Warning

To minimise the risk of fire, electric shock, personal injury 

and/or damage to the product please observe the following:

•   Please always read the manual and only use the product in accordance with the 

manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.

• 

 All installations must be carried out by properly qualifi ed personnel in accordance with 

national legislation and regulations.

• 

This product must be earthed. Get assistance from an qualifi ed electrician when in doubt. 

• 

The chimney fan must always remain switched on when the fireplace is in use.

• 

Ensure that the chimney has been swept before mounting the fan to avoid chimney fires.

•   Prior to servicing the product, disconnect the power and ensure that it cannot accidentally 

be reconnected.

• 

 Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is 

installed.

•   If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please 

ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-

ved, a smoke alarm must be installed in the same room as the heat appliance.

•   Note! Fans serving biomass boilers must be cleaned more often due to extensive residue/

soot building. It is essential that a regular inspection and cleaning schedule is implemen-

ted, especially in the early days of usage, to experience how often regular inspections and 

cleaning should be carried out.

UK

Your energy. 

Optimized.

Product information

An Exodraft chimney fan RSG/RSGC provide a controllable negative pressure along the full length of the 

flue and chimney. A fail-safe system is fitted in the fan which automatically measures the velocity of the 

flue gases.
Only when the velocity exceeds the preset and safe level can the gas appliance be used. The fail-safe 

system prevents any spillage from the gas appliance as well as any leaks of CO and other poisonous gases.

Fan type RSG/RSGC is installed on the external wall and thereby enables a gas appliance to be installed in 

a room with no chimney. 

The power of the fan will allow for long horizontal flues up to 15 meters. A silencer type SLR is available as 

an accessory for the fan type RSG.

The RSG type fan is used as part of the fail-safe flue system for open flued gas appliances, such as stoves 

and domestic boliers. The RSGC type fan is used as part of a fail-safe flue system for closed appliances 

such as cookers and oil-fired and gas-fired boilers. All gas appliances must be CE-certified.

The fan is part of an Exodraft system and should be connected to an EFC21 Exodraft controller for 

optimal effect. 

Please always read the installation instructions for the Exodraft control unit, before installation of the

 

chimney fan.

Incorrect firing may result in problems with soot, chimney fires, etc. which might damage the product. 

Please check out this site for advice about lighting and maintaining a fire:

www.exodraft.com

 

Scope of supply

• 

Exodraft RSG chimney fan

•  Installation manual and user instructions

Accessories and spare parts

The table below shows the accessories and spare parts available for the RSG-models.

Accessories*

Spare parts

Silencer SLR**

Motors

Impellers and axial vanes

Pressure differential switch (PDS)

*Normally Exodraft manuals does not describe the specific use of accessories. We refer to the separate manuals for such components. 

 

For more details contact your Exodraft dealer.

**But this manual describe the use of the silencer SLR for the RSG-models. 

 

Содержание RSG

Страница 1: ...Your energy Optimized Chimney Fan RSG UK Read and save these instructions ...

Страница 2: ......

Страница 3: ...lation 13 Location of the fan 13 Installation of the silencer 14 Installation of the fan 15 Electrical installation 17 Spillage test and pressure differential switch 18 Reduced fan speed 18 Startup and configuration 19 System testing 19 Operating the fireplace using the EFC21 controller 19 Maintenance and troubleshooting 20 Troubleshooting 21 UK Conformity Assessed 22 Declaration of Conformity 23 ...

Страница 4: ...r waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste How to use this manual This manual has been prepared based on the specific product and contains relevant technical information and installations guides Accessories and spare parts are not covered by this manual Please refer to the individual manuals of these compo...

Страница 5: ...rks a dangerous situation that in the worst case scenario can cause serious personal injury or significant damage to the product Electricity hazard High Voltage Marks a situation in which caution is advised due to the risk of high voltage electric shock which can cause serious personal injury or significant damage to the product Connect an earth terminal to the ground Failure to observe instructions...

Страница 6: ...before mounting the fan to avoid chimney fires Prior to servicing the product disconnect the power and ensure that it cannot accidentally be reconnected Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is installed If the Exodraft fan system has been designed for solid fuel multi fuel installations please ensure that the design meets the requirements of BS EN15287 1 If...

Страница 7: ... a fail safe flue system for closed appliances such as cookers and oil fired and gas fired boilers All gas appliances must be CE certified The fan is part of an Exodraft system and should be connected to an EFC21 Exodraft controller for optimal effect Please always read the installation instructions for the Exodraft control unit before installation of the chimney fan Incorrect firing may result in...

Страница 8: ... not been tested approved with the product Any damage resulting from continued use of the product despite an evident defect Failure to use original spareparts and accessories Failure to use the product as intended Exceeding or failure to meet the limit values in the technical data Force majeure Technical specifications The Exodraft chimney fan type RSG gives a downward discharge of the flue gases ...

Страница 9: ... 560 247 60 516 556 271 279 Model Motor specifications Weight rpm V Amp kW kg RSG125 41 1400 1 x 230 0 3 0 04 11 RSG150 41 1400 1 x 230 0 2 0 05 14 RSG200 41 1400 1 x 230 0 4 0 11 20 RSGC150 41 1400 1 x 230 0 8 0 14 31 Effect at the motor shaft at ambient temperature 20 C RPM is infinitely adjustable for all 1x230 V motors The motor is overload protected Motor protection class IP 54 Insulation cla...

Страница 10: ... differential switch PDS 5 Hinged outer door 6 Air flow sensor 7 Air flow sensor 8 Cooling impeller 9 Screw to open hinged inner door 10 Screw to open hinged outer door 11 Outlet grill 12 Flow reducing plate 13 Screw for flow reducing plate 14 Label Stay clear of hot surface 3 1 2 11 14 12 13 4 10 7 6 5 9 8 1 2 ...

Страница 11: ...und and has a length of min 280 mm Its outer housing is made of galvanised sheet metal insulated by mineral wool to a thickness of 50 mm with a perforated inner steel sleeve There are four types of SLR Type M N O P SLR125 280 Ø128 Ø125 Ø240 SLR150 280 Ø153 Ø150 Ø265 SLR200 280 Ø206 Ø203 Ø318 SLR250 280 Ø256 Ø253 Ø370 N M O P FAN ...

Страница 12: ...le material The silencer and the flue pipe should not be in contact with any inflammable material when it is instal led in the wall When the fan is installed in a timber framed house the recommendations of Institute of Gas Engineers publication UP 7 Gas installations in timber framed buildings should be observed RSG and RSGC fans are not to be installed with solid fuel appliances With DFE fireplac...

Страница 13: ... final location of the appliance Check that the fan posi tion on the external wall is acceptable Mark the centre of the flue exit on the internal wall Use this centre to make cutting lines for the flue pipe or silencer using dimensions for fan RSG150 and 200 as applicable The hole through the wall should provide minimum 5 mm clearance between the wall and the flue pipe or silencer Drill and cut th...

Страница 14: ...wall It is possible to use two of the holes and screws which are used to secure the fan If the silencer is longer than the wall unscrew the retaining screws at the end of the silencer Lift off the end plate Cut the outer and inner pipe so the length fits the wall thickness Trim off excess mineral wool insulation and mount the inlet plate Continue the installation as described below ...

Страница 15: ...Use flue cement to make airtight connections 4 Make sure that the gas seal if any fits tightly around the silencer the fan is mounted with the outlet facing downwards 5 Pack 50 mm mineral wool around the part of the flue pipe which is located in the wall The cavity between the outer and the inner brick leaf and the space between the brick walls and the silencer should be filled with mineral wool 6...

Страница 16: ...g plate must be located in the chimney approximately 100 mm above the hole for the chimney box The sealing plate should be firmly inserted into the flue wall and properly sealed It must be established that there are no leaks Install the fan without the silencer ...

Страница 17: ...must always have an isolation switch fitted The isolation switch must comply with national wiring standards The isolation switch must be ordered separately as it is not part of the standard Exodraft chimney fan delivery Please refer to Machine Directive 2006 42 EF EEC EWG CEE Appendix 1 item 1 6 3 Separation of the sources of energy Exodraft motor Grundfos motor 8 7 6 5 4 3 2 1 AUX MAIN P BN BK BU...

Страница 18: ... 41 60 Pa RSGC150 41 Fix 10 20 Pa WARNING Turn the fan off at the isolation switch before commisioning is startet ATTENTION Open the fan cover for setting the PDS Start and run the fan as described in the control manual Be aware that the cooling vane on the motor is running Reduced fan speed If Then the RMS voltage to fan motor is under 160 V The outlet grill can be adju sted in order to enable th...

Страница 19: ...iance water heater furnace etc is working properly after the chimney fan has been switched on Make sure that no flue gases are spilling out as this can lead to carbon monoxide poisoning Press the ON OFF button The operating LED B will flash GREEN until the correct chimney draught is confirmed If it flashes YELLOW then the Air inlet must be opened The operating LED will then become GREEN and the fi...

Страница 20: ...ction It is recommended that the fan and its connections should be inspected once a year at the same time as the annual maintenance of the appliance Remove all soot deposits on the impeller and the sensors On inspection care should be taken that the flow measuring system is not damaged In open position the hinged chimney fan provides easy access for service and maintenance WARNING Do not open the ...

Страница 21: ...he axial vane impeller stick Check capacitor and replace if necessary Clean the fan The fan seems to work fine but there is not enough draught The fan may be undersized The capacitor may be worn out The flue is damaged blocked Replace with a larger fan Check capacitor and replace if necessary Check the flue chimney sweep The fan vibrates The motor shaft may be bent The fan needs cleaning Incorrect...

Страница 22: ...re manufactured in conformity with the provisions of the following regulations The Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 Langeskov 01 11 2022 Managing Director Anders Haugaard UK Conformity Assessed RSG150 41 RSG200 41 ...

Страница 23: ...klaration överensstämmer med följande standard er Jota tämä selvitys koskee on seuraavien standardien mukainen Sem eru meðtalin i staðfestingu Pessari eru i fullu samræmi við eftirtalda staðla Sono stati fabbricati in conformità con le norme degli standard seguenti EN 60335 1 EN 60335 2 80 DS EN ISO 12100 2011 I h t bestemmelser i direktiv In accordance with Entsprechen gemäß den Bestimmungen der ...

Страница 24: ...nfo exodraft no www exodraft no UK Exodraft Ltd 24 Janes Meadow Tarleton GB Preston PR4 6ND Tel 44 0 1494 465 166 Fax 44 0 1494 465 163 info exodraft co uk www exodraft co uk DE Exodraft a s Niederlassung Deutschland Soonwaldstr 6 DE 55569 Monzingen Tel 49 0 6751 855 599 0 Fax 49 0 6751 855 599 9 info exodraft de www exodraft de FR Exodraft sas 78 rue Paul Jozon FR 77300 Fontainebleau Tel 33 0 6 3...

Отзывы: