background image

 

NFO

 

Drives

 

AB

 

2021

 

4

 

201016

2

 

Quick

 

Installation

 

Guide

 

Keyboard and menu summary 

Button 

Function 

Enter into parameter or parameter-group. 
Save parameter. 

Enter/toggle between normal screen and setup 
menu tree. 
Leave parameter, parameter-group or leave 
parameter unsaved. 

Toggle Operating mode between 

Manual

 and 

Auto

.  

Starts motor in 

Auto

 mode if Run signal active. 

Starts motor in 

Manual

 mode.  

Stops motor in all modes. 
NOTE: A bus master may start motor at any time 

Increase parameter when changing. 
Moves between parameter-groups or parameters. 

Decrease parameter when changing. 
Moves between parameter-groups or parameters. 

Motor  Ramp 

Run  Control  Freq. 

Speed  PI-reg  Output  Comm.  Status  Temp.  Display  Count.  Version  Error 

P-Nom

Accel 

Time 

Phase 

order 

Control 

mode 

Operate 

mode 

Operate 

mode 

Operate 

mode 

Relay 1 

Mode 

RS485 

bustype 

U-rms

Motor 

temp 

Display 

par.1 

Operate 

time 

CoProc 

version 

Error-log 

U-Nom

Decel 

Time 

Stop 

mode 

Auto- 

start 

FixFrq1 FixSpd1 FixReg1 

Relay 1 

Freq 

RS485 

addr 

I-rms

Power 

module 

Display 

par.2 

Run 
time 

DSP 

version 

Restart 

Delay 

f-Nom

Ramp 

Brkpoint 

Energy 

save 

A.input

1 type

FixFrq2 FixSpd2 FixReg2 

Relay 2 

Mode 

RS485 

baud 

P-out

COP 
temp 

Display 

par.3 

Brake 

time 

GUI 

version 

Reset 

Time 

N-Nom

Alt. 

Accel 

Pwr On 

delay 

A.input

2 type

FixFrq3 FixSpd3 FixReg3 

Relay 2 

Freq 

RS485 

char 

PF 

Heat 

sink 1 

Bklight 

level 

Cur.lim 

time 

Prod 

date 

AC Fail 

I-Nom

Alt. 

Decel 

Run 

delay 

D.input

config

FixFrq4 FixSpd4 FixReg4 

Aout 1 

Mode 

RS485 

timeout 

DC Link 

Heat 

sink 2 

Bklight 

timeout 

DC low 

time 

Serial 

number 

Temp Hi 

cos 

 

Stop 

delay 

 FixFrq5 

FixSpd5 

FixReg5 

Aout 1 

Max 

RS485 

autostop 

Brake 

chop 

Heat 

sink 3 

Menu 

readonly 

Start 

count 

PTC 

Temp 

Tuning

DC 

brake 

 FixFrq6 

FixSpd6 

FixReg6 

Aout 2 

Mode 

RS485 

failsafe 

Stator 

freq. 

Heat 

sink 4 

Alarm 

count 

Over 

load 

R-stator

Kp 

speed 

 FixFrq7 

FixSpd7 

FixReg7 

Aout 2 

Max 

USB 

bustype 

Rotor 

freq. 

Fan 1 

volt 

Output 

Energy 

 Ain 

Fail 

R-rotor

Ti  

speed 

A.input

min freq

A.input

min rpm

Setpoint 

min 

Analog 

1 out 

USB 
addr 

Control 

freq. 

Fan 2 

volt 

Total 

Energy 

 DC 

Low 

L-main

Sleep 

freq. 

A.input

max freq 

A.input

max rpm

Setpoint 

max 

Analog 

2 out 

USB 

timeout 

Rotor 

speed 

Fan 3 

volt 

DC 

High

Sigma

Bypass 

freq. 

Actual 

min 

USB 

autostop 

Control 

speed 

Fan 4 

volt 

GND 

Fail 

I-magn

Bypass 
bandw. 

Actual 

max 

ABCC 

interface 

Actual 

Torque 

EXT 

24V 

Short 

Circuit 

I-limit

Boost 

time 

Setp  

min limit 

ABCC 

bustype 

Control 
Torque 

USB  

5V 

Imagn 

Low 

Pole 

Count 

Boost 

level 

Setp 

max limit 

ABCC 

addr 

Actual 
PI-reg 

Current 

Low 

T-nom

Reg  
sign 

ABCC 

timeout 

Setpoint 

Pi-reg 

Current 

High 

Tuned 

status 

Reg 

Kp 

ABCC 

autostop 

Ain 1 V 

Current 

Limit 

Reg  

Ti 

Auto 

reset 

Ain1 

mA

Run 

Fail

Min 

freq

Ain 

V

Max 

freq

Ain2 

mA

Unit

Keybrd.

Off 

limit

Terminal

On 

limit

3006468-2022-04

Отзывы: