Exinda Network Orchestrator
5 Troubleshooting
|
550
Go to
Monitor > Real Time Conversations
, and select the
Show Policies
option
This groups the traffic by the virtual
circuit and policy. Look for the desired traffic in expected policy. If the traffic is being accelerated by TCP, the
background colour is yellow. If the traffic is being processed by CIFS acceleration the CIFS acceleration icon is shown.
If a client had already established a connection with the server when the SMB acceleration service was restarted, file
transfers over that connection cannot take advantage of the acceleration.
There are two options for terminating the connection between the client computer and the server: Restart the client
computer or on a MS Windows client computer, navigate to
Control Panel > Administrative Tools > Services
, and
restart the Workstation service.
Any of the
Troubleshoot issues with TCP acceleration
considerations may be applicable.
You can also attempt to diagnose the issue by viewing the system log or the system diagnostics information.
The system diagnostics for acceleration can be filtered for SMB acceleration, WAN memory, or TCP acceleration.
The system log file can be filtered for SMB acceleration (smbad), WAN memory (wmd), TCP acceleration (tcpad), or
community (communityd).
For more information, refer to
5.6 Troubleshoot issues with Active Directory configuration
If you are experiencing issues with the Active Directory integration, these troubleshooting topics may help resolve the
issue.
5.6.1 Exinda Appliance Reboots Every Night
5.6.2 WMI Service is not running
5.6.3 System account showing in traffic reports
5.6.4 No Communication Between the Exinda AD Connector and the Exinda Appliance
5.6.5 Exinda AD Connector stops running
5.6.6 Excluded Users Still Appear on the Exinda Appliance
5.6.7 Changes to the Exinda Active Directory Controller have no effect
5.6.8 The IP addresses are not being mapped to the AD users and groups
5.6.1 Exinda Appliance Reboots Every Night
Problem
When multiple installations of the Exinda AD Connector have the
Send Active Directory user and group information
to Exinda appliance(s) at startup
option selected, the Exinda Appliance can become overwhelmed with duplicate data
from the connectors, which can cause the appliance to shut down.
Solution
1.
On each instance of the Exinda AD Connector, check whether the
Send Active Directory user and group inform-
ation to Exinda appliance(s) at startup
option is selected.
2.
If the option is selected on more than one instance, deselect the option on all Exinda AD Connectors.
Содержание EXNV-10063
Страница 98: ...Exinda Network Orchestrator 2 Getting started 98 6 Click New The New Virtual Hard Disk wizard opens ...
Страница 99: ...Exinda Network Orchestrator 2 Getting started 99 7 Select VHDX as the Disk Format type and click Next ...
Страница 130: ...Exinda Network Orchestrator 2 Getting started 130 Screenshot 35 The life cycle of configuration status ...
Страница 369: ...Exinda Network Orchestrator 4 Settings 369 ...
Страница 411: ...Exinda Network Orchestrator 4 Settings 411 Screenshot 168 P2P OverflowVirtualCircuit ...
Страница 420: ...Exinda Network Orchestrator 4 Settings 420 Screenshot 175 Students OverflowVirtualCircuit ...
Страница 451: ...Exinda Network Orchestrator 4 Settings 451 ...