3-1     

 Check Weighing Configurations 

 

    If hold mode is set, accessing to 

 

 

is denied.

 

 

Use 

 or 

 

key to select F4 function 

 

the display shows   

     

 

 

 

   

.

   

 

 

kg

 

 

 

.

 

 

   

kg

 

 

 

.

 

 

 

 

kg

 

 

 

.

 

 

   

kg

 

           

   

 

 

   

kg

 

                 

 

 

   

kg

 

 

 

E.g. LO value = 2 kg

Preset “LO value” 
 (LO value 

>

 10d) 

Press 

 and 

 

key to set “ LO value” 

Press 

 key 

E.g. HI value =2.5kg

Preset “HI value” 
 (HI value 

 LO value) 

Press 

 and 

 

key to set “ HI value” 

Press 

 key 

E.g.

Beeper

 value=22

 

Preset “Beeper value” 

Press 

 and 

 

key to set “Beeper value” 

Press 

 key 

 

 

.

 

 

   

kg

 

Press 

  key for 5 

times to clear HI, OK, 
LO values

 

Press 

 key 

 

 

 

key = Increase the flash value by one (0 ~ 9) 

 

key = Confirm key

 

                     

Χ

   

Χ

 

 

 

A

   

 0 = After stable, the beeper beeps and the 

indications are on 

1 = After stable, the beeper beeps; whether 

stable or not, the indications are on 

2 = whether stable or not, the beeper beeps   

and the indications are on. 

3= open warning device: when the weight is 

higher than HI value and the weight is stable,
LCD is on and Relay Card open. 

 0 = No beep 

1 = OK (when the weight is between Low limit & 

High limit.), the beeper beeps. 

2 = When the weight is under or equal to Low 

limit (must be over 10d) & over or equal to 
High limit, the beeper beeps. 

 LCD indication description: 

Ñ

 

 

Ò

   

Ñ

 

 

Ò

   

Ñ

 

 

Ò

 

ÕÕÕ

ÕÕÕÕ

     

ÖÖÖÖ

ÖÖÖ

 

10d  Low limit value  High limit value

 

Press 

 key 

Содержание ZSME300000240

Страница 1: ...n is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission Th...

Страница 2: ......

Страница 3: ...RATION DESCRIPTION 7 2 1 UNITS SELECTION ONLY FOR THE MODEL 5KEY 7 2 2 ZERO FUNCTION 7 2 3 TARE FUNCTION 7 2 4 NET GROSS FUNCTION 7 2 5 BACKLIGHT FUNCTION 8 CHAPTER 3 GENERAL FUNCTION SETTING 9 3 1 CH...

Страница 4: ...40 8 Any suggestion is warmly welcome Preparing to Use the Scale 1 Locate the scale on a firm level surface free from vibrations for accurate weight readings Adjust the four leveling feet to centre th...

Страница 5: ...de 3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized...

Страница 6: ...rder to keep the system stable When battery voltage is lower than system voltage the system will cut the power off automatically to ensure its stable and accuracy 8 LED BACKLIGHT 1 2 Display Descripti...

Страница 7: ...his key to select the required unit from the preset units 1 4 Power Description Power Selection 1 6 V 4 Ah Rechargeable battery 2 110 V 220 V 15 AC Recharge Voltage 1 AC 110 V 10 15 2 AC 220 V 10 15 P...

Страница 8: ...charged before operating again Please recharge at once when the symbol shows in order to keep the weight accuracy 1 5 Error Messages Weight exceed 9d of maximum capacity d division Zero value after po...

Страница 9: ...dication 6 is on Place goods into the container then the scale shows the net weight of goods When removing the container and goods the display shows the negative weight value of the container Then pre...

Страница 10: ...lay shows BL on and backlight off mode The display shows BL oFF Method 2 Press the hide key in order to select auto backlight mode backlight on mode and backlight off mode Auto backlight mode BL Auto...

Страница 11: ...figuration setting mode and is showed on the display Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Press key Reserve...

Страница 12: ...to clear HI OK LO values Press key key Increase the flash value by one 0 9 key Confirm key A B A 0 After stable the beeper beeps and the indications are on 1 After stable the beeper beeps whether stab...

Страница 13: ...e Press key to transmit in complete mode Stable transmission in totalizing mode The format is as same as Refer to F14 Refer to F14 Press key to transmit The format is as same as and Continuous transmi...

Страница 14: ...ansmission Press key to transmit 1 gram as weight unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g HEAD HEAD DATA UNIT CR LF 2 kg or lb as weight unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 kg l...

Страница 15: ...xamples Data format for RS 232 continuous transmission are as below 1 The gross weight 0 876 kg shows as below after stable under tare mode S T G S 0 8 7 6 k g 0D 0A HEAD1 HEAD2 DATA UNIT C LF 2 The n...

Страница 16: ...005 1 0000 Press 0005 5 0000 Press twice to print TOTAL Press key to transmit complete mode 4 key serial Press Press Press twice to print TOTAL TICKET NO 0001 G 1 000kg T 0 000kg N 1 000kg 3 blank lin...

Страница 17: ...f there is only RS232 press key to print out the HOLD value on display in HOLD MODE Continuous Transmission specific form The print out is as below If display shows 70 15kg the number RS 232 export is...

Страница 18: ...200 20 000020001000000020 P1 1 Use key twice to clear the format Then form of clearing the printing F R 5 LF LF TN TN TN TN TN TN LF TW TW TW TW TW TW LF TA TA TA TA TA TA LF tn tn tn tn tn tn LF tn t...

Страница 19: ...40 3 3 Exit Setting Mode Use or key to select F6 function the display shows 3 4 Internal Value Display Mode Use or key to select F7 function the display shows Press key Counting down to zero and exit...

Страница 20: ...fter about 1 second After about 1 second The screen displays last revised times and then displays local G value after about 1 second The screen displays the first two revised times and then displays l...

Страница 21: ...g shows as below after stable no tare or under pre tare mode 1 0 S T G S 0 0 0 8 7 6 k g 0D 0A ID HEAD1 HEAD2 DATA UNIT C LF 2 e g Machine ID code is 00 Not using Machine ID function The net weight 1...

Страница 22: ...print current weight if weight variation is within 1d 10d or to print accumulated weight if weight variation is over 10d d division Press key to print the current weight at once no totalization Press...

Страница 23: ...PT No 5 N No 6 P N No 7 S N No 8 No print No 9 No print Contains a 9 digit code If is set as n The format of is as following S N WT UNIT kg lb 0001 1 0000 Press key 0002 1 0000 Press key 0003 1 0000 P...

Страница 24: ...N WT UNIT kg lb 0001 1 0000 Press key 0002 1 0000 Press key 0003 1 0000 Press key 0004 1 0000 Press key 0005 1 0000 Press key 0005 5 0000 Press key twice to print the total o The format of is as follo...

Страница 25: ...ELL PRECISION CO LTD 02018058 23 ZSME300000240 Appendix 1 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y...

Отзывы: