15
FIGURE 3
UPPER ROLL BAR INSTALLATION
3.3 SERVICE BATTERY
The machine is shipped with a filled lead acid battery.
3.3.1
Unhook seat latch and tilt seat up to gain access to the battery.
DANGER
POTENTIAL HAZARD
♦
Charging the battery may produce explosive gasses
WHAT CAN HAPPEN
♦
Battery gasses can explode causing serious injury.
HOW TO AVOID THE HAZARD
♦
Keep sparks, flames, or cigarettes away from battery.
♦
Ventilate when charging or using battery in an
enclosed space.
♦
Make sure venting path of battery is always open once
battery is filled with acid.
3.3.2
Check the voltage of the battery with a digital voltmeter. Locate the voltage reading
of the battery in the table below and charge the battery for the recommended time
interval to bring the charge up to a full charge of 12.6 volts or greater.
IMPORTANT:
Make sure the negative battery cables are disconnected and the
battery charger used for charging the battery has an output of 16 volts and 7
amps or less to avoid damaging the battery (see chart below for recommended
charger settings).
Voltage
Reading
Percent
Charge
Maximum
Charger Settings
Charging Interval
12.6 or greater 100%
16 volts/7 amps
No Charging Required
12.4 – 12.6
75 – 100%
16 volts/7 amps
30 Minutes
12.2 – 12.4
50 – 75%
16 volts/7 amps
1 Hour
12.0 – 12.2
25 – 50%
14.4 volts/4 amps
2 Hours
11.7 – 12.0
0 – 25%
14.4 volts/4 amps
3 Hours
11.7 or less
0%
14.4 volts/2 amps
6 Hours or More
WARNING:
Battery posts, terminals, and related accessories contain lead compounds, chemicals known
to the State of California to cause cancer and reproductive harm.
Wash
hands after handling.
Содержание Laser Z CT
Страница 1: ...For Serial Nos 540 000 Higher Part No 103 9180 ...
Страница 45: ...40 8 BRIGGS STRATTON ELECTRICAL DIAGRAM ...
Страница 46: ...41 9 HYDRAULIC DIAGRAM ...
Страница 48: ... 43 NOTES ...
Страница 49: ... 44 NOTES ...
Страница 50: ... 45 SERVICE RECORD Date Description of Work Done Service Done By ...
Страница 51: ... 46 ...