Configure Tests for DSL/IP Triple-Play Verification
158
AXS-200/635
Configure DSL/IP Tests
IPTV Analysis
The
IPTV Analysis
tab allows you to configure the unit for video testing.
The parameters are the following:
³
Join Multicast Address
is the
multicast address of the channel
that is automatically requested to
join when running the video
analysis during the auto test.
³
Monitoring Interval
is a list of
time interval values -
8
,
16
,
32
, or
64 min
- to set the length of time
for which data is plotted on a graph.
³
Test Thresholds
allow you to set critical quality of service (QoS)
values for delivering IPTV over DSL.
³
Max Packet Jitter (ms)
is a value in accordance with the network
characteristics, ranging from 0 through 99 milliseconds, to be used
as the pass or fail criteria for QoS.
³
Max Lost Packet Ratio (%)
is a percentage of the total packet rate,
ranging from 0 through 10.00, to use as pass/fail criteria for QoS.
³
Max ZAP Time(ms)
is the time in milliseconds, ranging from
0 through 999, required for a channel change and to be considered
when evaluating IPTV QoS.
³
MAX PCR Jitter (ms)
is the short-term variation in milliseconds,
ranging from 0 through 999, of the arrival of the PCR (program
clock reference) information at the video decoder.
³
Max MDI:DF (ms)
is the media delivery index (MDI) to delay factor
(DF) in milliseconds, ranging from 0 through 999.
³
Max MDI:MLR (packs/s)
is the media delivery index (MDI) to
media loss rate (MLR) in packets lost per second, ranging from
0 through 999.
Содержание AXS-200/635
Страница 1: ...User Guide Copper VDSL2 ADSL2 and IP Triple Play Test Set AXS 200 635...
Страница 8: ......
Страница 16: ......
Страница 32: ......
Страница 70: ......
Страница 86: ......
Страница 96: ......
Страница 110: ......
Страница 138: ......
Страница 244: ......
Страница 250: ......
Страница 260: ......