background image

 

 02026010  

                                                                                                                    

ZSME300000369 

EXCELL PRECISION CO., LTD.     

 

Chapter 2 Advanced Functions 

2-1 Advanced Function Setting Table 

Below is an overview of the advanced functions.  For detailed settings refer to the following 
sections: 
 

DISPLAY 

LEVEL 1 FUNCTION 

DISPLAY 

LEVEL 2 FUNCTIONS 

           

Exit the 

ADVANCED 

FUNCTION

 setting mode 

--- 

--- 

            

 

General Function setting 

mode 

     

  

   

Return to 

ADVANCED 

FUNCTION

 setting menu 

     

  

   

Automatic backlight 

function setting 

     

    

 

Automatic power-off  

timer setting 

     

    

  Hi/Lo/OK function setting 

     

    

 

Restore the default 

settings 

     

    

 

Noise filter setting 

   

     

 

Hold function setting 

   

     

 

Auto unit weight 

averaging setting 

   

     

 

Two Weighing Units 

Setting 

   

     

 

Unstable Tare 

 

          

External Weight 

Calibration 

--- 

--- 

 

 

 

 

 

 

 

 

Содержание ELW Max

Страница 1: ...ned herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written per...

Страница 2: ......

Страница 3: ...1 ADVANCED FUNCTION SETTING TABLE 8 2 2 ADVANCED FUNCTION SETTING WORKFLOW 9 2 3 GENERAL FUNCTION SETTING 10 2 3 1 Automatic Backlight Function Setting 11 2 3 2 Automatic Power off Timer Setting 12 2...

Страница 4: ...ssible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the scale 4 Remove any weig...

Страница 5: ...n point for transportation Low power indication and auto power off Specifications Model Capacity Division Resolution ELW Max 3 ESW Max 3 3kg 0 5g 1g 1 6 000 1 3 000 ELW Max 6 ESW Max 6 6kg 1g 2g 1 6 0...

Страница 6: ...t weight is not sufficient When the icon is on the counting function is operational but the count may contain errors The sampling size is not sufficient When the icon is on the counting function is op...

Страница 7: ...le are dependent on the exact scale model After power off the scale will memorize the active units When the scale is powered on again it displays the previously active units TARE FUNCTION 1 Put a cont...

Страница 8: ...r the arrow pointing to the icon will be on When the or are indicated the scale is still operational but the count may contain errors To power off in this mode the scale will memorize the Pcs unit Whe...

Страница 9: ...TARE to enter and the display shows internal value Please check whether the internal value has changed obviously with weight changing Please check the backlight Press ON ZERO key to back to the last...

Страница 10: ...VEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode General Function setting mode Return to ADVANCED FUNCTION setting menu Automatic backlight function setting Automatic p...

Страница 11: ...Function setting mode The LCD shows Overall workflow of the Advanced Function setting mode General Function setting mode External Weight Calibration Exit the Advanced Function setting mode Refer to th...

Страница 12: ...e Default Settings Noise Filter Settings Hold Function Settings Auto Unit Weight Averaging Setting Two Weighing Units Setting Unstable Tare Refer to the following sections for detailed operation proce...

Страница 13: ...n the scale is idle near zero 10d without any key being pressed for 10 seconds it will automatically disable the backlight To activate the backlight place weight over 10d or press any key DISPLAY ACTI...

Страница 14: ...RO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROSS key Move the cursor to left Automatic power off timer setting Use ON ZERO or UNITS key to k...

Страница 15: ...setting a b c The definition of a b c positions a 1 beep sound on 0 beep sound off b 1 beep sound on when stable 0 beep sound on when unstable c 1 beep sound on when the weight is between high and low...

Страница 16: ...the counting function If is set to and the scale has not been restarted automatically Please ensure to restart the scale manually ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the defa...

Страница 17: ...Filter parameter setting LCD displays the last saved parameter setting Filter parameter setting Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number...

Страница 18: ...able the LCD shows the current weight value When the weight returns to zero 10d the hold mode is cancelled automatically ACTIONS DISPLAY NOTE Hold function setting Use ON ZERO or UNITS keys to key in...

Страница 19: ...ey from 9 to 0 TARE key Move the cursor to right NET GROSS key Move the cursor to left Auto unit weight averaging setting Use ON ZERO or UNITS keys to key in the parameters Default setting 0 0 Auto un...

Страница 20: ...vate two weighing units please set the 2nd weighing unit to be 1 2nd weighing unit in CSP 01 2 3rd weighing unit in CSP 01 3 4th weighing unit in CSP 01 If it set to 1 3 it only displays the 1st weigh...

Страница 21: ...tting 0 0 Disable tare operation while unstable 1 Enable tare operation while unstable Unstable Tare setting LCD displays the last saved parameter setting ON ZERO key Upward key from 0 to 9 UNITS key...

Страница 22: ...of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LCD shows the calibration weight value Press T...

Страница 23: ...on the setting in FnC08 Command Format B Host Command Slave Data RG Read Gross weight RN Read Net weight RT Read TARE Note add before the command to read continuously Read HIGH LOW values in FnC 03 R...

Страница 24: ...e RS232 bi directional The following error messages might be received by Slave terminal scale Error messages E1 Wrong command E2 Command format error Wrong parameters E3 Do not match with the executin...

Страница 25: ...26010 ZSME300000369 23 EXCELL PRECISION CO LTD Appendix 2 7 Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y...

Отзывы: