background image

Your energy. 

Optimized.

Chimney Fan

GSV

UK

 

 |   Read and save these instructions!

Содержание GSV

Страница 1: ...Your energy Optimized Chimney Fan GSV UK Read and save these instructions...

Страница 2: ......

Страница 3: ...stallation 13 Transportation safety bracket 13 Minimum distance 14 Installation onto a brick chimney 15 Installation onto a steel chimney 17 Multiple fans on chimney 20 Electrical installation 21 Isol...

Страница 4: ...waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste How to use this manual This manual has been prepared based on th...

Страница 5: ...ks a dangerous situation that in the worst case scenario can cause serious personal injury or signi cant damage to the product Electricity hazard High Voltage Marks a situation in which caution is adv...

Страница 6: ...efore mounting the fan to avoid chimney res Prior to servicing the product disconnect the power and ensure that it cannot accidentally be reconnected Exodraft always recommends the use of a smoke alar...

Страница 7: ...ay result in problems with soot chimney fires etc which might damage the product Please check out this site for advice about lighting and maintaining a fire www exodraft com Scope of supply Exodraft G...

Страница 8: ...onnel Exodraft reserves the right to change these guidelines without prior notice The warranty and liability does not cover instances regarding personal injury or damage to property or the product tha...

Страница 9: ...fitted with a stainless steel grid as finger and bird protection The sound level is below 60 dB measured at a distance greater than 2 5 metre away from the fan if instal led correctly Further informat...

Страница 10: ...GSV400 41 1400 1 x 230 2 60 0 60 47 430 650 525 400 130 GSV400 42 1720 3 x 400 3 50 0 75 52 460 650 525 400 130 Power consumption at ambient temperature of 20 C Frequency inverter is required The RPM...

Страница 11: ...xial vane centrifugal impeller 6 Safety hinge 7 Safety mesh 8 Handle 9 Screws to fasten top and bottom section Alternatively use supplied wing screws where conditions allow 10 Armoured cable and conne...

Страница 12: ...eys do not usually need any kind of support to carry the weight of the chimney fan System type The chimney fan generates a vacuum in the flue pipe and in the chimney The grease fan is especially suita...

Страница 13: ...rsonnel and according to the manufacturer s instructions Transportation safety bracket Do not forget to remove the transport safety bracket located near the impeller and check that the axial vane impe...

Страница 14: ...vertically Be aware of national law and building regulations Minimum distance The minimum distance to flammable materials must be at least 500 mm national legislation must be observed RSV og GSV og RS...

Страница 15: ...temperature sensor is to be installed with the chimney fan cut a groove in the mineral wool mat that is big enough for the sensor 20 mm 20 mm 3 Mount and fasten the location brackets to the underside...

Страница 16: ...asily accessible when servicing the fan The armoured cable should be connected into the underside of the isolator and up into the switch via the cable gland R S V o g G S V o g R S V G 7 Before taking...

Страница 17: ...of the hole in the flange 2 Then cut a hole in the mineral wool mat that matches Note that there must always be a minimum of 20 mm of mat surface at any point around the circumference of the hole 20 m...

Страница 18: ...rgy Optimized 4 Fixate the flange to the chimney fan with the use of the vibration dampers supplied with the flange RSV og GSV og RSVG 5 The fan assembly can now be fitted onto the steel chimney RSV o...

Страница 19: ...S V o g R S V G 7 Before taking the fan into operation please make sure that the nuts in the location brackets have been tightened the safety wire has been fastened to the fan and chimney the safety...

Страница 20: ...emely important that the fans are of the same model and size and they must be controlled in tandem by one motor speed control A similar approach should be taken if the flue size exceeds the fan base d...

Страница 21: ...2 1 AUX MAIN L1 N POWER SUPPLY 1 x 230V 50Hz 3 x 0 75 YEGN Isolation switch In accordance with the provisions of the applicable EU Machinery Directive a chimney fan must always have an isolation switc...

Страница 22: ...s operating properly DANGER Check that the heating appliance water heater furnace etc is working properly after the chimney fan has been switched on Make sure that no flue gases are spilling out as th...

Страница 23: ...fessional chimney sweep Note The motor in the fan has ball bearings that are sealed lifetime lubricated and maintenance free Should replacement of the bearings be required this should be carried out b...

Страница 24: ...the axial vane impeller stick Check capacitor and replace if necessary Clean the fan The fan seems to work fine but there is not enough draught The fan may be undersized The capacitor may be worn out...

Страница 25: ...ufactured in conformity with the provisions of the following regulations The Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regu...

Страница 26: ...tion verensst mmer med f ljande standard er Jota t m selvitys koskee on seuraavien standardien mukainen Sem eru me talin i sta festingu Pessari eru i fullu samr mi vi eftirtalda sta la Sono stati fabb...

Страница 27: ......

Страница 28: ...fo exodraft no www exodraft no UK Exodraft Ltd 24 Janes Meadow Tarleton GB Preston PR4 6ND Tel 44 0 1494 465 166 Fax 44 0 1494 465 163 info exodraft co uk www exodraft co uk DE Exodraft a s Niederlass...