DC INPUTS:
"REMOTE" CONNECTION:
AC OUTPUTS:
230 VAC:
IEC-320
COOLING:
DC POWER ON LED:
LOW BATT / THERM BUZZER:
ON/OFF SWITCH:
OVER VOLTAGE PROTECTION:
A two-pole connector is provided under the rear
cover. The rear cover must also be removed to access this
connector. Use Appendix "A" to choose the appropriate gauge
wire for your specific model. A 2 pole female connector is provided.
is on the six-pole, plug-in connector,
located under the rear cover.
has one NEMA-15 outlet (standard wall receptacle),
located on the front panel. Additionally; may be hard-wired to
appliance / load using connections furnished on the six-pole, plug
-in connector, located under rear cover.
inverters have an
receptacle located on the
front panel.
convection cooled.
located on the front panel, will be "ON" when
inverter is powered up and DC power is available.
produces an audible alarm if DC
input voltage falls to a level within 2% to 4% of the low limit of
inverter, or, if there is an over temperature condition.
located on front panel; turns the inverter on and
off.
If input voltage to the inverter
exceeds set limits, the inverter will immediately shut off without
warning. When input voltage returns to normal range, the inverter will
.
.
.
.
.
.
.
S
tandard Features
2.0