3.6
Vertical installation
To mount the CFI vertically, suspend the Inline fan with threaded rod. Once the position of the fan and rods is finalized,
hang 4 pieces of threaded rod through the mounting holes of the fan as shown in fig. 7. (On back side of fan, run
threaded rod through both top and bottom mounting holes.) Once the Inline fan is leveled, secure the rod with lock
washers and locking hex nuts.
M12 Threaded rod, lock washers
and locking hex nuts
(A tack weld may be placed on the hex nuts
for permanent fixation)
Fig. 7
3.7
Horizontal installation
To mount the CFI horizontally, suspend the Inline fan with threaded rod or steel hangers. It may be necessary to cross
brace the fan from end to end to prevent side sway. Ensure the fan is level before permanently securing.
HANG FAN FROM (4)
TOP MOUNTING HOLES
Fig. 8
NOTICE
If you incidently are able to touch the CFI in operation there should be mounted a cover to
prevent getting burnt.
3110067 CFI 300-500 UK 290415
8
•
Mechanical Installation
Содержание CFI 300
Страница 1: ...UK CFI 300 500 Inline fan Read and save these instructions...