background image

SSE232-IA  User’s Manual 

 

Exemys 

 

 

www.exemys.com 

Rev. 4 

Page28 

 

 

Table 

Table 

Table 

Table 15

15

15

15    ---- OUT command

 OUT command

 OUT command

 OUT command    

Command

Command

Command

Command    

Description

Description

Description

Description    

Answer

Answer

Answer

Answer    

OUTo:s<CR> 

Changes the status of the o output. 
o = 0..m-1 (“m” is the quantity of outputs available  
on each model). 
s = 0..1 Is the new status of output o. 

OUTo:s,OK<CR> 
The status of the output 
“o” has been changed. 
 
OUTo:s,ERROR<CR> 
The output is not 
available or not available 
on this model 

3.2.8.4

3.2.8.4

3.2.8.4

3.2.8.4

 

Automatic Digital 

Automatic Digital 

Automatic Digital 

Automatic Digital Input Report (DIR)

Input Report (DIR)

Input Report (DIR)

Input Report (DIR)    

In the Supervision and Control port, SSE232-IA provides a way to handle inputs events. SSE232-IA 
can report the status of all inputs when detecting a change in one of them. 
If the automatic digital input report option is enabled, SSE232-IA will inform the status of all the 
inputs when a client connects to the TCP Port 999 and every time a change in any of the available 
inputs is detected. 
This option can be enabled or disabled according to your needs. 
 
To enable or disable the automatic digital input report through the configuration Web page: 

 

Select “Network” from the menu, you will see the Network configuration page. 

 

Select the Digital Input Report Enabling from the combo box. 

 

Click on the “Send” button, so the SSE232-IA may take the changes. 

 

 
 
 
 
 
 
 
 
 

 
You may enable or disable this option from the configuration command console by executing the 
DIREPORT

DIREPORT

DIREPORT

DIREPORT command. 
 

Table 

Table 

Table 

Table 16

16

16

16    ---- DIREPORT command

 DIREPORT command

 DIREPORT command

 DIREPORT command    

Command

Command

Command

Command    

Description

Description

Description

Description    

DIREPORT:(E|D) 

Configures the option of Automatic Digital Inputs Report in the  
supervision and control mode. 
E = Enabled 
D = Disabled 

 

Содержание SSE232-IA

Страница 1: ...www exemys com Internet Enabling Solutions User s Manual SSE232 IA Serial Server ...

Страница 2: ...emys Products are in constant evolution to satisfy our customer needs For that reason the specifications and capabilities are subject to change without prior notice Updated information can be found at www exemys com Copyright Exemys 2006 All Rights Reserved Rev 4 ...

Страница 3: ..._________________ _________________________________________________ _________________ _________________ _________________ 12 12 12 12 2 4 1 Connection through a Hub or Switch 12 CONFIGURATION AND OPERATION 13 3 1 3 1 3 1 3 1 Getting Started Getting Started Getting Started Getting Started________________________________ ________________________________ ________________________________ _____________...

Страница 4: ...ommand ___________________________________________________________________ 20 Table 9 Configuration of serial ports___________________________________________________________ 22 Table 10 ARESET command _________________________________________________________________ 23 Table 11 Server Mode Channel Configuration____________________________________________________ 24 Table 12 Client Mode Channel Co...

Страница 5: ...ys www exemys com Rev 4 Pagev Figure 15 Assembly of the device on DIN rail ____________________________________________________ 36 Figure 16 Disassembling of the device _________________________________________________________ 36 ...

Страница 6: ...information on SSE232 IA configuration and operation is included 1 1 2 1 1 2 1 1 2 1 1 2 Conventions terms and acronyms Conventions terms and acronyms Conventions terms and acronyms Conventions terms and acronyms The acronyms used in this manual are listed in the following table Table Table Table Table 1 1 1 1 Acronyms Acronyms Acronyms Acronyms Acronym Description ARP Address Resolution Protocol ...

Страница 7: ... like alarm panels data acquisition systems PLCs or any other device with a serial interface SSE232 IA is the interface between the equipment with serial communication and the Ethernet network acting as a transparent converter and also providing digital inputs outputs that can be independently handled The amount of digital input outputs and the amount and type of ports supplied by SSE232 IA depend...

Страница 8: ...figuration ETHERNET ETHERNET ET HERNET Outputs Inputs RS 232 Serial Configuration Console TCP configuration Console I O Control Serial Device Serial Device Figure Figure Figure Figure 2 2 2 2 Example of Application Example of Application Example of Application Example of Application ...

Страница 9: ... wiring in the equipment as noted in the NEC Vin Vin Figure Figure Figure Figure 3 3 3 3 Power Input Connection scheme Power Input Connection scheme Power Input Connection scheme Power Input Connection scheme 2 2 I O Configuration The amount of inputs outputs supplied by SSE232 IA is indicated in the product code as shown in figure 1 Table Table Table Table 3 3 3 3 I O Configuration I O Configurat...

Страница 10: ...ng scheme In models SSE232 XX4C IA four I O terminals may be configured as Inputs or Outputs depending your needs This configuration is done in a hardwired manner changing the jumpers accordingly Figure 5 shows how to configure the jumpers for the 4 I O terminals To access this jumpers open the SSE232 IA case and pull out To configure a terminal as an output short circuit the jumper Out of that te...

Страница 11: ... 3 1 2 3 1 2 3 1 RS RS RS RS 232 Connection 232 Connection 232 Connection 232 Connection COM A is always found in all SSE232 IA models A cable can be used to connect RS 232 serial ports to a PC serial port as can be observed in figure 6 DB9 Hembra Rx 2 Tx 3 GND 5 TxA RxA GND PC SSE232 IA Figure Figure Figure Figure 6 6 6 6 Serial Cable scheme Serial Cable scheme Serial Cable scheme Serial Cable sc...

Страница 12: ...A to operate Generally it can be connected to a Hub or Switch or directly to a computer 2 4 1 2 4 1 2 4 1 2 4 1 Connection through a Hub or Switch Connection through a Hub or Switch Connection through a Hub or Switch Connection through a Hub or Switch A UTP network cable must be used to connect SSE232 IA to the Ethernet through a Hub or Switch Figure 8 shows how the UTP cable is wired when using a...

Страница 13: ...uration parameters may be modified at any time using any of the methods mentioned above 3 1 1 3 1 1 3 1 1 3 1 1 IP Address Configuration IP Address Configuration IP Address Configuration IP Address Configuration SSE232 IA default configuration IP is 0 0 0 0 so when turned on it will look for a DHCP server SSE232 IA tries to negotiate an IP address with a DHCP server for a maximum period of 10 seco...

Страница 14: ...XX In a Unix like OS the command to add an entry to the ARP table is as follows arp s 192 168 0 105 00 0B FA XX XX XX Send a ping to the IP address you added to the ARP table on the previous step by entering the following command ping 192 168 0 105 t The t option will cause the ping to be continuously sent Turn the SSE232 IA on The equipment will respond after a few seconds Once the SSE232 IA resp...

Страница 15: ...portunities to enter your password After that the console will be blocked for 5 seconds before allowing you to re enter the password 3 1 4 3 1 4 3 1 4 3 1 4 Serial Configuration Command Console Serial Configuration Command Console Serial Configuration Command Console Serial Configuration Command Console You can access the serial port command console by locally connecting the SSE232 IA to a compute...

Страница 16: ...E This parameter will be accepted upon execution of the END command At that moment communication with the equipment will be interrupted If you are not sure close communication without typing the END command _ To change the netmask netmask netmask netmask enter the following command netmask 255 255 255 0 Ok Netmask 255 255 255 0 NOTICE This parameter will be accepted upon execution of the END comma...

Страница 17: ...2 IA configuration command console is available on Port 998 Each COM socket connection can function either in Client Mode or in Server Mode 3 2 1 1 3 2 1 1 3 2 1 1 3 2 1 1 Server Mode Server Mode Server Mode Server Mode If a COM socket channel is configured to function in Server Mode listening in a user configurable port the device will wait for a client to establish a connection That is the clien...

Страница 18: ...the Supervision and Control Port 3 2 2 2 3 2 2 2 3 2 2 2 3 2 2 2 Configuration Password Configuration Password Configuration Password Configuration Password Both the TCP configuration console and the web page are protected by a password The device administrator may assign access key for these resources thus supplying safe access to SSE232 IA configuration To change the password through the Web pag...

Страница 19: ... may enable or disable the option of configuration through the web page by executing the WEBCFG command Table Table Table Table 6 6 6 6 WEBCFG command WEBCFG command WEBCFG command WEBCFG command Command Command Command Command Description Description Description Description WEBCFG E D Enables or disables configuration through web page E Enables D Disables 3 2 2 4 3 2 2 4 3 2 2 4 3 2 2 4 How to re...

Страница 20: ...ation page Click on the Reset SSE button A message will appear asking you to confirm the action Select Yes if you want to reset the SSE232 IA From the command console you may reset the SSE232 IA by executing the RE RE RE RESET SET SET SET command Table Table Table Table 8 8 8 8 RESET command RESET command RESET command RESET command Command Command Command Command Description Description Descripti...

Страница 21: ... to the serial protocol in use If the protocol you run on the serial side does not allow any delay time window should be configured to 0 Possible values for the time window range from 0 to 2000 milliseconds E E E End Character nd Character nd Character nd Character Indicates the last character of a pattern to form the packet If it is used together with a time window greater than 0 milliseconds whe...

Страница 22: ...ection will remain open even if no data is detected This feature can be configured independently for each channel through the Inactivity Timeout Inactivity Timeout Inactivity Timeout Inactivity Timeout parameter If this value is 0 the associated connection will not be shut down due to inactivity in that channel i e the feature is disabled Automatic Reset Automatic Reset Automatic Reset Automatic R...

Страница 23: ...r Mode Channel Configuration Server Mode Channel Configuration Server Mode Channel Configuration Any channel configured in Server Mode will be initially in a listen state waiting for a connection request on a given port user configurable If the connection is closed the device will return to the listen state waiting for a new connection on the same port In Server Mode the parameters for the channel...

Страница 24: ...COM x It is expressed in minutes After the close the socket returns to a listen state 3 2 6 3 2 6 3 2 6 3 2 6 Client Mode Channel Configuration Client Mode Channel Configuration Client Mode Channel Configuration Client Mode Channel Configuration In Client Mode each channel tries to connect to a specified server IP and port every 10 seconds Once the connection is established data is transparently t...

Страница 25: ...figures the mode associated to COM x To select Client Mode select C PORTx 1 65535 Client port associated to the COM x IPSERVx aaa bbb ccc ddd Server IP address to request a connection associated with the COM x PORTSERVx 1 65535 Server port to request a connection associated with the COM x INACTOUTx 0 10000 Maximum inactivity time allowed to this connection before it is closed due to inactivity ass...

Страница 26: ...rol digital inputs outputs and to supervise the status of connection sockets linked to every channel by simple commands The Supervision and Control Port works through a TCP connection in the port 999 Each command must end with the CR character ASCII 13 The system will answer whether each command has been successfully executed 3 2 8 1 3 2 8 1 3 2 8 1 3 2 8 1 Supervision of Connections Commands Supe...

Страница 27: ...SE232 IA model The IN command allows to know the status of one of the available inputs in each SSE232 IA model If you request an unavailable input the answer will be error Table Table Table Table 14 14 14 14 INA and IN command INA and IN command INA and IN command INA and IN command Command Command Command Command Description Description Description Description Answer Answer Answer Answer INA CR S...

Страница 28: ...ng a change in one of them If the automatic digital input report option is enabled SSE232 IA will inform the status of all the inputs when a client connects to the TCP Port 999 and every time a change in any of the available inputs is detected This option can be enabled or disabled according to your needs To enable or disable the automatic digital input report through the configuration Web page Se...

Страница 29: ...l You may select the transport protocol for the Ethernet interface Possible protocols are TCP TCP TCP TCP and UDP UDP UDP UDP The selection of the transport protocol affects all SSE232 IA channels Thus if you select the TCP protocol all the channels will use this protocol Similarly if you select the UDP protocol all the channels will use this protocol To change the protocol through the SSE232 IA c...

Страница 30: ...SERV 192 168 0 105 IP 192 168 0 108 UDP Client Channel IPSERV 192 168 0 105 E T H E R N E T A B A B A B A B Figure Figure Figure Figure 11 11 11 11 An SSE2 An SSE2 An SSE2 An SSE232 32 32 32 IA Client Broadcasts to all clients with IPSERV Fixed IP IA Client Broadcasts to all clients with IPSERV Fixed IP IA Client Broadcasts to all clients with IPSERV Fixed IP IA Client Broadcasts to all clients wi...

Страница 31: ... serial data to the Client s IP unless the client has previously sent a packet to establish communication In other words the SSE232 IA Server will have to receive a UDP packet from the client to be linked to that IP After that the data available at the serial port will be transmitted to the client s IP If the client fails to send a packet to the server the server will not be able to establish a li...

Страница 32: ... 168 0 105 PORTSERV 1001 RS 232 485 422 IP 192 168 0 106 RS 232 485 422 UDP Client Channel IPSERV 192 168 0 106 PORTSERV 1000 1001 1000 A B A B Figure Figure Figure Figure 13 13 13 13 Connection between two UDP clients Connection between two UDP clients Connection between two UDP clients Connection between two UDP clients ...

Страница 33: ... com The Device Locator application must be run on a PC connected to the same network where any Exemys device is to be configured Figure Figure Figure Figure 14 14 14 14 Exemy Exemy Exemy Exemys Device Locator s Device Locator s Device Locator s Device Locator When the Device Locator is run for the first time it will search any Exemys device within the network If there is an Exemys device in the n...

Страница 34: ...device founded by the Device Locator Select the device in the grid and click on the Properties button or open the Actions menu and select the Properties command You will see the Properties dialog box All Exemys devices provide a Remote Configuration Password This password is used for the Web configuration page and remote command Console in the device Enter this password in the Enter current passwo...

Страница 35: ...n Led Green Led Green Led Description Description Description Description It flashes alternately with Green Led It flashes alternately with the Yellow Led Critical failure It is steady on SSE232 IA is looking for a DHCP server on the network It is second on and second off SSE232 IA is waiting for an IP address configuration ping or the CFG command to be entered It blinks like a beacon 90 of a seco...

Страница 36: ...until you hear a Click B DIN Riel Click A B DIN Riel Figure Figure Figure Figure 15 15 15 15 Assembly of the device on DIN Assembly of the device on DIN Assembly of the device on DIN Assembly of the device on DIN rail rail rail rail To disassemble the device of the rail DIN figure 16 pull down the metallic clip and then remove it C C kd DIN Riel Figure Figure Figure Figure 16 16 16 16 Disassemblin...

Страница 37: ...C COM C COM D COM D COM D COM D IP 0 0 0 0 DHCP Netmask 0 0 0 0 Gateway 0 0 0 0 Protocol TCP Automatic Reset Enabled Web Configuration Enabled Digital Input Report Disabled Remote Configuration Password None Baud Rate 9600 Parity None Data Bits 8 bits End char Disabled Time window Disabled 0ms Mode Server Listen Port Server Mode 1000 1001 1002 1003 Server IP Address Client Mode 192 168 0 99 192 16...

Страница 38: ...equiring Ethernet access 3 5 to 28 Volts DC 1 to 11mA max High drive open collector 3 to 45 Volts DC 130mA max per channel Industrial plugabble terminal blocks HTTP Server password protected TELNET Console password protected Serial RS232 Console Downloadable via programming cable optional Status Led Data Link Led Power Led 4 49 x 3 94 x 0 89 in HxWxL 114 x 100 x 22 5 mm 0 31 Lbs 0 140 Kg 9 to 26 V...

Страница 39: ...SSE232 IA User s Manual Exemys www exemys com Rev 4 Page39 ...

Отзывы: