Chapter 2 Operation
2-1 Power On
Press
ON/OFF
key to turn on the scale
WEIGHT
UNIT WEIGHT
QUANTITY
After stable, the scale will count back to zero.
WEIGHT
UNIT WEIGHT
QUANTITY
600
⇒
Maximum countable data: 600 000 Sampling Speed
After return to zero and being stable, scale will enter into counting mode.
2-2 Relatively Internal Value Display
After press
Z
key, screen will show “ - - - - - - ”. Press
CE
key.
WEIGHT
UNIT WEIGHT
QUANTITY
X X X X X
X
X X X X X X
Max internal calibration SP value is 5 digits Max internal value is 7 digits.
Press
0
key to return to the counting mode.
2-3 Zero Function
While operating the scale, zero may sometimes fluctuate. (Slight weight changes happen in
weight column.) Press
Z
key to return to zero.
2-4 Sampling Function
2-4-1 Unknown Unit Weight of a Weighed Object
1. Place the sampling object on platter
.
Weight on platter
2. Enter the quantity of the sample on platter
.
Weight on platter Enter the sampling quantity
The number of quantity column will flash 6 seconds. If the user doesn
’
t press the
SMPL
key before flashing is over, the scale will complete the unit weight setting procedure
automatically after flashing. The scale will also take the number that inputted in unit weight
column as the unit weight of object to calculate the quantity of object shown in quantity column.
3. Press
SMPL
key while total column number is flashing
.
Weight on platter