Operation
during transport to and from the jobsite, and when
parked inside a building.
Align valve handle with the fuel line to open. Rotate
90° to close.
Tine Down Pressure Control
Located on the left side of the control console (see
Figure 5).
Rotate the control counterclockwise to decrease the
pressure and the length of the aeration plug; rotate
clockwise to increase pressure and increase the length
of the aeration plug.
On/Off Tine Ground Engagement
Foot Switch
Located above the tine down pressure control on the
control console.
Push down on the top of the switch to enable the
tines ground engagement foot switch. Push down on
the rear of the switch to disable the foot switch..
Tines Ground Engagement Foot
Switch
Keep hands and feet away from the tines. Make
sure the tines area is clear of any obstructions
before lowering it.
Located on the operator platform (see Figure 5).
To lower the tines into the ground, stand on the
tine ground engagement switch. To raise the tines,
remove your foot from the switch.
Tine Down Pressure Gauge
Located in the middle of the control console.
The gauge displays the tine down pressure when
aerating.
Pre-Start
Fill fuel tank on level ground. See
Fuel
Recommendations
in the Specifications section for
additional gasoline information.
Do Not
add oil to gasoline.
Do Not
overfill fuel tank. Fill the fuel tank to the
bottom of the filler neck. The empty space in the
tank allows gasoline to expand. Overfilling may result
in fuel leakage or damage to the engine or emission
system.
Make sure you understand the controls, their
locations, their functions, and their safety
requirements.
Refer to the Maintenance section and perform all the
necessary inspection and maintenance steps.
Operating Instructions
Open the Fuel Shut-Off Valve
Rotate the valve and align with the fuel line to open.
Starting the Engine
1. Leave the motion control levers in neutral and
engage the parking brake.
2. Place the throttle midway between the “SLOW”
and “FAST” positions.
3. On a cold engine, push the choke lever forward
into the “ON” position. On a warm engine, leave
the choke in the “OFF” position.
4. Turn ignition switch to the “START” position.
Release the switch as soon as the engine starts.
Important:
Do Not crank the engine
continuously for more than ten seconds at a
time. If the engine does not start, allow a 60
second cool-down period between starting
attempts. Failure to follow these guidelines
can burn out the starter motor
5. If the choke is in the “ON” position, gradually
return choke to the “OFF” position as the engine
warms up.
Lowering the Tines
DANGER
The rotating tines under the engine deck are
dangerous. Tine contact can cause serious injury
or kill you.
Do Not put hands or feet under the unit when
the engine is running.
1. Set throttle to “MIDWAY” position.
2. Step on the tine ground engagement foot switch
to lower the tines. Stand on the switch and move
the motion control levers forward to aerate.
19
Содержание ARX481CKA30000
Страница 1: ...STAND ON AERATOR For Serial Nos 315 000 000 Higher Part No 4502 175 Rev A...
Страница 40: ...Schematics Schematics Electrical Diagram 40...
Страница 41: ...Schematics Electrical Schematic 41...
Страница 42: ...Schematics Hydraulic Diagram 42...
Страница 44: ...Notes 44...
Страница 45: ...Service Record Date Description of Work Done Service Done By 45...
Страница 46: ...46...