background image

E X C E L   D R Y E R ,   I N C           1 . 8 0 0 . 2 5 5 . 9 2 3 5           E X C E L D R Y E R . C O M           A D M I N @ E X C E L D R Y E R . C O M

3 5 7   C H E S T N U T   S T R E E T,   E A S T   L O N G M E A D O W ,   M A   0 1 0 2 8

0 2 / 2 0 1 6

2

R E A D  A N D   S AV E   T H E S E   I N S T R U C T I O N S

W ARNING :  

F o r  p r o p e r  e l e c t r i c a l  c o n n e c t i o n s ,  c h e c k  y o u r  l o c a l  b u i l d i n g  c o d e s .  

Your unit must be installed by a qualified, licensed electrician.

P RE INSTAL L ATION W IRING

• Check that the electrical supply corresponds to that shown

on the rating sticker of unit. If the dryer is connected to any  

electrical supply other than that stated on the rating sticker of 

the unit, permanent damage or improper, unsafe operation of 

the unit may result.

• Make sure electricity is switched off at the main panel before

installing, maintaining or cleaning this hand dryer. Dryer must 

be installed in accordance with current local wiring and  

building regulations.

• Do not wire this hand dryer into the lighting circuit. It must be

protected by an independent circuit.

• Dryer is intended to be permanently connected to power

supply, and must be properly grounded.

SAF ETY

• Troubleshooting and internal maintenance must be performed

by qualified service personnel.

• Do not use any power wash equipment for cleaning on or

near this unit.

• Do not use the XLERATOR dryer for drying hair.
• Do not obstruct air inlets or outlets.

1.  Disconnect the power source previously brought to the hand

dryer location (see pre installation wiring above).

2. Use the Tamper-Proof Wrench supplied to remove the 2

cover mounting screws and lift cover to remove from base 

  plate.
3. If electrical wiring entry is to be made from the rear, remove

the appropriate pre-formed knockout on the base plate. If 

entry is to be made from the bottom, knock out the  

pre-formed area on the cover for your supply connection.  

A rigid conduit must be used.

4. Select the appropriate mounting height for dryer (Table 1)

and fastener, as recommended (Table 2). There should be  

no obstruction between the hand dryer and the floor. If  

mounting over a countertop, distance from counter to dryer 

must be 15” (381 mm) minimum.

CAUTION:

 Do not use Base Plate as a guide when drilling. 

Make sure no pipe work (gas, water, air) or any electrical cables 

or wires are located directly behind the area to be drilled. 

5.  Attach Base Plate at the four corners to smooth wall.

For most secure installation, use 2 additional mounting holes 

as shown in drawing. For non-HEPA units, remove Control 

Assembly to access the right side mounting hole.  

For HEPA units, remove filter only to access the right side 

mounting hole.

6. Identify the voltage of your dryer from the rating sticker of the

unit. Then connect to a dedicated branch circuit not

exceeding 20 Amp.

7. Secure electrical wiring to terminals as indicated by the

schematic affixed to blower housing. An identified ground

connection point is supplied on the Base Plate for your

equipment ground wire. Dryers should be installed per local

code requirements.

8. Carefully replace Cover using the 2 screws previously

removed in step 2. Restore power and test for proper

operation. In multiple installations, make sure the serial

number marked on the inside matches the cover number.

9. It is highly recommended that a bead of silicone sealant be

placed around the outside of the cover at the wall to protect

dryer from internal corrosion caused by wash water and

cleaning solutions.

10. Return Tamper-Proof Wrench 

a d 

er   a al 

to owner.

SUG G ESTED M OUNTING  HEIG HT

 

from floor to bottom of dryer:

Men 

45" (114 cm)

Women 

43" (109 cm)

Teenagers 

41" (104 cm)

Small Children 

35" (89 cm)

Handicapped 

37" (94 cm)

M OUNTING  HARDW ARE

Re c o m m e n d e d  F a s t e n e r  

(not supplied):

Masonry Wall 

½” Expansion Sleeve with ¼” Lag Bolt

Hollow Wall 

¼” Wing Type Toggle Bolt

Wooden Wall 

¼” Lag Screw With Washer

1

2

INSTAL L ATION INSTRUCTIONS

TABLE 1

TABLE 2

IM P ORTANT SAF ETY  INSTRUCTIONS

ADJUSTING THE HEAT OUTPUT AND MOTOR SPEED

The dryer is shipped set at maximum heat and motor speed.  

To adjust, turn the corresponding knob (H=heater, M=Motor) 

on the control assembly counterclockwise to desired setting.

Отзывы: