the product CAUTION Tightening torque 130Ncm or screw each fixing screw until the bezel corner gets in contact with the panel ...

Страница 16: ...16 MANUGENETOP6xx Operating Instructions VER 1 03 5 Connections 1 Serial Port 2 2x Ethernet Port 3 USB Port 4 Power Supply 5 Expansion slot for Plugin module 6 SD Card Slot Fig 5 1 Connections eTOP605 ...

Страница 17: ...Instructions VER 1 03 1 Serial Port 2 2x Ethernet Port 3 USB Port version 2 0 1 1 4 USB Port version 2 0 High speed only 5 Power Supply 6 2x Expansion slot for Plugin module 7 SD Card Slot Fig 5 2 Connections eTOP607M and eTOP610 ...

Страница 18: ...ce in the programming software The communication cable must be chosen for the type of device being connected Connections SERIAL PORT RS 232 RS 422 RS 485 To operate in RS485 pins 4 3 and 8 7 must be connected externally Pin Description 1 GND 2 3 TX 4 RX 5 6 5V output 7 CTS 8 RTS 9 Pin Description 1 GND 2 3 CHA 4 CHB 5 6 5V output 7 CHB 8 CHA 9 5 2 Ethernet Port 1 8 OFF Valid link has NOT been dete...

Страница 19: ...interface 1 CAN interface 1 SPI interface Note It is not possible to stack two modules that are using the same type of interface Below you can find relation between modules ATEX and IECEx marked and max number of modules that can be used into eTOP600 serie panels based on their Interface Type Module Application Max Modules Interface Type Bus Extension connector PLCM01 CAN 1 for eTOP507G 2 for eTOP...

Страница 20: ...ear of production 05 16 serial number 09994847559 version id of the product 050100A00000000 manufacturer address and Exor International S p A read instruction warning Via Monte Fiorino 9 IT 37057 San Giovanni Lupatoto VR ATEX Marking DEMKO 16 ATEX 1683X II 3G Ex nA IIC T4 Gc 20 Tamb 60 C II 3D Ex tc IIIC T105 C Dc IECEx Marking IECEx IECEx ULD 16 0007X Ex nA IIC T4 Gc 20 Tamb 60 C Ex tc IIIC T105 ...

Страница 21: ... tc IIIC T105 C Dc IECEx Marking IECEx IECEx ULD 16 0007X Ex nA IIC T4 Gc 0 Tamb 50 C Ex tc IIIC T105 C Dc PLCM01 PLCM01 NE Operating temperature 20 C to 60 C PLCM05 Operating temperature 20 C to 60 C PLIO03 Operating temperature 0 C to 50 C vertical installation 12 30VDC PLCM01 PLCM05 and PLIO03 electrical ratings PLCM01 For electrical rating refers to the host eTOP600 models PLCM05 For electrica...

Страница 22: ...are planning to use two PLCM01 CAN interface you will obtain following Slot association a module plugged in Slot 1 or into Slot 2 will be the CanPort 0 a module plugged in Slot 3 or into Slot 4 will be the CanPort 1 Below you can find relation between modules and max number of modules that can be used into eTOP600 serie panels based on their Interface Type Module Application Max Modules Interface ...

Страница 23: ...23 MANUGENETOP6xx Operating Instructions VER 1 03 5 4 Optional plugin module installation procedure PLCM PLIO03 ...

Страница 24: ...ction Also connect to ground the terminal 3 on the power supply terminal block The power supply circuit may be floating or grounded In the latter case connect to ground the power source common as shown in figure see below with a dashed line When using the floating power scheme note that the panes internally connects the power common to ground with a 1MΩ resistor in parallel with a 4 7nF capacitor ...

Страница 25: ...g information is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures a period of 3 months of data back up at 25 C Battery ATTENTION Dispose of batteries according to local regulations Battery Battery Fig 7 1 eTOP605 Fig 7 2 eTOP607M eTOP610 ...

Страница 26: ...t must be properly installed on a computer running Microsoft Windows There are two options to transfer a JMobile application project to a HMI device Ethernet Connect the HMI device to the computer with an Ethernet network connection From JMobile Studio choose the command Run Download to target You may have to ensure that the proper firewall policy has been configured in the computer to allow JMobi...

Страница 27: ...start the associated function System Settings has two modes of operation User Mode JMobile runtime is running or the HMI device is in factory default status System Mode JMobile runtime is not running or the HMI device has a software failure System Mode includes all options available in User Mode and offers in additions commands dedicated to system upgrade and recovery Activation of System Settings...

Страница 28: ...dules are installed Network configure IP Address of Ethernet interface BSP settings show the BSP Board Support Package version check the operating hours for the device and for the display backlight manage the buzzer Time change the device date and time including time zone Daylight Saving Time and NTP Server Regional Settings customize Windows Regional Settings such as date format Display settings ...

Страница 29: ...der reserved to authorized technical personnel Upload Configuration OS reserved to authorized technical personnel Upload Main OS reserved to authorized technical personnel Upload Splash Image copy to an USB Memory or SD Card the current splash screen image in binary format Upload OS Partition reserved to authorized technical personnel Upload Data Partition reserved to authorized technical personne...

Страница 30: ...30 MANUGENETOP6xx Operating Instructions VER 1 03 12 Unpacking and Packing Instructions Unpacking and Packing Instructions to repack the unit please follow the instructions backwards ...

Отзывы: