SSE232-IA User’s Manual
Exemys
www.exemys.com
Rev. 4
Page26
RS-232/485/422 (RS-485 and RS-422 available in COM A, model SSE232-1C4C-IA only).
Information received from the serial port is transmitted to all the clients located in the Ethernet
network.
SSE232 IA
SERVER
RS-232 / 485 / 422
ETHERNET
…
SSE232 IA
Client 1
SSE232 IA
Client 2
SSE232 IA
Client 3
SSE232 IA
Client 8
A
B
A
B
A
B
A
B
A
B
Figure
Figure
Figure
Figure 10
10
10
10 ---- Multidrop Mode: up to 8 clients
Multidrop Mode: up to 8 clients
Multidrop Mode: up to 8 clients
Multidrop Mode: up to 8 clients
3.2.8
3.2.8
3.2.8
3.2.8
Supervision and Control Port.
Supervision and Control Port.
Supervision and Control Port.
Supervision and Control Port.
The SSE232-IA allows to control digital inputs/outputs and to supervise the status of connection
sockets linked to every channel by simple commands.
The Supervision and Control Port works through a TCP connection in the port 999. Each command
must end with the CR character (ASCII 13).
The system will answer whether each command has been successfully executed.
3.2.8.1
3.2.8.1
3.2.8.1
3.2.8.1
Supervision of Connections Commands
Supervision of Connections Commands
Supervision of Connections Commands
Supervision of Connections Commands
You may supervise the connections by executing the STA
STA
STA
STA and RST
RST
RST
RST commands....
The
STA
command will allow you to know the connection status of a channel on the Ethernet
side by answering ‘1’ (Connected) or ‘0’ (Disconnected).
The
RST
command allows to reset the socket of a specified channel. If your command is related
to a socket of a channel that is not available on that model, the answer will be “error”.