Maintenance
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6 or
greater
100%
16 volts/7
amps
No
Charging
Required
12.4 – 12.6
75–100%
16 volts/7
amps
30 Minutes
12.2 – 12.4
50–75%
16 volts/7
amps
1 Hour
12.0–12.2
25–50%
14.4 volts/4
amps
2 Hours
11.7–12.0
0–25%
14.4 volts/4
amps
3 Hours
11.7 or less
0%
14.4 volts/2
amps
6 Hours or
More
Check Safety Interlock
System
Service Interval: Before each use or daily
Note:
To prevent engine cut-outs on rough terrain
the seat kill switch has a 1/2 second delay.
1. Check starting circuit. Starter
should
crank with,
parking brake
engaged
, PTO
disengaged
and
motion control levers moved out in the
neutral
lock
position. The operator does not need to be
in the seat to start the engine.
Try to start with
operator in seat
, parking brake
disengaged, PTO disengaged and motion control
levers in the
neutral lock
position - starter
must
not crank
.
Try to start with
operator in seat
, parking brake
engaged, PTO
engaged
and motion control
levers in the
neutral lock
position - starter
must
not crank
.
Try to start with
operator in seat
, parking
brake
engaged
, PTO
disengaged
,
and the left
motion control lever in
, starter
must not crank
,
repeat again with the
right lever in
, then with
both levers in
- starter
must not crank
.
2. Check the kill circuits. Run engine at one-third
throttle,
disengage
parking brake and
raise off
of seat (but do not get off of machine) engine
must initiate shutdown
after approximately 1/2
second has elapsed (seat has time delay kill switch
to prevent cut-outs on rough terrain).
Run engine at one-third throttle,
engage PTO
and
raise off
of seat (but do not get off of
machine) engine
must initiate shutdown
after
1/2 second has elapsed.
Run engine at one-third throttle, with brake
disengaged, move levers in and raise off seat (but
do not get off of machine) engine must
initiate
shutdown
after 1/2 second has elapsed.
Again, run engine at one-third throttle, brake
engaged
, and move
left motion control lever in
- engine
must initiate shutdown.
Repeat again moving the
right lever in
, then
moving
both levers in
- engine
must initiate
shutdown
whether operator is
on seat or not
.
3. Check the PTO circuit. See the FR524, FR604,
and FR724 Operator’s manual to become familiar
with the deck operation. Open the folding
deck latches,
disengage
the park brake, move
the motion control levers in to
neutral
, and
disengage
the PTO.
Lower
the deck until the
PTO switch arm is no longer depressing the PTO
“kill” switch (see Figure 8).
Figure 8
Left Side—Inside of Hitch Shown
1.
PTO “Kill” Switch
2.
PTO Switch Arm
3.
Lower deck until arm Does Not contact the switch.
Run the engine at half throttle and
pull
up on the
PTO engagement switch.
The
PTO must not engage
.
25
Содержание 000 & Higher Serial Nos.
Страница 1: ...FRONTRUNNERTM AIR COOLED MODELS For Serial Nos 720 000 Higher Part No 4500 218 Rev A...
Страница 11: ...Safety 103 7218 107 2102 107 2112 109 2355 109 2356 1 Fast 3 Neutral 2 Slow 4 Reverse 11...
Страница 13: ...Safety 109 7413 1 Cylinder extend 4 Slow 2 Cylinder retract 5 Choke on 3 Fast 6 Choke off 109 7949 109 2360 13...
Страница 42: ...Service Record Date Description of Work Done Service Done By 42...
Страница 43: ...43...