![Exodraft RS009-4-1 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/exodraft/rs009-4-1/rs009-4-1_owners-manual_2451395031.webp)
Fitting the chimney fan onto the chimney
Step
Action
1
The chimney fan is now ready for mounting. Place the glass
ibre mat on top of the chimney, the aluminium foil facing
upwards, and place the chimney fan on top of the mat.
2
Mount the safety wire in the chimney (1). Use the supplied
screw and rawl-plug in brick chimney and the self-cutting
screw in steel chimney. Then mount the wire through the
hole in the base plate and into the wire lock.
Tighten the safety wire slightly and tighten the wire lock (2),
so that the chimney fan is secured when opened for service
and cleaning purposes.
The isolation switch should be itted onto the side of the
chimney (3), so it is easily accessible when servicing the fan.
The armoured cable should be connected into the underside
of the isolator and up into the switch via the coupling.
3
Before starting up, make sure that:
• the nuts in the location brackets are tightened (4)
• the chimney fan is closed and the screw tightened (5)
• the safety wire is clamped to the chimney (6)
• the safety wire and the wire lock are tightened (7)
• the grommet on the armoured cable is fastened (8)
• the end-user is aware of the fact that the chimney fan must
always be operating when the ireplace/boiler is in use
3000112 RS DK DE NO SE UK NL FR 211014
UK •
31