SGW1-IA3-MB-NM – NMEA talker to Modbus slave Converter – User’s Manual
www.exemys.com
Rev.4
16
40122
Time (UTC)
-
-
40123
Receptor Integrity control (RAIM)
-
-
40124:5
Param[1]
-
Int 32
40126:7
Param[2]
-
Int 32
40128:9
Param[3]
Automatic
Int 32/ Float 32
40130:1
Param[4]
Automatic
Int 32/ Float 32
40132:3
Param[5]
Automatic
Int 32/ Float 32
40134:5
Param[6]
Automatic
Int 32/ Float 32
40136:7
Param[7]
Automatic
Int 32/ Float 32
40138:9
Param[8]
Automatic
Int 32/ Float 32
40150
Wind direction min (A#0)
-
-
40151
Wind direction average(A#1)
-
-
40152
Wind direction max (A#2)
-
-
40153
Wind speed min (S#0)
x10
-
40154
Wind speed average (S#1)
x10
-
40155
Wind speed max (S#2)
x10
-
40156
Rain accumulation (V#0)
x100
-
40157
Rain duration (Z#0)
-
40158
Rain current intensity (R#0)
x10
-
40159
Hail accumulation (V#1)
x100
-
40160
Hail duration (Z#1)
-
40161
Hail current intensity (R#1)
x10
-
40162
Heating temperature (C#2)
x10
-
40163
Supply Voltage (U#0)
x10
-
40164
Heating voltage (U#1)
x10
-
40165
3.5V reference voltage (U#2)
x1000
-
The SGW1 will use the “format 2” registers of it receives on the 3 following NMEA XDR
sentences. If it doesn’t match any of this it will use the XDR original format.