UK |
7
3112007_RSG_UK
Warning
To minimise the risk of fire, electric shock, personal injury
and/or damage to the product please observe the following:
• Please always read the manual and only use the product in accordance with the
manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.
•
All installations must be carried out by properly qualifi ed personnel in accordance with
national legislation and regulations.
•
This product must be earthed. Get assistance from an qualifi ed electrician when in doubt.
•
The chimney fan must always remain switched on when the fireplace is in use.
•
Ensure that the chimney has been swept before mounting the fan to avoid chimney fires.
• Prior to servicing the product, disconnect the power and ensure that it cannot accidentally
be reconnected.
•
Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is
installed.
• If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please
ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-
ved, a smoke alarm must be installed in the same room as the heat appliance.
• Note! Fans serving biomass boilers must be cleaned more often due to extensive residue/
soot building. It is essential that a regular inspection and cleaning schedule is implemen-
ted, especially in the early days of usage, to experience how often regular inspections and
cleaning should be carried out.
UK
Your energy.
Optimized.
Product information
An Exodraft chimney fan RSG/RSGC provide a controllable negative pressure along the full length of the
flue and chimney. A fail-safe system is fitted in the fan which automatically measures the velocity of the
flue gases.
Only when the velocity exceeds the preset and safe level can the gas appliance be used. The fail-safe
system prevents any spillage from the gas appliance as well as any leaks of CO and other poisonous gases.
Fan type RSG/RSGC is installed on the external wall and thereby enables a gas appliance to be installed in
a room with no chimney.
The power of the fan will allow for long horizontal flues up to 15 meters. A silencer type SLR is available as
an accessory for the fan type RSG.
The RSG type fan is used as part of the fail-safe flue system for open flued gas appliances, such as stoves
and domestic boliers. The RSGC type fan is used as part of a fail-safe flue system for closed appliances
such as cookers and oil-fired and gas-fired boilers. All gas appliances must be CE-certified.
The fan is part of an Exodraft system and should be connected to an EFC21 Exodraft controller for
optimal effect.
Please always read the installation instructions for the Exodraft control unit, before installation of the
chimney fan.
Incorrect firing may result in problems with soot, chimney fires, etc. which might damage the product.
Please check out this site for advice about lighting and maintaining a fire:
www.exodraft.com
Scope of supply
•
Exodraft RSG chimney fan
• Installation manual and user instructions
Accessories and spare parts
The table below shows the accessories and spare parts available for the RSG-models.
Accessories*
Spare parts
Silencer SLR**
Motors
Impellers and axial vanes
Pressure differential switch (PDS)
*Normally Exodraft manuals does not describe the specific use of accessories. We refer to the separate manuals for such components.
For more details contact your Exodraft dealer.
**But this manual describe the use of the silencer SLR for the RSG-models.