Frequency Tests
MaxTester Copper Test
189
WB Attenuation
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4.
Press
to confirm the value.
WB Attenuation Result Details
The
Results Details
read-only page displays the
Cable
Length
,
Elapsed Time
, pass/fail status, and
WB
Attenuation
test results in graphical format.
Test Group
is the overall test group of the
selected saved results file, for example
Frequency
Tests
.
Test Identification
is the test type of the group, for
example
WB Attenuation
.
Test Mode
is the mode of test, for example
Attenuation
.
Cable Setup
button opens a new page displaying
the cable parameters of the test. Use the left/right arrows to select the
button and press