Exergen Temporal Scanner 2000C Скачать руководство пользователя страница 2

READ ALL INSTRUCTIONS BEFORE USING

When using the product, especially when children are present, basic
safety precautions should always be followed, including the following:

z

This product is intended for household use only.  For information
on thermometers for professional use, please see www.exergen.com, 
or call 617-923-9900.

z

Use this product only for its intended use as described in this manual.

z

Use of this product is not intended as a substitute for consultation with your 
physician.

z

Do not take temperature over scar tissue, open sores or abrasions.

z

Basic safety precautions should always be observed, especially 
when this product is used by, on or near children or invalids.

z

The operating environmental temperature range for this product 
is 60 to 104°F (15.5 to 40°C).

z

Always store this thermometer in a clean, dry place where it will not 
become excessively cold  (-4°F/-20°C), or hot (122°F/50°C).

z

The thermometer is not shockproof.  Do not drop it or expose it to 
electrical shocks.

z

This thermometer is not intended to be sterile.  Do not try to sterilize it.  
Follow the cleaning instructions as described in this manual.

z

Do not use this thermometer if it is not working properly, if it has been 
exposed to temperature extremes, damaged, been subject to electrical 
shocks or immersed in water.

z

There are no parts that you can service yourself except for the battery, 
which you should replace when low following the instructions in this 
manual.  For service, examination, repair, or adjustments, return your 
thermometer to Exergen.

z

Do not operate where aerosol spray products are being used or where 
oxygen is being administered.

z

Do not take temperatures with this thermometer near places that are 
very hot, such as fireplaces and stoves.

z

Do not use this thermometer outdoors.

z

Never drop or insert any object into any opening.

Important Safety Instructions

2

tat2000instrev6.qxd  2/6/2006  9:35 AM  Page 2

Содержание Temporal Scanner 2000C

Страница 1: ...w temporalscanner com for Educational Video Remove protective cap before using Reads arterial temperature which is a core temperature very close to rectal temperature See pg 9 Sensor should be clean S...

Страница 2: ...where it will not become excessively cold 4 F 20 C or hot 122 F 50 C z The thermometer is not shockproof Do not drop it or expose it to electrical shocks z This thermometer is not intended to be ster...

Страница 3: ...ng maximum ease of use with quick consistently accurate measurements Advanced patented technology measures temperatures with a gentle stroke across the forehead The TemporalScanner Thermometer has bee...

Страница 4: ...skin surface to provide access needed to take an accurate measurement It is easy to use because it is ideally located at the front portion of the forehead The TemporalScanner is easier and gentler to...

Страница 5: ...g Beep and LED flashing indicate a rise to a higher temperature similar to a radar detector Slow beeping indicates that the instrument is still scanning but not finding any higher temper atures z Reta...

Страница 6: ...g of the skin z An infant is frequently swaddled in blankets and clothing covering the neck area Unless visibly sweaty one measurement at the TA area is typically all that is required Should you feel...

Страница 7: ...elease the button and read the temperature Note Normally the artery behind the ear lobe does not provide a sufficiently accurate reading However this area is less affected by sweating than the fore he...

Страница 8: ...in contact with the skin until you reach the hairline You will hear a beeping and a red light will blink to indicate a measurement is taking place If perspiration is present continue to hold but ton...

Страница 9: ...ld be consulted in the following situations where fever is present vomiting diarrhea changes in appetite activity or breathing or with children who are irritable lethargic or unusually sleepy Normal T...

Страница 10: ...igher than oral temperature 6 Expect the Differences Arterial temperature measurement leads all other methods in identifying fever or falling of an elevated temperature and is unaffected by activities...

Страница 11: ...g for Baby and Young Child Birth to Age 5 American Academy of Pediatrics Bantam 1999 4 Keith R Powell M D Dr Noah Miller Chair of Pediatrics Children s Hospital Medical Center of Akron and Professor a...

Страница 12: ...ipe with a small cloth or swab moistened with alcohol z Hold upside down to prevent excess moisture from entering the sensor area It will not harm the sensor but if it becomes too wet you will be unab...

Страница 13: ...battery to measure correct temperature Replace battery Remove the battery compartment door by pushing down on the ridges with your thumb and pushing away as indicated Use both thumbs if necessary Ins...

Страница 14: ...e used The temperature of the thermometer is lower than 60 F 15 5 C Let instrument acclimatize for about 30 minutes in a warmer area in which it will be used EMI RFI like static on a radio protection...

Страница 15: ...readings Size 7 0 in x 1 75 in x 1 25 in 17 8 cm x 4 45 cm x 3 18 cm Weight 4 5 oz 130 grams incl batt Display Type High contrast LCD Construction Method Impact resistant casing hermetically sealed se...

Страница 16: ...imply call Exergen Corporation Customer Service 617 923 9900 for a Return Material Authorization number RMA Then send the product postage or shipping prepaid to Exergen in accordance with the instruct...

Отзывы: