![Excell PWH3 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/excell/pwh3/pwh3_user-manual_2449518041.webp)
EXCELL PRECISION CO., LTD
02005159 ZSME300000225
40
˙
Read weight comparison setting value
RS
: Groups(00 ~ 09)
: Setting Items
HI
Show “HI” presetting value
LO
Show “LO” presetting value
Note :
(Group) is various depended on different models
00
The first group
01
The second group
02
The third group
EX:
RS02LO
<
CR
><
LF
>
Show “LO” presetting value
ANS:
RS02LOXXXXXX
<
CR
><
LF
>
Command Format C
Host
Data
Slave
Data
Write weight comparison setting value
WS
XXXXXX
: Groups(00 ~ 09)
: Setting Items XXXXXX: Setting Value
HI
Write “HI” setting value
LO
Write “LO” setting value
Note :
(Group) is various depended on different models
00
The first group
01
The second group
02
The third group
EX:
WS00HI001000
<
CR
><
LF
>
Write “HI” setting value
ANS:
WS00HI001000
<
CR
><
LF
>
Command Format D
Host
Data
Slave
Value (e.g. Price)
Position of decimal point
CR
LF
1
2
3
4
5
6
1
When the Slave receives this data format, it will transfer the data and display it on its LCD.
The function is effective when the weight value is over 0.
The above 4 (ABCD) command formats are RS232 bi-directional. There are the
following error messages received by Slave terminal (scale).
Error messages:
E1: Wrong command
E2: Command format error (Wrong parameters)
E3: Command not recognised