2  Wiring 

2.1  General Wiring 

 

MCV1-FO-SER wiring is very simple and intuitive. There are three different connectors. 
 

-

 

Serial port connector in industrial pluggable terminal block. 

-

 

Optic fiber port connector in ST type. 

-

 

Power supply Terminal block (+10 a +30 Vdc) 

 
First connect the device to an appropriated power supply, then the Serial port and finally the two Optic Fiber 
connectors (TX Transmitter and RX Receiver) 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Содержание MCV1-FO-SER

Страница 1: ......

Страница 2: ...roducts are in permanent evolution to satisfy the needs of our clients For this reason the specifications and capabilities are subject to change without previous notice Please find updated information at www exemys com Copyright Exemys 2009 All Rights Reserved Rev 4 ...

Страница 3: ... 4 3 Index 1 Introduction 4 1 1 Purpose of the manual 4 1 2 General Description of the product 4 2 Wiring 5 2 1 General Wiring 5 2 2 Standard Connection 6 2 3 Ring Connection 7 3 Configuration LED s 8 4 Technical Specification 9 RS485 Port Connection 10 ...

Страница 4: ...s instructions for the proper installation of its hardware Later on the manual includes detailed information for configuration and operation 1 2 General Description of the product The MCV1 FO is an Industrial Multimode Fiber Optic to Serial converter that allows to extend the communications up to 2 7 Km and without interferences for electrical noise The main features of the product are Industrial ...

Страница 5: ...ve There are three different connectors Serial port connector in industrial pluggable terminal block Optic fiber port connector in ST type Power supply Terminal block 10 a 30 Vdc First connect the device to an appropriated power supply then the Serial port and finally the two Optic Fiber connectors TX Transmitter and RX Receiver ...

Страница 6: ...el point to point This way it s possible to extend a serial connection up to 2 7 Km with all the characteristics of an optical fiber The use of the MCV1 FO also allows you convert the type of serial RS232 RS485 or RS422 that mean that you can connect to the equipment two different type of serial in each one of the ends of the tunnel ...

Страница 7: ...o use the type of serial RS232 RS422 that adapts to the equipment that goes connected on it with exception of the RS485 protocol this is because the ring mode receives and transmits simultaneously leaving the RS485 out for being a HALF DUPLEX protocol The data sent by the Master will be received and forwarded by all the slaves belonging to the ring Finally this data will arrive again up to the Mas...

Страница 8: ... data receive on the fiber RX Port will be transmitted to the serial port and forwarded to the fiber TX Port This way you can create an optical fiber ring This mode is not available for RS485 2 Serial communication mode RS485 or RS232 RS422 Enable disable the converter to use the RS485 or the RS232 RS422 Terminals Ring mode is not compatible with RS485 Mode LED s TX Blinks when data is sent to the...

Страница 9: ...erial Port RS232 RS485 RS422 Not simultaneous Fiber Optic Port Transmitter Receptor Fiber Optic Connector ST Power Supply 10 30 Vdc Power ON LED Case DIN Rail Mountable Fireproof Maximum Distance 2 7 Km Baud rate Up to 115200 bps Fiber Optic supported Multimode 50 125 um or 62 5 125 um Wave Length 850 nm Max Current 150mA 10V 75mA 30V ...

Страница 10: ...MCV1 FO SER User s Manual Exemys www exemys com Rev 4 10 ...