background image

Model

Scanning beams

Detecting

Response time

Displacement at 0mm

Adaptive environment

Size (mm)

System Hint

E-2000

154 beams

0 ~ 4000mm

< 90ms

Vertical:

20mm; Horizontal:

3mm

+

+

Light immunity

100000 lux

>

9 X 24 X 2000

1. The green LED on the Receiver indicates the

normality of the sensors.

Slow flashing means it is in condition of timeout.

2. The red LED light in the Receiver indicates the

states of the sensors.  If it is off, that means the
sensor is normal; If it is on or flashing, that means
the light curtain is obstructed or it arises errors.

1) Specification of Transmitter (TX) and Receiver  (RX):

Control Box

External Dimension

Material

Input Voltage

Relay Output Type

Power Consumption

Lifetime of Relay

Short Circuit Protection

System Hint

(Buzzers are optional)

P220-S (With Buzzer)

178mm X 67mm X 39.5mm

Steel & Aluminium

185-300V AC, + 10%, 50/60 Hz

COM, 1NO, 1NC

4VA

250VAC, 7A or 30VDC, 7A

> 1000000 times

YES

Give buzzer sound once interrupted.

Relay Contact Rating

2) Specification of Control Box (Power Supply):

Phenomenon of Fault

No response in RX (LED)

LED green light in RX is

flashing slowly and regularly

Faults Analysis

Cables no connection; or control box no power;

or cables were snapped

System is in status of timeout; or the broken

diode will be ignored.

6) Faults Comparison Table:

Check if there are other infrared equipments

around; if the windows of TX and RX are dirty;

if the windows are shined by glare; if the

cables are bad, or the light curtains damaged.

The light curtain is not

obstructed, but both the

LED green and red lights in

RX are on.

LED lights in RX are normal, but

the door doesn"t open although

the light curtains are obstructed.

Red indicator light in Control

box is off.

When the door is closing, the

doors jump and re-open.

Wrong  connection of control box, or relay output

is damaged, or the triode in RX is damaged.

Wrong  connection in control box, or no power; or

connection is not tigtt; or control box damaged.

Not reasonable when wiring; or conductive

earth of the control box is not well

Item number

Item Name

7) Packing List:

Quantity

Control box

Cable (4m)

Transmitter (TX)

Receiver (RX)

Instruction book

25mm X 25mm cable clip

M3 X 25 Screw

M3 Nut

90mm Nylon ties

1.

2.

3.

4.

5.

6.

7.

8.

9.

1 PC

2 PC

1 PC

1 PC

1 PC

6 PC

10 PC

10 PC

6 PC

E L E C T R O N I C S

Tel.:

Fax.:

+91-22-21029911

+91-22-21029922

!

!

!

E-mail:

Web:

[email protected]

www.excellaelectronics.com

OPERATING MANUAL FOR DOOR SENSOR

Отзывы: