21
3.13.4 Setting Restriction Item B
Format:
4 2 Q ABCD#
Explanation:
ABCD: the initial digits of the calling number to be locked, it
can be from 1-digit to 4-digits, it should be ended with # if less than 4-digits.
Q --- The group series from 01 to 16.
Description:
to restrict the call-out number starting with ABCD
Example:
Ext.606 is be assigned dialing-out class 5, now you want
Ext.606 can’t dial the numbers with initial digits – 575,161
1. Item B can lock 16 groups of initial digits.
2. Restrict Item B only works for dialing-out class 5.
3.13.5 Clear Restriction Group of Item B
Format:
42 Q #
Explanation:
Q: The group series from 01 to 16.
Description:
to clear the call-out restriction of certain numbers of group Q.
3.13.6 Clear All Restriction of Item B
Format:
4 2 #
Description:
to clear all the call-out restriction of certain numbers of item B
3.14 Assign Special Calling-out Number
3.14.1 Assign Special Calling-out Number for Class 0
Format:
4 3 P ABCD#
Explanation:
ABCD: the initial digits of the calling number to be locked, it
can be from 1-digit to 4-digits, it should be ended with # if less than 4-digits.
P --- The group series from 01 to 16.
Description:
Permit to dial the phone numbers starting with <ABCD> only.
Example:
Ext.605 is be assigned dialing-out class 0, now you want
Ext.605 can dial the numbers with initial digits – 0592,179
1. 16 groups of initial digits can be set.
2. This function only work for dialing-out class 0.
Содержание MK-208