background image

22

PRESETS and other functions.

The dome  has  up  to 32  presets  that  once programmed  with  stay  in  the domes  non-volatile  memory  so  they

will be retained even after a power cut.

What is a preset? A preset is a particular area or object that the dome was looking at and has been stored into

its memory so when the preset is “called-up” the dome will select the area again without the operator using

the joystick to do this. This means that you could for example store a PRESET of a car-park entrance. When

the  operator  calls  up  this  preset  the  dome  automatically  moves  to  this  location.  By  storing  more  than  one

preset you can add even more functionality to the dome. By having two presets, you can then get the dome to

“SCAN” between the two locations.

Having 3 or more presets you can get the  dome to go on a TOUR (PATROL) of the presets. When  you run

the  patrol  the  dome  goes  to  one  preset,  then  waits  a short  period  then  on  to  the  next  preset  and  so  on.  The

dome  continues  to  cycle  around  this  patrol  until  you  cancel  it. The  length  of  time  the  camera  stays at  each

location is set in this dome at 4 seconds and the speed of travel between each preset point is 7.5

°

 per second.

In the dome some preset numbers are reserved for special functions, these are listed as follows;

What you press at the keyboard

PRESET

No.

Special function

Press

 XX then CALL

(XX = preset No)

Press

 XX then PRESET

(XX= preset No)

51

Starts an Auto Scan

Starts a TOUR

52

-

The location the Auto Scan
starts from.

53

-

The location the Auto Scan
ends at

If you wish to use the Auto Scan function YOU MUST FIRST USE preset 52 as the starting point of the scan

and preset 53 as the ending point of the scan.

PRESETS -How to set up a preset

Aim  the  dome  where  you  want  it  to  look  and  zoom  in  or  out  to  get  the  correct  scene.  Now  press  the

following keys on the keypad :

xx PRESET

(where

xx

 is the preset number you wish to store). For example

01  PRESET  would  store  PRESET  01  and  the  camera  would  always  go  to  this  location  when  01  is

“CALLED”.

Ensure that you do not keep the preset button depressed, as this will delete the preset.

To test if the preset is stored correctly use the joystick to move the camera to a point in a new location. Now

press

xx CALL

 (where

xx

 is the preset you wish the camera to go to). In this example if you press

01 CALL

the dome should go straight to the PRESET 01 location.

TIP -You may wish to write down a list of presets that you have stored next to the keypad for the operator.

Auto Scan / Tour

Auto Scan

Auto Scan

Содержание PTZ200

Страница 1: ...Installation and Operation Manual Economic PT Dome 12vDC Models covered PTZ200 Version 1 For updates to these instructions visit www excelPTZ com the excelPTZ range...

Страница 2: ...Powering the domes 13 RS485 connection Connecting the Keypad or DVR to the Dome 14 Connecting the video out of the dome 15 Setting the PTZ dip switches 17 Setting up a unique address in a dome 18 Set...

Страница 3: ...high voltage equipment such as mains cables and especially fluorescent lights Using an anti surge protection device is recommended to prevent damage to the domes from lightning and mains surges Damag...

Страница 4: ...our option Description of Functions 1 Integrated Multi Protocol Decoder The integrated multifunctional decoder can communicate with 5 different protocols The baud rate can be independently set allowin...

Страница 5: ...the comfort of your own premises Overview introduction to fitting PTZ equipment Generally speaking PTZ Domes requires four things 1 They require a power supply and a cable to supply this power to the...

Страница 6: ...idering using baluns please note DVR s tend to require very good video signals to function correctly and passive baluns can loose some signal strength over the 50 metre mark so try to restrict the use...

Страница 7: ...ards RS485 is a half duplex data transmission type with characteristic impedance of 120 The maximum load capacity is 32 units domes keyboards and DVRs 2 Transmission distances of RS485 Signals using C...

Страница 8: ...eliability so that the domes function as expected A common mistake installer s make is not making sure the 120 resistor is switched ON in the LAST dome Also installers often select the resistor to ON...

Страница 9: ...is connected and when the jumper is set between positions 2 and 3 the resistor is not connected JP1 1 2 2 3 120R O N O FF O N DI P 1 2 3 4 5 6 7 8 9 10 O N DI P 1 2 3 4 5 6 JP1 1 2 2 3 120R O N O FF J...

Страница 10: ...dome s movements are tiny signals that can get corrupted for many reasons Poor cable quality not using a PAIR of cores from a CAT5 but using one core from TWO separate pairs running the CAT5 cable ne...

Страница 11: ...ne dome on each spur from the PTZ750 but up to 4 domes is generally acceptable The following diagram shows a typical use of the PTZ750 RS485 distributor In the following example and diagram domes 1 4...

Страница 12: ...a good idea what your options are Below is a general schematic diagram showing you some of these options PTZ DOME 12V DC CAT 5 CAT5 Carries Video Control Data CCT CAMERA Video Power TRADITIONAL CAMER...

Страница 13: ...a 2 1mm mini jack socket connected Connect a suitable 12V D C power supply with a mini jack plug The BNC connector is the VIDEO OUT from the camera and goes to the monitor or VIDEO IN of a DVR camera...

Страница 14: ...have done this it is just a job of extending the cables and physically installing the domes on site You must obviously take note of the RS485 wiring techniques mentioned at the beginning of these ins...

Страница 15: ...ld always take your test monitor to your PTZ dome and check the picture quality on its own short BNC lead If you re testing the equipment on a workbench you now have a one dome system You can use a ke...

Страница 16: ...16 12V DC INPUT RS485 A ORANGE RS485 B YELLOW RS485 INPUT ON DVR PSU CAT5 Data cable RG59 Video Cable Power Cable 12V DC...

Страница 17: ...then the default address of 1 is okay and you have no reason to change the dome from this With multiple dome sites you need to set up each dome address separately This is accomplished by setting the S...

Страница 18: ...IP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 DIP 9 DIP 10 1 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF...

Страница 19: ...1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 SAMSUNG ON OFF OFF OFF OFF ON B01 ON OFF OFF OFF OFF ON PELCO D ON ON OFF OFF OFF OFF PELCO P 4800 ON OFF PELCO P 9600 OFF OFF ON OFF OFF ON ALEC OFF ON ON ON OFF ON Ta...

Страница 20: ...sed to select the baud rate of communication and a maximum of 4 different baud rates can be selected If the controller adopts a non standard baud rate you can adjust it to be identical with that of th...

Страница 21: ...rotocol protocol D or P The current camera address each P T device requires a unique address 1 32 The current baud rate To set up the keyboard to the correct settings for this dome do the following TI...

Страница 22: ...point is 7 5 per second In the dome some preset numbers are reserved for special functions these are listed as follows What you press at the keyboard PRESET No Special function Press XX then CALL XX...

Страница 23: ...limits of its scan To start an Auto Scan press 51 CALL TIP To stop the scan just move the joystick slightly Patrols Tours How to set them up and use them A patrol tour is simply a collection of at lea...

Страница 24: ...that the preset has been deleted For example to delete preset 1 press 01 PRESET holding the preset button for 3 seconds Obviously if you wish to overwrite a preset with a new location simply aim the c...

Страница 25: ...lation Instructions Dimensions 130 60 100 R67 5 5 Dimension of shell Ceiling mount board Installation a Ceiling mount PO W ER PO W ER D C12V O range O range R S485 Yel l ow Yel l ow R S485 VID EO VID...

Страница 26: ...26 b Suspended installation 300 7 Fixed bracket Orientation aperture 130 86 40 Suspended installation board a Wall mount 3 Wall mount board...

Страница 27: ...his is used for installing the dome cable housing and hiding the connection cable 2 Take out the two fixed Allen screws using the specialAllen key t ake of f Screw on 3 Due to the two rubber waterproo...

Страница 28: ...ud and push the unit into the metal shell and refit the screws 6 Hide the cable in the ceiling aperture and fix the dome to the ceiling 7 Ensure the video power and data cables are connected as per in...

Страница 29: ...2 Remove the ceiling installation board and replace with the wall installation board feeding the connection cable across the front on the bracket through the cable aperture 3 Fit the dome to the wall...

Страница 30: ...30 5 Correctly fit the connection cable...

Страница 31: ...Specifications Waterproof standard IP66 Horizontal Resolution 380 TVL 470 TVL enhanced Signal Noise ratio 52db min 60db TYP AGC OFF Digital zoom x2 Optional Electronic Shutter 1 50 1 120000sec Lowest...

Отзывы: