background image

User Guide

 Copper, VDSL2, ADSL2+, and IP

Triple-Play Test Set

AXS-200/635

Содержание AXS-200/635

Страница 1: ...User Guide Copper VDSL2 ADSL2 and IP Triple Play Test Set AXS 200 635...

Страница 2: ...ed by EXFO for its use nor for any infringements of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent rights of E...

Страница 3: ...tarted with Copper Qualification Tests 9 POTS Dialing 9 Regional Settings 12 Saving Results 19 Reading Saved Results 22 3 Auto CQ Video DSL Rate Prediction 25 CQ Auto Test 25 Configuring CQ Auto Tests...

Страница 4: ...ne RX 104 Send Tone TX 105 PSD Noise 106 Spectral Detective Test 110 Impulse Noise Test 113 Impulse Noise Histogram 115 Attenuation Test 118 Longitudinal Balance 120 Data Rate Prediction 122 9 Getting...

Страница 5: ...234 16 Maintenance 237 General Maintenance 237 Battery Charging and Replacing 237 Recycling and Disposal Applies to European Union Only 238 17 Troubleshooting 239 Solving Common Problems 239 Contactin...

Страница 6: ...e EMC Directive in the European Union The EN61326 standard prescribes both emission and immunity requirements for laboratory measurement and control equipment This unit has undergone extensive testing...

Страница 7: ...Declared EN 61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements EN 61326 1 2006 Electrical Equipment for Measurement Contr...

Страница 8: ......

Страница 9: ...delivers advanced IPTV measurements packet jitter packet loss PCR jitter MDI PID viewer and IGMP zap time both in Terminate stand alone and Through mode operation The AXS 200 635 also monitors reside...

Страница 10: ...Applications The AXS 200 635 allows you to test outside the customer premises over VDSL2 ADSL1 2 2 or inside over Ethernet Both modes allow you to use the Copper VDSL2 ADSL2 and IP Triple Play Test Se...

Страница 11: ...635 device Note When connecting a DSL cable to the WAN port use the RJ 45 plug end of the 26AWG cable provided with the unit There is a 1500V maximum transient voltage on telecom ports Basic insulatio...

Страница 12: ...D Red indicates that a voltage is detected on the line This is normal if the voice switch is connected to the circuit under test If the circuit is open foreign voltage is present either DC with batter...

Страница 13: ...access over existing copper cables The VDSL2 standard increases the spectrum allocation up to 30 MHz for even higher performance than its predecessor VDSL1 and allows speeds up to 100 Mbps symmetrical...

Страница 14: ...ss Most manual tests automatically run when they are selected from the menu The rotating hour glass in the title bar indicates when a test is running Note The unit checks for an active circuit at the...

Страница 15: ...eath or serious injury Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate in...

Страница 16: ......

Страница 17: ...ance and troubleshooting of copper cables To access copper qualification tests 1 From the Home pane use the up down arrow keys to highlight Copper Qualification Tests then press 2 From the Copper Qual...

Страница 18: ...wish to dial You can add this number to the Phone Book by pressing the Add to Phone Book button Dial button is enabled whether or not there is a number present in the NumbertoDial edit box If a numbe...

Страница 19: ...and numbers Names can be up to 30 characters long and numbers up to 32 digits Last Dialed lists up to 30 last dialed numbers Redial button dials a selected phone number from the Last Dialed list Icon...

Страница 20: ...s described below Distance Units are the units of measurement for distances in FEET or METER Cable Gauge is the gauge system for measuring wire sizes in AWG American Wire Gauge units or mm metric wire...

Страница 21: ...current profile Enter Profile Name is the new name of the profile To save modifications made to a CustomProfile 1 Select Save as New Profile and create and save a new CustomProfile name in the current...

Страница 22: ...ion to AIRCORE JELLY PULP 5 PR or 2 PR influences the cable capacitance per length automatically updating the Cap T R GND field Capacitance T R nF km or nF mi allows you to specify a value for the cap...

Страница 23: ...lue OR 4 Press the left arrow key to erase the existing value and then use the alphanumeric keypad to enter a value To cancel the entry press 5 Press to accept the value To reset default cable values...

Страница 24: ...the ITU International Telecommunications or ANSI American National Standards Institute standard Temperature allows you to specify the units of measurement for temperature in F Fahrenheit or C Celsius...

Страница 25: ...on will be disabled The phone book has 3 predefined entries Milliwatt Line Drop Battery and Quiet Line These entries can be edited but not removed To select a name number from the current list 1 Press...

Страница 26: ...hone book Number is the phone number maximum 32 digits including and comma Cancel button returns you to the phone book screen without saving any changes Update button stores the Name and Number entere...

Страница 27: ...L report Each entry on the pane is described as follows Save as Type lists the following formats to save your test results AXS200 format is a binary file format with ext dat This format can be opened...

Страница 28: ...ll be prompted to overwrite the existing file Report Header is where you can enter any comment The initial value is the current test followed by the date and time stamp Report s File Name is where you...

Страница 29: ...Press the left right and up down arrow keys to highlight the desired parameter 2 Press to display the list or select the value 3 Press the up down arrow key to highlight the desired value OR 4 Press...

Страница 30: ...Tests pane and pressing Read Saved Results The Read Saved Results tab allows you to select a test type and view the results of all the files previously saved Select Test Type provides a list of all th...

Страница 31: ...ance WB Data Rate Prediction Rect L Detection Resistive Balance To open previously saved test results 1 Press to open the list 2 In the list press the up down arrows to select the test type 3 Press to...

Страница 32: ......

Страница 33: ...stored threshold values to provide pass or fail results The results are displayed in both text and graphical format The following tests can be included in the CQ auto test function AC DC voltage and c...

Страница 34: ...List 1 The Test List 1 tab allows you to select the types of tests to include in the auto test function The following tests are available AC DC Voltage detects AC RMS and DC voltages in the line Togg...

Страница 35: ...terference has on the circuit under test Toggle between Enable and Disable VF Longitudinal Balance is very useful in identifying loops that will suffer from crosstalk Toggle between Enable and Disable...

Страница 36: ...bled the other is automatically disabled WB Longitudinal Balance verifies that the wideband longitudinal balance ratios comply with applicable standards PSD Noise measures power spectral density noise...

Страница 37: ...the available choices are AUTO 0 32 mm 0 40 mm 0 50 mm 0 60 mm 0 80 mm 0 90 mm or 1 20 mm Temperature specifies the temperature of the cable under test in either F Fahrenheit or C Celsius units Isolat...

Страница 38: ...ce when the cable is active or terminated by other external equipment For normal test termination select TERMINATED otherwise select BRIDGING Imp Noise Filter defines the type of impulse noise filteri...

Страница 39: ...ess the up down arrow keys to highlight the desired parameter 2 Press to display the list or select the value 3 Press the up down arrow keys to highlight the desired value OR 4 Press the left arrow ke...

Страница 40: ...requency bands in excess of 2 2 MHz are only displayed if VDSL2 is enabled in the software options WB Termination defines if the unit uses normal test impedance termination or high bridging impedance...

Страница 41: ...ress the up down arrow keys to highlight the desired parameter 2 Press to display the list or select the value 3 Press the up down arrow key to highlight the desired value OR 4 Press the left arrow ke...

Страница 42: ...30 Max DC Voltage T R V defines the maximum DC threshold voltage for the T R leg of the circuit Specify a value between 1 and 400 Max DC Voltage to GND V defines the maximum DC threshold voltage to gr...

Страница 43: ...CQ Auto Tests To set a threshold value 1 Press the up down arrow keys to highlight the desired parameter 2 Press to select the value 3 Press the left arrow key to erase the existing value and then use...

Страница 44: ...x VF Power Influence defines the maximum threshold power influence level on the circuit Specify a value between 90 and 20 dBm if the ITU standard is used Specify a value between 0 and 110 dBrnC if the...

Страница 45: ...CQ Auto Test pane tabs To run auto tests and view results 1 From the CQ Auto Test pane use the up down arrow keys to highlight Run Test and press 2 Press the F1 F2 or F3 key to view the various tabs T...

Страница 46: ...ital multimeter DMM test Isolation The Isolation tab displays the measured Resistance values from the isolation test Load Coil The Load Coil tab displays the number of load coils in the line and measu...

Страница 47: ...sts The VF Tests tab displays the measured values and PASS or FAIL status of the voice frequency tests VF Impulse Noise The VF Impulse Noise tab displays the measured values from the voice frequency i...

Страница 48: ...In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press to display a list of...

Страница 49: ...the box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press to disp...

Страница 50: ...ncrease the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press to display a list of zoom functions 2...

Страница 51: ...est TDR first attempts to find the length of the circuit and then searches all ranges from shortest to longest for significant events Upon completion the test selects the nearest major event sets the...

Страница 52: ...by the blue color of data above cursor 3 Press the up arrow key to select the red marker 4 Press the left right arrow keys to position the marker 5 The difference between the cursor and marker is con...

Страница 53: ...nd Video DSL rate Based on current loop conditions and user defined technology the video DSL rate prediction test shows you how many streams of standard broadcast SB and high definition HD IPTV video...

Страница 54: ...ore running the test ranging from 0 to 24 Mbps Default values are 8 Mbps for HD and 1 Mbps for SD Non Video Data Rate Mbps is a data rate of non video data typically used by high speed internet and Vo...

Страница 55: ...Target SNR is the desired signal to noise ratio ranging from 0 to 31 dB Default value is 6 dB To set parameter values 1 Press the up down or left right arrow keys to highlight the desired parameter 2...

Страница 56: ...sistance MOhm defines the minimum resistance ranging from 0 5 to 100 Default value is 3 6 Max Cap Balance defines the percentage maximum capacitance balance ranging from 0 to 20 Default value is 6 Min...

Страница 57: ...select TERMINATED otherwise select BRIDGING Termination Impedance defines the impedance of the dummy load connected to the line Select one of the following 100 or 135 Ohm Noise Filter defines the leve...

Страница 58: ...down arrow keys to highlight the desired parameter 2 Press to display the list or select the value 3 Press the up down arrow keys to highlight the desired value OR 4 Press the left arrow key to erase...

Страница 59: ...nce the tests are completed highlight the Details button from the Test Summary pane and press to view the results 3 Press the F1 F2 or F3 key to view the various tabs To view any available additional...

Страница 60: ...gain the pass indicator is displayed only if the analyzed number of HD streams matches the number set on the Configuration tab Otherwise the status is fail SD Streams is the number of standard definit...

Страница 61: ...is the High Def HD and Std Def SD stream rate before running the test ranging from 0 to 24 Mbps Default values are 8 Mbps for HD and 1 Mbps for SD Technology lists the following values ADSL2 ADSL2 or...

Страница 62: ...to highlight the desired parameter 2 Press to display the list or select the value 3 Press the up down arrow keys to highlight the desired value OR 4 Press the left arrow key to erase the existing val...

Страница 63: ...yed in the box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to...

Страница 64: ...ted function is displayed in the box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To z...

Страница 65: ...e box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a...

Страница 66: ...e and attenuation Configurable parameters include Annex lists the modes of available ADSL Annexes from the ITU standards A is ADSL service functioning over POTS B activates the ADSL functionality over...

Страница 67: ...p and re evaluate the rates To re set parameters to view different results 1 Press the up down or left right arrow keys to highlight the desired parameter 2 Press to display the list or select the val...

Страница 68: ...to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press to display a list of zoom functio...

Страница 69: ...r the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press the up or down arrow key to highlight the desired zoom function 2...

Страница 70: ......

Страница 71: ...he Thresholds tab allows you to set threshold values for the POTS auto test Each parameter is described below Min DC Current mA is a value ranging from 10 to 100 Default is 23 Max Loss dB is a value r...

Страница 72: ...s the left arrow key to erase the existing value and then use the alphanumeric keypad to enter a value To cancel the entry press 4 Press to accept the value 5 Select other parameters as required 6 Pre...

Страница 73: ...measure total electrical length with capacitance The DMM Tests menu includes the following tests DMM In service pair rectified loop and water detection Resistive balance DMM The DMM function allows y...

Страница 74: ...ailable choices are 1 MOhm 100 KOhm Connection defines the type of connection to be tested The available choices are Tip Ring Tip Gnd Ring Gnd To start stop the test 1 Press the up down arrow keys to...

Страница 75: ...Meter Each parameter is described below Cable Type defines the gauge of the cable in use If wire gauge is measured in AWG units the available choices are AUTO 19 AWG 22 AWG 24 AWG or 26 AWG For mm gau...

Страница 76: ...3 Press the up down arrow keys to highlight the desired value OR 4 Press the left right arrow keys to erase the existing value and then use the alphanumeric keypad to enter a value To cancel the entry...

Страница 77: ...nection to be tested The available choices are Tip Ring Tip Gnd Ring Gnd Note If the ANSI standard is used the tab name Isolation changes to Stress Leakage To start stop the test 1 Press the up down a...

Страница 78: ...defines the type of connection to be tested Cap bal thr nF is the capacitance balance threshold ranging from 0 1 to 20 nF If the measured capacitive balance in nF is greater than this threshold FAIL i...

Страница 79: ...arrow keys to highlight the desired value then press to select it 4 Select other parameters as required 5 Press to start stop the test Test results are displayed on the screen as they are completed Cu...

Страница 80: ...ated by other external equipment or TERMINATED if the unit uses normal test impedance termination Noise Filter is either PSOPHOMETRIC for ITU standard or C MESSAGE for ANSI standard To start stop the...

Страница 81: ...ongitudinal balance ratio for the twisted pair complies with applicable standards so as to reduce the effects of common mode voltage to ground The better the longitudinal balance of the cable pair the...

Страница 82: ...and the test will stop If an active circuit is detected a dialog box will be displayed to ask the you whether or not to proceed with the test In Service The In Service Pair Detection Test uses the bl...

Страница 83: ...The Rect L Detection tab displays a rectified loop state which often indicates the presence of corrosion on a circuit Rectified loops can disrupt balance and make the circuit unsuitable for Broadband...

Страница 84: ...d below Res Bal Thr ohm is the resistive balance threshold ranging from 0 1 to 20 ohms If the measured resistive balance in ohms is greater than this threshold the fail icon is displayed Otherwise the...

Страница 85: ...arrow key to erase the existing value and then use the alphanumeric keypad to enter a value To cancel the entry press 4 Press to accept the value 5 Select other parameters as required 6 Press to star...

Страница 86: ......

Страница 87: ...es of VF tests Receive tone RX Send tone TX Tracing tone VF noise Impulse noise Power influence Longitudinal balance Load coil detection To view VF test panes or tabs 1 From the VF Tests pane use the...

Страница 88: ...on either BRIDGING if the unit uses high bridging impedance when the cable is active or terminated by other external equipment or TERMINATED if the unit uses normal test impedance termination To start...

Страница 89: ...the tone level Specify a value between 20 and 10 Apply is used to confirm any changes to parameter values which can be changed while the test is running To start stop the test 1 Press the up down arr...

Страница 90: ...ntinuously until you stop the test Sinusoidal waveform is used to generate the 577 Hz signal Each parameter and button on the pane is described below Frequency Hz value is set to 577 Hz Level dBm is t...

Страница 91: ...ormal test termination select TERMINATED otherwise select BRIDGING Noise Filter defines the type of noise filtering to use If ANSI standard is used the available choices are NONE C MESSAGE C NOTCHED 3...

Страница 92: ...ormal test termination select TERMINATED otherwise select BRIDGING Noise Filter defines the type of noise filtering in use If ANSI standard is used the available choices are NONE C MESSAGE C NOTCHED o...

Страница 93: ...he desired parameter 2 Press to display the list or specify the value 3 Press the up down arrow keys to highlight the desired value OR 4 Press the left arrow key to erase the existing value and then u...

Страница 94: ...r Influence The Power Influence tab allows you to view the effects of interference from a 50 Hz or 60 Hz power line AC mains on the circuit under test The results of the power influence test are in gr...

Страница 95: ...reading To start stop the test Press to start stop the test Test results are displayed on the screen as they are completed Load Coil Detection The Load Coil detection test allows you to detect the pr...

Страница 96: ......

Страница 97: ...t then press 2 Press the F1 F2 or F3 key to view available tabs To view any available additional tabs use the function arrow keys on either side of the F1 and F3 keys TDR Test The time domain reflecto...

Страница 98: ...for most cables only change it when you know the correct VOP for the cable you are measuring An incorrect VOP will cause distance errors TDR The TDR test first attempts to find the length of the circu...

Страница 99: ...de and change to CursorMarker 2 Press the left right arrow keys to position the blue cursor indicated by the blue color of data above cursor 3 Press the up arrow key to select the red marker 4 Press t...

Страница 100: ...ter on the pane is described below Sect denotes the section number in the cable Select to enable or disable that section of the cable Cable Type defines the gauge of the cable in use If wire gauge is...

Страница 101: ...hlight the section icon then press 2 Use the left right arrow keys to highlight each parameter and press to open the list or select the value 3 Press the up down arrow key to highlight the desired val...

Страница 102: ...Diagram The Connection Diagram tab displays how to connect the cables to the unit The green lead is used as reference Continue button allows you to resume the test once the cables have been connected...

Страница 103: ...number in the cable Select to enable or disable that section of the cable Cable Type defines the gauge of the cable in use If wire gauge is measured in AWG units the available choices are AUTO 19 AWG...

Страница 104: ...tion icon then press 2 Use the left right arrow keys to highlight each parameter and press to open the list or select the value 3 Press the up down arrow key to highlight the desired value OR Press th...

Страница 105: ...parate Good Pair 4 wire Test Connection Diagram The Connection Diagram tab displays how to connect the cables to the unit Continue button allows you to resume the test once the cables have been connec...

Страница 106: ...est is only available if LoopMapper is enabled in the software options Test Setup The Test Setup tab allows you to configure parameters for the Loop Mapper test Define the Cable Type by selecting the...

Страница 107: ...Loop Mapper test TDR first attempts to find the length of the circuit and then searches all ranges from shortest to longest for significant events Upon completion the test selects the nearest major e...

Страница 108: ...of data above cursor 3 Press the up arrow key to select the red marker 4 Press the left right arrow keys to position the marker 5 The difference between the cursor and marker is continuously updated...

Страница 109: ...llows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a list of zoom f...

Страница 110: ......

Страница 111: ...l detective Impulse noise Impulse noise histogram Attenuation Longitudinal balance Data rate prediction Note Tests above 2 2 MHz are only available if VDSL2WB option is installed To view the wideband...

Страница 112: ...ther external equipment For normal test termination select TERMINATED otherwise select BRIDGING Termination Impedance defines the impedance of the dummy load connected to the line Select either 100 Oh...

Страница 113: ...the dummy load connected to the line Select either 100 or 135 Ohms Apply is used to confirm any changes to parameter values To start stop test 1 Press the up down arrow keys to highlight the desired t...

Страница 114: ...cess of 2 2 MHz are only displayed if VDSL2WB is enabled in the software options Termination defines if the unit uses normal test impedance termination or high bridging impedance when the cable is act...

Страница 115: ...t Set 107 PSD Noise To start stop the test 1 Press the up down arrow keys to highlight the desired test parameter 2 Press to open the list 3 Press the up down arrow keys to highlight the desired value...

Страница 116: ...zoom function Horizontal Zoom or Vertical Zoom The selected function is displayed in the box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to red...

Страница 117: ...ht the desired zoom function 3 Press to select the zoom function 4 Use the left right arrow key to highlight the Zoom In or Zoom Out button as required then press 5 The graphical display zooms in or o...

Страница 118: ...tab allows you to configure parameters for the wideband spectral detective test Each parameter on the pane is described below Bandwidth specifies the frequency range for the test Select 2 2 MHz 12 MHz...

Страница 119: ...11 Spectral Detective Test To start stop the test 1 Press the up down arrow keys to highlight the desired test parameter 2 Press to open the list 3 Press the up down arrow keys to highlight the desire...

Страница 120: ...o increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a list of zoom functions 2...

Страница 121: ...uipment For normal test termination select TERMINATED otherwise select BRIDGING Termination Impedance defines the impedance of the dummy load connected to the line Select one of the following 100 or 1...

Страница 122: ...n arrow keys to highlight the desired value OR 4 Press the left right arrow keys to erase the existing value and then use the alphanumeric keypad to enter a value To cancel the entry press 5 Press to...

Страница 123: ...or high bridging impedance when the cable is active or terminated by other external equipment For normal test termination select TERMINATED otherwise select BRIDGING Termination Impedance defines the...

Страница 124: ...To start stop the test 1 Press the up down arrow keys to highlight the desired test parameter 2 Press to open the list or specify a value 3 Press the up down arrow keys to highlight the desired value...

Страница 125: ...ncrease the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Use the left or right arrow key to highlight...

Страница 126: ...up tab allows you to configure parameters for the wideband attenuation test Select the Bandwidth of the frequency range for the test 2 2 12 17 or 30 MHz Note Frequency bands in excess of 2 2 MHz are o...

Страница 127: ...increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a list of zoom functions 2 P...

Страница 128: ...ngitudinal balance test Each parameter on the pane is described below Bandwidth specifies the frequency range for the test Select 2 2 MHz 12 MHz 17 MHz or 30 MHz Note Frequency bands in excess of 2 2...

Страница 129: ...you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a list of zoom functi...

Страница 130: ...P test displays the calculated downstream and upstream rates Each parameter on the pane is described below Annex defines the modes of available ADSL Annexes from the ITU standards A is ADSL service fu...

Страница 131: ...31 dB Default value is 6 dB Recalculate button allows you to change the setup and re evaluate the rates To re set parameters to view different results 1 Press the up down or left right arrow keys to...

Страница 132: ...am data rate M allows increased upload speeds from 1 Mbps to 3 5 Mbps Available only for ADSL2 and ADSL2 Technology lists the following values ADSL ADSL2 or ADSL2 If Annex L is previously selected ADS...

Страница 133: ...d parameter 2 Press to display the list or select the value 3 Press the up down arrow keys to highlight the desired value OR 4 Press the left arrow key to erase the existing value and then use the alp...

Страница 134: ...oom The selected function is displayed in the box Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom...

Страница 135: ...ease the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in out 1 Press to display a list of zoom functions 2 Press...

Страница 136: ...m for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press to display a list of zoom functions 2 Press the up down arrow...

Страница 137: ...Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press the up or down arrow key to highlight the desired zoom function 2 Press to select the zoom func...

Страница 138: ......

Страница 139: ...and loss PCR jitter MDI PID viewer and IGMP zap time and also supports higher layer testing such as ping traceroute and Web download speed DSL IP Tests VDSL2 ADSL2 and Ethernet tests include the Auto...

Страница 140: ...ad Saved Result allows you to view the Read Results page Read Saved Results The Read Results pane tab allows you to select a test type and view the results of all the files previously saved Types list...

Страница 141: ...configure the connection parameters during DSL IP tests 1 From the DSL IP Tests pane use the up down arrows to select the Connection Setup entry 2 Press to confirm the selection To view the available...

Страница 142: ...t LineMode is Ethernet and AccessMode is Bridged Profile Name is a list of all available profile files in the current directory with the first entry being Default Once you open the selected profile it...

Страница 143: ...ged Routed BrgdEthernet DHCP Routed BrgdEthernet Static Routed PPPoE Routed PPPoA Routed IPoA If Line Mode is set to VDSL2 the listed values are Bridged Routed BrgdEthernet DHCP Routed BrgdEthernet St...

Страница 144: ...ile from the new profile file At power up all settings are read from the last current profile Custom Profile is the new name of the profile To save modifications made to a CustomProfile 1 Select Save...

Страница 145: ...he LineMode selection is ADSL2 the available parameters are the following Annex defines the modes of available ADSL Annexes from the ITU standards Annex A is ADSL service functioning over POTS Annex B...

Страница 146: ...s set to either 100 or 10 Mbps To select the line parameters to configure 1 From the Connection Setup pane press the left right function arrows until the Line Params tab is displayed 2 Press the F1 F2...

Страница 147: ...C also known as LLC SNAP logical link control sub network address protocol or VC MUX virtual channel multiplex VLAN Support enables the unit to analyze and pass WAN tagged ethernet frames through the...

Страница 148: ...unction arrows until the WAN Access tab is displayed 2 Press the F1 F2 or F3 key located just below the tab to select it 3 Press the up down arrows to select the desired parameter 4 Press to open the...

Страница 149: ...MAC Address is the internal MAC address of the unit either AXS200 or User Defined MAC Address is a specific MAC address maximum 17 characters if you select User Defined for the previous parameter When...

Страница 150: ...available parameters are the following Obtain IP is either Dynamic where the access concentrator or broadband remote access server assigns a temporary IP address to the unit or Static where you enter...

Страница 151: ...able enter 0 0 0 0 Note WAN IP setup is not required when Access Mode is set to Bridged The line encapsulation setting defines the parameters required To select the WAN IP parameters to configure 1 Fr...

Страница 152: ...LAN Tagging enables the unit to recognize frames with a specified PVID This entry is disabled if VLAN Support is set to Disable on the WAN Access pane LAN DHCP Server enables the dynamic host configur...

Страница 153: ...e left right function arrows until the LAN Setup tab is displayed 2 Press the F1 F2 or F3 key located just below the tab to select it 3 Press the up down arrows to select the desired parameter 4 Press...

Страница 154: ...asured values must be greater than these limits For DownStream If LineMode is set to ADSL2 valid values are 0 through 25000 with a default value of 100 If LineMode is set to VDSL2 valid values are 0 t...

Страница 155: ...igure 1 From the Connection Setup pane press the left right function arrows until the Thresholds tab is displayed 2 Press the F1 F2 or F3 key located just below the tab to select it 3 Press the up dow...

Страница 156: ...lue of 0 When this entry is set to 0 all VPI and VCI entries are unavailable VPI is the virtual path identifier VPI ranging from 0 through 255 for the downstream channel VCI is the virtual circuit ide...

Страница 157: ...rform various tests for the applications to be verified These tests are accessible through the different pane tabs To access the configure tests during a DSL IP test 1 From the DSL IP Tests pane use t...

Страница 158: ...st of previously saved profiles with the first entry being Default Save to File allows you to save test parameters to a default profile or a new custom file name To select test configuration parameter...

Страница 159: ...o When this entry is enabled all other test choice entries on the Auto Test pane are automatically disabled Data Analysis runs an auto test for data by enabling the unit to act as a modem allowing you...

Страница 160: ...cally disabled CPE HTTP Speed measures the speed of downloading Web pages in auto test When this entry is enabled IPTV Data and VoIP analyses are automatically disabled CPE FTP Speed measures the spee...

Страница 161: ...al path identifier VPI of the ATM connection VCI is a value ranging from 32 through 65535 for the virtual circuit identifier VCI of the ATM connection Cell Type initiates either End to End or Segment...

Страница 162: ...he default value is 32 Total Pings is the total number of ping packets to send out from 1 through 99 The default value is 3 Timeout is the time in seconds from 1 through 15 that the unit will wait for...

Страница 163: ...rameters are the following Address Format lists the address either as a URL or IP Address Destination Address is the destination IP address Max hops is a value from 1 through 99 specifying the maximum...

Страница 164: ...which is the destination IP address or Web site URL to be downloaded depending on the test selected from the http server To select the download parameter to configure 1 Press the up down arrows to se...

Страница 165: ...ault value is anonymous Password is your user password maximum 36 characters Download File Name is the filename requested for downloading maximum 128 characters left blank if no download test is requi...

Страница 166: ...a value in accordance with the network characteristics ranging from 0 through 99 milliseconds to be used as the pass or fail criteria for QoS Max Lost Packet Ratio is a percentage of the total packet...

Страница 167: ...select the IPTV analysis parameters to configure 1 Press the up down arrows to select the desired parameter 2 Press to open the list or modify the parameter 3 In the list press the up down arrows to s...

Страница 168: ...s will be evaluated Max PCR Jitter ms is a value in accordance with the characteristics of the network ranging from 0 through 200 to be used as the pass or fail criteria for the quality of service QoS...

Страница 169: ...ows you to select the Monitoring Interval which is a list of time interval values 8 16 32 or 64 min to set the length of time for which data is plotted on a graph To select the monitoring interval 1 P...

Страница 170: ...assigns a temporary IP address to the set top box or Static where you enter the IP address of the set top box STB Vendor ID is the name of the set top box maximum 80 characters This entry is unavaila...

Страница 171: ...and Details of a series of CPE test results The available test results are the following Line Status displays either Connected or Disconnected for the particular line connection under test WAN Status...

Страница 172: ...iew the conditions of the line under test which was configured in the connection setup The available test results are the following Line Status displays Showtime when the unit and the DSLAM have succe...

Страница 173: ...t rate Max BitRate presented as a percentage A high value could mean that the link is nearing its maximum capabilities while a low value could mean the link is being under utilized sometimes intention...

Страница 174: ...it power INP is the level of impulse noise protection Interl Depth is interleave depth which defines the number of bits or bytes in each block of data Interl Delay is interleave delay which defines th...

Страница 175: ...es records the number of active non idle PTM ATM cells or frames transmitted on a channel PTMCRC is the number of cyclical redundancy check CRC errors of the PTM PTMCV is the number of constant veloci...

Страница 176: ...across all active sub channels as an amount of increased noise relative to the measured noise power that the system would be able to tolerate to maintain a bit error rate of 10 7 LoopAttn is the curre...

Страница 177: ...by 4 325 kHz Zoom In allows you to increase the level of zoom for the selected zoom function Zoom Out allows you to reduce the level of zoom for the selected zoom function To zoom in or out 1 Press th...

Страница 178: ...network access either Bridged or Routed mode Status displays either Connected or Disconnected for the particular line connection under test Encapsulat is the encapsulation method used by the network...

Страница 179: ...ection Assigned IP is the IP address information assigned to the unit that is actively connected to your network or the internet at the time of login Gateway is the IP address of the default gateway S...

Страница 180: ...stination being pinged PckSize is the number of bytes sent in one packet ranging from 32 through 1200 default is 32 bytes Pings display the total number of ping requests to be sent Ping Status is the...

Страница 181: ...an IP packet being sent to a specified IP destination and the path and time taken to do so The available test results are the following Dest Addr is the destination IP or URL address Max hops specifie...

Страница 182: ...ing DwnlAddress is the destination IP address or Web site that was downloaded Download button starts the HTTP speed test displaying the progress below Resolving Address is the address of the DwnlAddre...

Страница 183: ...oad File is the name of the file downloaded to the FTP server The Download button starts downloading the file entered here Upload File is the name of the file uploaded to the FTP server The file size...

Страница 184: ...Master or Client for the selected device Link State is the Up to Down or vice versa routing protocol of the network link for the selected device Sync State is the sync status of the selected device SW...

Страница 185: ...nt Rx Packets is the number of packets received Tx Bytes is the count of bytes sent Rx Bytes is the count of bytes received Rx CRC Packets is a count of cyclical redundancy check CRC errors received T...

Страница 186: ...ction value results of the VPI virtual path identifier and VCI virtual circuit identifier and the PTI payload type identifier which is either End To End or Segment If the unit is not connected to the...

Страница 187: ...lts Textual results must be formatted as a comma separated values table for easy importation to Excel Results are saved to a USB gif stands for graphics interchange format and is one of the most commo...

Страница 188: ...ting file The default extension is html The default name is generated from the current time Save Report to USB button saves the results to an HTML report If a USB memory stick is not inserted the foll...

Страница 189: ...l the tests configured for the DSL and Ethernet layers over which the IPTV service is being delivered If a measured value is out of the threshold range configured for the IPTV analysis setup the Test...

Страница 190: ...the amount of time the video must be delayed in the virtual buffer due to cumulative IP packet jitter and IP packetization MDI MLR is the media delivery index MDI media loss rate MLR which monitors th...

Страница 191: ...otiated applicable data rates for the particular connection under test During negotiation with the DSLAM the value changes from Booting DecompressImage StartProgram LoadModules Idle Activate Ready Han...

Страница 192: ...resented as a percentage A high value could mean that the link is nearing its maximum capabilities while a low value could mean the link is being under utilized sometimes intentionally verify your loc...

Страница 193: ...absolute transmit power INP is the level of impulse noise protection Interl Depth is interleave depth which defines the number of bits or bytes in each block of data Interl Delay is interleave delay w...

Страница 194: ...umber of active non idle PTM ATM cells or frames transmitted on a channel PTMCRC is the number of cyclical redundancy check CRC errors of the PTM PTMCV is the number of constant velocity CV errors of...

Страница 195: ...tio SNR margin across all active sub channels as an amount of increased noise relative to the measured noise power that the system would be able to tolerate to maintain a bit error rate of 10 7 LoopAt...

Страница 196: ...etwork access either Bridged or Routed mode Status displays either Connected or Disconnected for the particular line connection under test Encapsulat is the encapsulation method used by the network an...

Страница 197: ...tion Assigned IP is the IP address information assigned to the unit that is actively connected to your network or the internet at the time of login Gateway is the IP address of the default gateway Sub...

Страница 198: ...N The available information is as follows STB IP address is the IP address of the set top box STB connected to the LAN port STB MAC address is the MAC address of the STB connected to the LAN port Subn...

Страница 199: ...file transfer protocol mode sessions resulting from the video tests Down Stream Rate The DnStreamRate tab allows you to view the bit rates of different layers related to the IPTV service The availabl...

Страница 200: ...on FEC frames that have been rectified by the Reed Solomon error correction When in the fast setting the result will be 0 This parameter is useful for determining if a problem exists based on how many...

Страница 201: ...quest is the number of unsolicited IGMP joins issued by the STB or the user Leave Request is the number of IGMP leaves issued by the STB or the user Last Request displays the multicast addresses for J...

Страница 202: ...rt Status displays a message for the condition of the last RTSP Res Time is the response time in ms from video request to incoming video data StatCode displays the RTSP status codes defined as follows...

Страница 203: ...tood 452 Conference Not Found 453 Not Enough Bandwidth 454 Session Not Found 455 Method Not Valid in This State 456 Header Field Not Valid for Resource 457 Invalid Range 458 Parameter Is Read Only 459...

Страница 204: ...addresses and port numbers Stream IP is the multicast IP address assigned to a specific channel Type describes the video stream as RTSP video on demand VOD or live TV streaming over connection based...

Страница 205: ...a selected multicast IP address assigned to the specific video channel or Analyzed Stream The available test results are the following Max Recorded Jitter is the maximum jitter detected in ms Average...

Страница 206: ...The available test results are the following PCR Packets Rate is the number of received packets monitored over a one second period Average Jitter is the continuous running average of the jitter detec...

Страница 207: ...ckets Null packets are defined as having no data MDI is the media delivery index MDI or IP cumulative jitter and packet loss rate for the video stream DF Ave is the average delay factor DF or the aver...

Страница 208: ...ideo Audio and Program Association Map Table s content for each MPEG video Analyzed Stream The available statistical results are the following PID is a unique integer value or packet identifier PID th...

Страница 209: ...s Mode displays Master or Client for the selected device Link State is the Up to Down or vice versa routing protocol of the network link for the selected device Sync State is the sync status of the se...

Страница 210: ...the number of packets received Tx Bytes is the count of bytes sent Rx Bytes is the count of bytes received Rx CRC Packets is a count of cyclical redundancy check CRC errors received Tx Packets Dropped...

Страница 211: ...lts Textual results must be formatted as a comma separated values table for easy importation to Excel Results are saved to a USB gif stands for graphics interchange format and is one of the most commo...

Страница 212: ...ng file The default extension is html The default name is generated from the current time Save Report to USB button saves the results to an HTML report If a USB memory stick is not inserted the follow...

Страница 213: ...ts Test Summary The Test Summary tab allows you to view the PASS FAIL status and Details of the different tests If a measured value is out the thresholds configured in the data analysis setup or if th...

Страница 214: ...threshold range UpStream Rates displays whether the maximum attainable upstream bit rate that the circuit can handle is within the threshold range Details button shortcuts to the applicable tab which...

Страница 215: ...otiated applicable data rates for the particular connection under test During negotiation with the DSLAM the value changes from Booting DecompressImage StartProgram LoadModules Idle Activate Ready Han...

Страница 216: ...resented as a percentage A high value could mean that the link is nearing its maximum capabilities while a low value could mean the link is being under utilized sometimes intentionally verify your loc...

Страница 217: ...absolute transmit power INP is the level of impulse noise protection Interl Depth is interleave depth which defines the number of bits or bytes in each block of data Interl Delay is interleave delay w...

Страница 218: ...cells or frames received on a channel Transmit Bytes records the number of active non idle PTM ATM cells or frames transmitted on a channel DSL Counters lists the Local and Remote results for the fol...

Страница 219: ...tio SNR margin across all active sub channels as an amount of increased noise relative to the measured noise power that the system would be able to tolerate to maintain a bit error rate of 10 7 LoopAt...

Страница 220: ...etwork access either Bridged or Routed mode Status displays either Connected or Disconnected for the particular line connection under test Encapsulat is the encapsulation method used by the network an...

Страница 221: ...tion Assigned IP is the IP address information assigned to the unit that is actively connected to your network or the internet at the time of login Gateway is the IP address of the default gateway Sub...

Страница 222: ...of the network device connected to the LAN port LAN IP is the local network IP address of the unit LAN SubMask is the network address mask used to identify if the IP address is within the same local...

Страница 223: ...e local network devices The screen identifies the source IP address Client IP Address of the different requests as well as the amount of transmitted Download and received Upload information Protocols...

Страница 224: ...ps is the maximum downstream rate of the data stream for the connection Reset Statistics button sets all monitoring values to 0 Up Stream Rates The UpStream Rates tab allows you to view the maximum ac...

Страница 225: ...s Mode displays Master or Client for the selected device Link State is the Up to Down or vice versa routing protocol of the network link for the selected device Sync State is the sync status of the se...

Страница 226: ...the number of packets received Tx Bytes is the count of bytes sent Rx Bytes is the count of bytes received Rx CRC Packets is a count of cyclical redundancy check CRC errors received Tx Packets Dropped...

Страница 227: ...Textual results must be formatted as a comma separated values table for easy importation to Excel Results are saved to a USB gif stands for graphics interchange format and is one of the most common f...

Страница 228: ...ng file The default extension is html The default name is generated from the current time Save Report to USB button saves the results to an HTML report If a USB memory stick is not inserted the follow...

Страница 229: ...onfigured in the VoIP analysis setup or if the WAN LAN connection was not completed successfully the Summary pane will display a FAIL message The available test results are the following Line Status d...

Страница 230: ...w the conditions of the line under test which was configured in the connection setup The available test results are the following Line Status displays Showtime when the unit and the DSLAM have success...

Страница 231: ...it rate Max BitRate presented as a percentage A high value could mean that the link is nearing its maximum capabilities while a low value could mean the link is being under utilized sometimes intentio...

Страница 232: ...mit power INP is the level of impulse noise protection Interl Depth is interleave depth which defines the number of bits or bytes in each block of data Interl Delay is interleave delay which defines t...

Страница 233: ...ive non idle PTM ATM cells or frames received on a channel Transmit Bytes records the number of active non idle PTM ATM cells or frames transmitted on a channel DSL Counters lists the Local and Remote...

Страница 234: ...across all active sub channels as an amount of increased noise relative to the measured noise power that the system would be able to tolerate to maintain a bit error rate of 10 7 LoopAttn is the curr...

Страница 235: ...s PPPoE is point to point protocol over Ethernet PPPoA is point to point protocol over ATM Bridged Ether DHCP is also known as multi protocol encapsulation over ATM MPoA IPoA stands for classical inte...

Страница 236: ...s you to view the customer information configured for the local area network LAN The available information is as follows Client IP is the IP address of the network device connected to the LAN port Cli...

Страница 237: ...resulting from the voice tests It displays whether or not registration activity for the voice protocol is detected SIP Session Initiation Protocol is a signalling protocol used for establishing sessio...

Страница 238: ...ng Codec is the VoIP coder decoder in use as detected by the unit Received Packets display the total number of received VoIP packets Lost Packet is the total number of lost VoIP packets that were neve...

Страница 239: ...he call by displaying an estimate of the variance of the real time transport protocol RTP data packet inter arrival time The available test results are Jitter Average is the continuous running average...

Страница 240: ...Master or Client for the selected device Link State is the Up to Down or vice versa routing protocol of the network link for the selected device Sync State is the sync status of the selected device S...

Страница 241: ...sent Rx Packets is the number of packets received Tx Bytes is the count of bytes sent Rx Bytes is the count of bytes received Rx CRC Packets is a count of cyclical redundancy check CRC errors receive...

Страница 242: ...s must be formatted as a comma separated values table for easy importation to Excel Results are saved to a USB gif stands for graphics interchange format and is one of the most common file formats for...

Страница 243: ...overwrite the existing file The default extension is html The default name is generated from the current time Save Report to USB button saves the results to an HTML report If a USB memory stick is no...

Страница 244: ......

Страница 245: ...Avoid unnecessary shocks and vibrations If any liquids are spilled on or into the unit turn off the power immediately and let the unit dry completely Battery Charging and Replacing Charging the AXS 2...

Страница 246: ...European Union member state with legislation regarding Directive 2002 96 EC Except for reasons of safety or environmental benefit equipment manufactured by EXFO under its brand name is generally desig...

Страница 247: ...ompartment door Insert 2 batteries and replace battery compartment door The display is almost blank when you turn on the unit Brightness may need some adjustment Press to adjust brightness properly Ba...

Страница 248: ...upport visit the EXFO Web site at www exfo com To accelerate the process please have information such as the name and the serial number see the product identification label an example is shown below a...

Страница 249: ...when transporting the unit Transportation damage can occur from improper handling The following steps are recommended to minimize the possibility of damage Pack the unit in its original packing materi...

Страница 250: ......

Страница 251: ...fication of calibration during the warranty period and found to meet all published specifications EXFO will charge standard calibration fees THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED...

Страница 252: ...f its products at any time without incurring obligation to make any changes whatsoever on units purchased Accessories including but not limited to fuses pilot lamps batteries and universal interfaces...

Страница 253: ...defect and the conditions under which it was observed 5 Return the equipment prepaid to the address given to you by support personnel Be sure to write the RMA number on the shipping slip EXFO will re...

Страница 254: ...55 USA and Canada Tel 1 418 683 5498 Fax 1 418 683 9224 quebec service exfo com EXFO Europe Service Center Omega Enterprise Park Electron Way Chandlers Ford Hampshire S053 4SE ENGLAND Tel 44 2380 2468...

Страница 255: ...2 Ethernet 10 100 Supported video compression standards MPEG2 MPEG4 part 2 and 10 H 264 AVC WM9 Operation Terminate and Pass Through IPTV parameters functionality Video streaming channels detection I...

Страница 256: ...pings 1 to 99 Packet size 32 to 1500 bytes 32 is default Results Indicate packet size packets sent received minimum average maximum round trip times in milliseconds ms Traceroute Determines the path...

Страница 257: ...tion dB 1 to 6 in 1 dB steps Dead time ms 125 Filters None 3 kHz flat C message psophometric notched and D filter IEEE 743 1995 Counter Maximum 999 for each threshold Timer 1 minute to 24 hours defaul...

Страница 258: ...1 nF to 10 F 3 digits 2 1 digit Distance up to 30 000 m 100 000 ft DC current 0 to 110 mA 1 mA 2 1 digit AC current 0 to 77 mA 1 mA 2 1 digit SPECTRAL DETECTIVE Allows the AXS 200 635 to bridge high i...

Страница 259: ...battery state indication Test connections Five color banana connector for T R G T1 R1 RJ 45 for ADSL2 and Ethernet 10 100 WAN RJ 45 for Ethernet 10 100 LAN Differential voltage protection 125 VRMS or...

Страница 260: ......

Страница 261: ...mon parameters 29 test list 1 26 test list 2 28 thresholds 1 34 thresholds 2 36 VF test parameters 30 WB test parameters 32 configuring video DSL rate prediction configuration 46 impulse noise 49 thre...

Страница 262: ...el 240 impulse noise histogram test 115 impulse noise test 113 configuration 84 results 86 in service pair detection test 74 IPTV analysis results detected streams 196 downstream rates 191 DSL Params...

Страница 263: ...CPE tests 163 data analysis 205 IPTV test 181 read saved 22 132 save 19 VoIP tests 221 return merchandise authorization RMA 245 RFL 2 wire test configuration 92 connection diagram 94 result 94 RFL 4 w...

Страница 264: ...status 222 network activity 229 packets analysis 230 save result 234 statistics 225 summary 221 VDSL bands 226 WAN status 227 voltage test 66 W warranty certification 244 exclusions 244 general 243 l...

Страница 265: ...363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 SJ T11363 2006 Pa...

Страница 266: ...MARKING REQUIREMENTS Product Environmental protection use period years Logo This Exfo product EXFO 10 Batterya a a If applicable 5...

Страница 267: ...Swee Road 03 29 Manhattan House SINGAPORE 169876 Tel 65 6333 8241 Fax 65 6333 8242 EXFO CHINA No 88 Fuhua First Road Central Tower Room 801 Futian District Beijing New Century Hotel Office Tower Room...

Отзывы: