Maintenance
DANGER
Jump starting a weak battery that is cracked,
frozen, has low electrolyte level, or an
open/shorted battery cell, can cause an
explosion resulting in serious personal injury.
Do Not jump start a weak battery if these
conditions exist.
2. Make sure the booster is a good and fully charged
lead acid battery at 12.6 volts or greater. Use
properly sized jumper cables (4 to 6 AWG) with
short lengths to reduce voltage drop between
systems. Make sure the cables are color coded or
labeled for the correct polarity.
CAUTION
Connecting the jumper cables incorrectly
(wrong polarity) can immediately damage the
electrical system.
Be certain of battery terminal polarity and
jumper cable polarity when hooking up
batteries.
Note:
The following instructions are adapted
from the SAE J1494 Rev. Dec. 2001 – Battery
Booster Cables – Surface Vehicle Recommended
Practice (SAE – Society of Automotive
Engineers).
WARNING
Batteries contain acid and produce explosive
gases.
•
Shield the eyes and face from the batteries
at all times.
•
Do Not lean over the batteries.
Note:
Be sure the vent caps are tight and level.
Place a damp cloth, if available, over any vent
caps on both batteries. Be sure the vehicles do
not touch and that both electrical systems are
off and at the same rated system voltage. These
instructions are for negative ground systems only.
3. Connect the positive (+) cable to the positive (+)
terminal of the discharged battery that is wired to
the starter or solenoid as shown in Figure 23.
Figure 23
1.
Positive (+) cable on discharged battery
2.
Positive (+) cable on booster battery
3.
Negative (–) cable on the booster battery
4.
Negative (–) cable on the engine block
5.
Booster battery
6.
Discharged battery
7.
Engine block
4. Connect the other end of the positive cable to the
positive terminal of the booster battery.
5. Connect the black negative (–) cable to the other
terminal (negative) of the booster battery.
6. MAKE THE FINAL CONNECTION ON
THE ENGINE BLOCK OF THE STALLED
VEHICLE (NOT TO THE NEGATIVE POST)
AWAY FROM THE BATTERY. STAND BACK.
7. Start the vehicle and remove the cables in the
reverse order of connection (the engine block
(black) connection is the first to disconnect).
Check Mower Blades
Service Interval: Before each use or daily
1. Stop engine, wait for all moving parts to stop, and
remove key. Engage parking brake.
2. Lift deck and secure in raised position as stated in
the
Clean Grass Build-Up Under Deck
section.
3. Inspect blades and sharpen or replace as required.
4. Reinstall the blades (if they were removed) in the
following order:
A. Install the splined bushing through the blade
with the bushing flange on bottom (grass)
side of blade.
32
Содержание PIONEER S-SERIES Operators
Страница 1: ...PIONEER S SERIES For Serial Nos 315 000 000 Higher Part No 4502 317 Rev A ...
Страница 49: ...Schematics Schematics Electrical Diagram 49 ...
Страница 50: ...Schematics Electrical Logic Schematic 50 ...
Страница 52: ...Notes 52 ...
Страница 53: ...Service Record Date Description of Work Done Service Done By 53 ...
Страница 54: ...54 ...