03004035 21 ZSME200000058
EXCELL PRECISION CO., LTD.
Previous setting
Previous setting
1
1
Exit
1
CE
Move cursor leftward
1
T
Move cursor rightward
1
MC
Enter
3-1-9 Pre-tare mode setting
Press
MC
key
Enter parameter 00~01
Press
MC
key to
save the setting
Default setting:
.
Traditionally, pre-tare can not proceed when weight on platter. When no weight on
platter, press
T
key to enter pre-tare value and then press
T
key again.
Pre-tare can proceed when weight on platter. (Enter value in
UNIT WEIGHT
and
press
T
key.)
Pre-tare value can not be more than max. weighing value, or first and second segment point
of division; besides, the value can not be less than or equal to the external value set up in
FnC 06.
3-1-10
“Beeper” Output Setting for Quantity Limit
Press
MC
key
Enter parameter 00~01
Press
MC
key to
save the setting
Default Setting:
Non-approval
models
; Approval models
If the quantity exceeds quantity setting (or weight
exceeds weight setting), the beeper beeps in unstable situation.
If the quantity exceeds quantity setting (or weight
exceeds weight setting), it
’s no need to be stable
and the beeper beeps automatically.