NFO
Drives
AB
2021
4
201016
‐
2
Quick
Installation
Guide
Keyboard and menu summary
Button
Function
Enter into parameter or parameter-group.
Save parameter.
Enter/toggle between normal screen and setup
menu tree.
Leave parameter, parameter-group or leave
parameter unsaved.
Toggle Operating mode between
Manual
and
Auto
.
Starts motor in
Auto
mode if Run signal active.
Starts motor in
Manual
mode.
Stops motor in all modes.
NOTE: A bus master may start motor at any time
Increase parameter when changing.
Moves between parameter-groups or parameters.
Decrease parameter when changing.
Moves between parameter-groups or parameters.
Motor Ramp
Run Control Freq.
Speed PI-reg Output Comm. Status Temp. Display Count. Version Error
P-Nom
Accel
Time
Phase
order
Control
mode
Operate
mode
Operate
mode
Operate
mode
Relay 1
Mode
RS485
bustype
U-rms
Motor
temp
Display
par.1
Operate
time
CoProc
version
Error-log
U-Nom
Decel
Time
Stop
mode
Auto-
start
FixFrq1 FixSpd1 FixReg1
Relay 1
Freq
RS485
addr
I-rms
Power
module
Display
par.2
Run
time
DSP
version
Restart
Delay
f-Nom
Ramp
Brkpoint
Energy
save
A.input
1 type
FixFrq2 FixSpd2 FixReg2
Relay 2
Mode
RS485
baud
P-out
COP
temp
Display
par.3
Brake
time
GUI
version
Reset
Time
N-Nom
Alt.
Accel
Pwr On
delay
A.input
2 type
FixFrq3 FixSpd3 FixReg3
Relay 2
Freq
RS485
char
PF
Heat
sink 1
Bklight
level
Cur.lim
time
Prod
date
AC Fail
I-Nom
Alt.
Decel
Run
delay
D.input
config
FixFrq4 FixSpd4 FixReg4
Aout 1
Mode
RS485
timeout
DC Link
Heat
sink 2
Bklight
timeout
DC low
time
Serial
number
Temp Hi
cos
Stop
delay
FixFrq5
FixSpd5
FixReg5
Aout 1
Max
RS485
autostop
Brake
chop
Heat
sink 3
Menu
readonly
Start
count
PTC
Temp
Tuning
DC
brake
FixFrq6
FixSpd6
FixReg6
Aout 2
Mode
RS485
failsafe
Stator
freq.
Heat
sink 4
Alarm
count
Over
load
R-stator
Kp
speed
FixFrq7
FixSpd7
FixReg7
Aout 2
Max
USB
bustype
Rotor
freq.
Fan 1
volt
Output
Energy
Ain
Fail
R-rotor
Ti
speed
A.input
min freq
A.input
min rpm
Setpoint
min
Analog
1 out
USB
addr
Control
freq.
Fan 2
volt
Total
Energy
DC
Low
L-main
Sleep
freq.
A.input
max freq
A.input
max rpm
Setpoint
max
Analog
2 out
USB
timeout
Rotor
speed
Fan 3
volt
DC
High
Sigma
Bypass
freq.
Actual
min
USB
autostop
Control
speed
Fan 4
volt
GND
Fail
I-magn
Bypass
bandw.
Actual
max
ABCC
interface
Actual
Torque
EXT
24V
Short
Circuit
I-limit
Boost
time
Setp
min limit
ABCC
bustype
Control
Torque
USB
5V
Imagn
Low
Pole
Count
Boost
level
Setp
max limit
ABCC
addr
Actual
PI-reg
Current
Low
T-nom
Reg
sign
ABCC
timeout
Setpoint
Pi-reg
Current
High
Tuned
status
Reg
Kp
ABCC
autostop
Ain 1 V
Current
Limit
Reg
Ti
Auto
reset
Ain1
mA
Run
Fail
Min
freq
Ain
2
V
Max
freq
Ain2
mA
Unit
Keybrd.
Off
limit
Terminal
On
limit
3006468-2022-04